    • Application of Modified EcoScreen Condenser in Ventilated Patients for Collecting Exhaled Breath Condensate

      Objective To investigate the feasibility of collecting exhaled breath condensate ( EBC)fromartificially ventilated patients with modified EcoScreen condenser. Methods ①In vitro test with lung simulator: the modified EcoScreen condenser was connected to lung simulator and mechanically ventilated for 60 min through three different types of connected tube as follows: dry ventilator pipe disconnected to humidifier, connected to the unheated humidifier, and connected to heated humidifier.Meanwhile, the changes of the peak pressure of inspiration ( PI) and tidal volume ( VT ) were observed. The volume of condensate was measured at last. ②In vivo test from artificially ventilated patients: 10 patients were artificially ventilated and their EBCs were collected with the modified EcoScreen condenser through dry pipe disconnected to humidifier for 20 min. The changes of PI, VT , respiratory frequency( f) , heart rate( HR) , mean arterial blood pressure ( MAP) , and blood oxygen saturation ( SpO2 ) were observed. Results ①In vitro test with lung simulator: At the end of the ventilating through the dry pipe disconnected to humidifier for 60 min,2. 2 mL condensate wascollected. Neither the change of PI or VT nor the obstruction of the collecting tube by iced condensate were observed. The ventilating through dry pipe connected to unheated humidifier had to stop at 50 min as the obstruction of the collecting tube caused by ice. 5 mL condensate was collected. It was observed that VTdecreased and PI increased. After ventilation through dry pipe connected to heated humidifier for 60 min,10. 5 mL condensate was collected while PI slightly increased and VT decreased. ② In vivo test from artificially ventilated patients: After ventilation through dry pipe disconnected to humidifier for 20 min, 2 mL EBC was collected without significance changes in PI, VT, f, HR, MAP, and SpO2 . Conclusions The modified EcoScreen condenser can be favourably applied to artificially ventilated patients for collecting EBC.It is recommended to performfor 20 min through the pipe disconnected to humidifier to obtain sufficient EBC without condensate dilution and airway obstruction. It is warranted more attention to the clinical and mechanical monitoring in this procedure.

      Release date:2016-08-30 11:53 Export PDF Favorites Scan
    • Annual result of retinopathy of prematurity screening in Shanghai area

      Objective To investigate the incidence of retinopathy of prematuri ty (ROP) in the area of Shanghai, and to provide the preliminary data for the ev aluation of present criteria for ROP screening. Methods Record s of 289 prematur e infants who had undergone ROP screening from the four NICU in Shanghai between February 2004 and January 2005 were analyzed. Screening criteria included prete rm infants or low birth weight (LBW) infants with BW of 2000g or less. The first examination starts at 4 to 6 weeks chronologic age or 32 weeks post conceptual age. Results In the 289 screened infants, 19 had developed acu te ROP. There we re 3 threshold ROP, 7 prethreshold ROP and 9 developed ROP less than prethreshol d. The incidence of ROP was 6.6%. According to the British recommended guideline s(BWle;1500 g or GAle;31 weeks), only 119 out of 289 needed screening and one ca se of stage 1 ROP was missed; the incidence of ROP was 15.1% (18/119). When lowered sc reening criteria to the American guidelines(BWle;1500g or GAle;28 weeks), t here were only 83 infants needed screening, and we missed 2 stage 1 and 1 prethreshold ROP and the incidence of ROP was 19.3% (16/83). Conclusions The i ncidence of ROP i s 6.6% according to our study. It is lower than other reports and it has somethi ng to do with our present screening guideline. Further epidemiological data are needed to modify the guideline accordingly.

      Release date:2016-09-02 05:46 Export PDF Favorites Scan
    • Application effect analysis of artificial intelligence automatic diagnosis system for diabetic retinopathy in elderly diabetic patients in community and hospital

      ObjectiveTo study the efficiency and difference of the artificial intelligence (AI) system based on fundus-reading in community and hospital scenarios in screening/diagnosing diabetic retinopathy (DR) among aged population, and further evaluate its application value. MethodsA combination of retrospective and prospective study. The clinical data of 1 608 elderly patients with diabetes were continuously treated in Henan Eye Hospital & Henan Eye Institute from July 2018 to March 2021, were collected. Among them, there were 659 males and 949 females; median age was 64 years old. From December 2018 to April 2019, 496 elderly diabetes patients were prospectively recruited in the community. Among them, there were 202 males and 294 female; median age was 62 years old. An ophthalmologist or a trained endocrinologist performed a non-mydriatic fundus color photographic examination in both eyes, and a 45° frontal radiograph was taken with the central fovea as the central posterior pole. The AI system was developed based on the deep learning YOLO source code, AI system based on the deep learning algorithm was applied in final diagnosis reporting by the "AI+manual-check" method. The diagnosis of DR were classified into 0-4 stage. The 2-4 stage patients were classified into referral DR group. ResultsA total of 1 989 cases (94.5%, 1 989/2 104) were read by AI, of which 437 (88.1%, 437/496) and 1 552 (96.5%, 1 552/1 608) from the community and hospital, respectively. The reading rate of AI films from community sources was lower than that from hospital sources, and the difference was statistically significant (χ2=51.612, P<0.001). The main reasons for poor image quality in the community were small pupil (47.1%, 24/51), cataract (19.6%, 10/51), and cataract combined with small pupil (21.6%, 11/51). The total negative rate of DR was 62.4% (1 241/1 989); among them, the community and hospital sources were 84.2% and 56.3%, respectively, and the AI diagnosis negative rate of community source was higher than that of hospital, and the difference was statistically significant (χ2=113.108, P<0.001). AI diagnosis required referral to DR 20.2% (401/1 989). Among them, community and hospital sources were 6.4% and 24.0%, respectively. The rate of referral for DR for AI diagnosis from community sources was lower than that of hospitals, and the difference was statistically significant (χ2=65.655, P<0.001). There was a statistically significant difference in the composition ratio of patients with different stages of DR diagnosed by AI from different sources (χ2=13.435, P=0.001). Among them, community-derived patients were mainly DR without referral (52.2%, 36/69); hospital-derived patients were mainly DR requiring referral (54.9%, 373/679), and the detection rate of treated DR was higher (14.3%). The first rank of the order of the fundus lesions number automatically identified by AI was drusen (68.4%) and intraretinal hemorrhage (48.5%) in the communities and hospitals respectively. Conclusions It is more suitable for early and negative DR screening for its high non-referral DR detection rate in the community. Whilst referral DR were mainly found in hospital scenario.

      Release date:2022-03-18 03:25 Export PDF Favorites Scan
    • Value of Mass Screening of Serum Pepsinogen Test for Asian Population with High-risk Gastric Carcinoma: A Meta-analysis

      ObjectiveTo systematically review the value of mass screening of serum pepsinogen test for Asian population with high-risk gastric carcinoma. MethodsWe electronically searched databases including PubMed, EMbase, The Cochrane Library (Issue 12, 2013), CNKI, WanFang Data, VIP and CBM for diagnostic tests on serum pepsinogen test versus with pathological biopsy/X-ray examination (gold standard) between January 2004 and January 2014. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data, and assessed methodological quality of included studies. Then meta-analysis was conducted using Meta-DiSc software (version 1.4). ResultsA total of 15 studies involving 180 934 subjects were included. ROC curve showed "shoulder-arm shape" distribution. The results of Spearman correlation analysis suggested a significance of the threshold effect (P=0.001). The results of meta-analysis showed that, the area under curve (AUC) was 0.74. ConclusionSerum pepsinogen has good value in the screening of gastric carcinoma among Asian permanent residents. Due to limited quality of studies, the above conclusion should be verified by conducting more high quality studies.

      Release date: Export PDF Favorites Scan
    • The value of abbreviated magnetic resonance imaging sequence in hepatocellular carcinoma screening: a meta-analysis

      ObjectiveTo systematically review the diagnostic efficacy of abbreviated magnetic resonance imaging sequence (AMRI) screening for hepatocellular carcinoma (HCC). MethodsPubMed, EMbase, The Cochrane Library, Web of Science, CNKI, WanFang Data and VIP databases were electronically searched to collect studies on the diagnostic efficacy of AMRI screening for HCC from inception to March 2022. Two reviewers independently screened the literature, extracted data and assessed the risk of bias of the included studies; then, meta-analysis was performed by using Stata 16.0 software. ResultsA total of 15 studies involving 2 823 participants were included. The results of meta-analysis showed that combined sensitivity and specificity of AMRI for HCC were 0.85 (95%CI 0.83 to 0.87) and 0.93 (95%CI 0.90 to 0.94). Subgroup analysis showed that, the combined sensitivity and specificity of NC AMRI and HBP AMRI were 0.84 (95%CI 0.81 to 0.87), 0.92 (95%CI 0.88 to 0.95) and 0.88 (95%CI 0.84 to 0.91), 0.93 (95%CI 0.91 to 0.94), respectively. The combined sensitivity and specificity of T2+DWI+HBP in HBP AMRI had the highest diagnostic efficacy. ConclusionCurrent evidence shows that all AMRI protocols have acceptable sensitivity and specificity for HCC screening. Among them, T2+DWI+HBP protocol shows the highest diagnostic efficiency. Due to the limited quality and quantity of the included studies, more high-quality studies are needed to verify the above conclusion.

      Release date:2022-07-14 01:12 Export PDF Favorites Scan
    • A review of guidelines for diabetic retinopathy screening

      Diabetic retinopathy (DR) is the most common cause of preventable blindness in the working-age population. In addition to optimizing the hyperglycemia, hypertension, hyperlipidemia and other risk factors, regular fundus examination is essential for early diagnosis asymptomatic DR and timely treat the sight-threatening DR, so as to reduce blindness and severe visual impairment caused by DR. Clinical practice guidelines for the screening and management of DR have been implemented throughout the world, but there are reasonable differences between existing guidelines in the recommended timing of first retinal examination, screening intervals, methods for examination and criteria for referral to an ophthalmologist. It is of great clinical significance to have a detailed understanding of the current guidelines for DR screening and their clinical basis.

      Release date:2019-03-18 02:49 Export PDF Favorites Scan
    • Discussion on Screening for Prostate Cancer

      Prostate cancer is a common disease in the USA and Europe, with a gradually increasing incidence in China, and presents a significant health burden for older men. The lack of modifiable risk factors has made early detection as a strategy to reduce mortality. Current methods of screening involve the measurement of serum prostate-specific antigen (PSA) and digital rectal examination followed by biopsy. With PSA screening evidence of level I absent, the evidence on the use of PSA as a screening test is still highly controversial. Furthermore, there is controversy over whether screen-detected lesions will become clinically significant. There are three major treatment options for localized disease: radical prostatectomy, radical radiotherapy and monitoring with treatment if required. There is no evidence of randomized controlled trial (RCT) to suggest a survival advantage of any of these treatments. Opinions about the related benefits and risks of screening vary widely. In the absence of RCT of benefit for screening, many now suggest “informed consensus” screening, which encourages a discussion between the patient and his physician with both sides informed of all of the issues.

      Release date:2016-09-07 02:27 Export PDF Favorites Scan
    • The Effectiveness of Peak Flow Meter in COPD Screening

      ObjectiveTo analyze the sensitivity of peak flow meter screening in different subgroups of chronic obstructive pulmonary disease (COPD). MethodsA total of 156 outpatients with COPD from Peking Union Medical Hospital from May 2013 to December 2014 were recruited in the study. Each patient's symptoms,history of exposure to risk factors,and the times of exacerbation in last year was recorded. All patients completed CAT,mMRC,the St George's Respiratory Questionnaire (SGRQ),6 minutes walking test,spirometry,and peak expiratory flow (PEF) by peak flow meter. ResultsUsing the cut-off of PEF%pred=80%,the PEF detected 120 COPD patients in 156 subjects. The predictive factors of abnormal PEF%pred in COPD was FEV1%pred and the total score of SGRQ (P<0.05). PEF screening could identify 76.9% of COPD patients,30.0%-60.0% of patients of less symptoms (mMRC<2 or CAT<10 or SGRQ<25),83.3%-90.9% of COPD patients with more symptoms (mMRC ≥ 2 or CAT ≥ 10 or SGRQ ≥ 25),27.7% of COPD patients with mild airflow limitation,68.5% of COPD patients with moderate airflow limitation,83.3% of COPD patients with moderate to very severe airflow limitation. When grouped by GOLD combined assessment method,PEF screening could identify 35.2% of patients of group A,75.0% of patients of group B,and 95.9% of patients of group C and D. The cut-off value of PEF% pred=80% showed low sensitivity to early stage of COPD,but when using the cut-off value of PEF% pred=95%,that sensitivity increased signifcantly. ConclusionsPeak flow meter may be used as a tool to screen COPD. It can identify part of COPD patients especially for those patients with more symptoms,requiring regular treatment,with deteriorated pulmonary function and high risk of exacerbation.

      Release date:2016-10-02 04:55 Export PDF Favorites Scan
    • Screening, domestication and identification of intestinal uric acid degrading bacteria in low uric acid population

      As the largest ecosystem of human body, intestinal microorganisms participate in the synthesis and metabolism of uric acid. Developing and utilizing intestinal bacteria to degrade uric acid might provide new ideas for the treatment of hyperuricemia. The fecal samples of people with low uric acid were inoculated into uric acid selective medium with the concentration of 1.5 mmol/L for preliminary screening, and the initially screened strains that may have degradation ability were domesticated by concentration gradient method, and the strains with high uric acid degradation rate were identified by 16S rRNA sequencing method. A strain of high-efficiency uric acid degrading bacteria was screened and domesticated from the feces of people with low uric acid. The degradation rate of uric acid could reach 50.2%. It was identified as Escherichia coli. The isolation and domestication of high efficient uric acid degrading strains can not only provide scientific basis for the study of the mechanism of intestinal microbial degradation of uric acid, but also reserve biological strains for the treatment of hyperuricemia and gout in the future.

      Release date:2022-10-25 01:09 Export PDF Favorites Scan
    • The accuracy of screening technologies for liver cancer: a meta-analysis

      ObjectivesTo evaluate the accuracy of liver cancer screening techniques to inform screening intervention and early diagnosis.MethodsWe searched PubMed, The Cochrane Library, EMbase, Web of Science, CNKI, WanFang Data, CBM, VIP databases to collect relevant diagnostic accuracy studies of screening technologies for liver cancer from January 1980 to December 2017. Two reviewers independently screened the literature, extracted the data and assessed the risk of bias of included studies. Then meta-analysis was performed by using Meta-Disc 1.4 software.ResultsA total of 54 publications with 47 728 individuals were included. In terms of pooled sensitivity from the meta-analysis, it was estimated as 0.71 (95%CI 0.70 to 0.72), 0.57 (95%CI 0.56 to 0.59) and 0.43 (95%CI 0.41 to 0.45); the pooled specificity was estimated as 0.92 (95%CI 0.92 to 0.93), 0.95 (95%CI 0.94 to 0.96) and 0.95 (95%CI 0.94 to 0.96); the pooled positive likelihood ratio was 5.65 (95%CI 4.37 to 7.30), 13.24(95%CI 4.25 to 41.22) and 11.39 (95%CI 4.01 to 32.35); the pooled negative likelihood ratio was 0.35 (95%CI 0.31 to 0.39), 0.38 (95%CI 0.29 to 0.52) and 0.49 (95%CI 0.39 to 0.62); the diagnosis odds ratio was 17.23 (95%CI 12.26 to 24.20), 33.79 (95%CI 12.65 to 90.24) and 24.41(95%CI 9.23 to 64.53) for AFP alone with cut-off of 20, 200 and 400 ng/mL, respectively. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnosis odds ratio were 0.65 (95%CI 0.62 to 0.69), 0.97 (95%CI 0.97 to 0.97), 16.48 (95%CI 9.55 to 28.42), 0.27 (95%CI 0.18 to 0.42) and 64.54 (95%CI 30.16 to 138.11) for ultrasound examination alone. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnosis odds ratio were 0.96 (95%CI 0.94 to 0.98), 0.96 (95%CI 0.96 to 0.96), 10.76 (95%CI 2.62 to 44.27), 0.07 (95%CI 0.02 to 0.22) and 160.59 (95%CI 31.61 to 816.03) for the combined strategy.ConclusionFor liver cancer screening technologies, the overall accuracy of serum AFP test alone is the optimum at cut-off of 20 ng/mL, and the sensitivity increased substantially when combined with ultrasound examination.

      Release date:2018-06-04 08:52 Export PDF Favorites Scan