Objective To explore the application value of shear wave elastography (SWE) combined with diaphragmatic thickening fraction (DTF) and rapid shallow breathing index (RSBI) in predicting the results of weaning of patients with mechanical ventilation. Methods Fifty-two patients with severe illness who were hospitalized in this hospital from January 2022 to September 2022 were treated with mechanical ventilation. After meeting the conditions for weaning, they underwent spontaneous breathing test, and the diaphragm function of patients was evaluated by measuring DTF using ultrasound technology and shear modulus (SM) using SWE technology. According to the weaning results, they were divided into weaning success group and weaning failure group, The differences of mechanical ventilation time, acute physiology and chronic health evaluation Ⅱ (APACHE Ⅱ) score, respiratory rate, RSBI, oxygenation index, DTF, SM and other parameters between the two groups were compared. Multivariate logistic regression was used to analyze the factors affecting the withdrawal results. The receiver operator characteristic (ROC) curve was used to evaluate the predictive value of potential influencing factors on the withdrawal results. Results There were 39 cases of successful withdrawal and 13 cases of failure. There were significant differences in mechanical ventilation time, respiratory rate, RSBI, DTF and SM between the successful weaning group and the failure group (P<0.05). Through multivariate logistic regression analysis, RSBI [area under the ROC curve (AUC)=0.771, 95% confidence interval (CI) 0.589 - 0.953], DTF (AUC=0.806, 95%CI 0.661 - 0.951), SM (AUC=0.838, 95%CI 0.695 - 0.981) were independent factors that affected the results of withdrawal. The single parameter AUC was smaller than the combined index with RSBI≤70.48 times·min–1L–1, DTF≥30.0%, SM≥10.0 kPa as the cutoff value (AUC=0.937, 95%CI 0.714 - 1.0, diagnostic sensitivity, specificity and accuracy were 94.9%, 84.6% and 92.3% respectively). Conclusions SWE technology provides a new quantitative index for evaluating diaphragm function by evaluating diaphragm stiffness. Diaphragm stiffness combined with DTF and RSBI can better predict the successful withdrawal in patients with mechanical ventilation.
Quantitative measurement of strain distribution of arterial vessel walls due to pulsatile blood flow within the vascular lumen is valuable for evaluating the elasticity of arterial wall and predicting the evolution of plaques. The present paper shows that the three-dimensional (3D) strain distribution are estimated through uni-directional coupling for 3D vessel and blood models reconstructed from intravascular ultrasound (IVUS) images with the computational fluid dynamics (CFD) numerical simulation technique. The morphology of vessel wall and plaques as well as strain distribution can be visually displayed with pseudo-color coding.
In order to meet the requirements of ultrasound bone density measurement, we designed a software based on Visual Studio C++ 2008. The software includes interface design, acquisition and control, data processing and parameter extraction, data storage and printing. Excellent human-computer interface (HCI) will give users a convenient experience. Auto gain control (AGC) and digital filter can improve the precision effectively. In addition, we can observe waveform clearly in real time. By using USB communication, we can send control commands to the acquisition and get data effectively, which can shorten the measuring time. Then we calculated the speed of sound (SOS) and broadband ultrasound attenuation (BUA). Patients' information can be accessed by using XML document. Finally, the software offers printing function.
ObjectivesTo evaluate the predicting value of bedside pulmonary ultrasound in bronchopulmonary dysplasia (BPD) in premature infants.MethodsPremature infants with gestational age below 28 weeks or birth weight below 1 500 g admitted to NICU of Chengdu Women and Children’s Central Hospital from June 2018 to June 2019 were included. Pulmonary bedside ultrasound monitoring was performed on the 3rd, 7th, 14th and 28th day after admission, and the characteristic ultrasound images were recorded and scored. BPD were diagnosed by NICHD standard. The clinical data and pulmonary ultrasound data were compared and analyzed. Then diagnostic value of bedside pulmonary ultrasound in BPD of premature infants were analyzed.ResultsA total of 81 children involving 32 BPD and 49 non-BPD were included. The sensitivity (Sen), specificity (Spe) and area under curve (AUC) of receiver operating characteristic (ROC) of the "alveolar-interstitial syndrome" within 3 days after birth and the "fragment sign" on 28 days after birth were 81.25%, 51.02%, 0.66 and 31.25%, 97.96%, 0.65, respectively. The lung ultrasound scores in the BPD group on the 3rd, 7th, 14th, and 28th day after birth were 71.99.%, 68.39%, 0.71; 87.50%, 57.14%, 0.72; 78.13%, 73.47%, 0.76 and 56.25 %, 75.51%, 0.66. Sen, Spe and ROC AUC of comprehensive evaluation of lung ultrasound predicted the occurrence of BPD been 81.25%, 63.27%, and 0.85.ConclusionsThe comprehensive evaluation of combination of "alveolar interstitial syndrome" image characteristics within 3 days after birth, "fragment sign" image characteristics after 28 days, and lung ultrasound score at different times after birth can predict the premature infants with bronchopulmonary dysplasia.
Objective To summarize experience and efficacy of multidisciplinary treatment for severe intra-abdominal infection. Methods The clinical data of 17 patients with severe intra-abdominal infection underwent multidisciplinary treatment were analyzed retrospectively. There were 5 cases of severe acute pancreatitis, 4 cases of postoperative biliary fistula, 2 cases of intestinal fistula, 2 cases of pancreatic trauma, 1 case after resection for intestinal necrosis, 1 case of abdominal trauma, 1 case after operation for liver abscess, 1 case of unexplained severe intra-abdominal infection. The experiences of multidisciplinary treatment including the intensive care unit (ICU), surgery, blood purification center, and departments of pharmacy, nutrition, and digestion and internal medicine, and so on were summarized. Results After multidisciplinary treatment, 13 patients were cured, of which 4 patients treated by non-open operation. Three patients died, including 1 patient died of infectious shock, 1 patient died of pancreatic bed bleeding, 1 patient died of multiple organ failure. There was 1 case of automatic discharge. Conclusions Multidisciplinary treatment including ICU, surgery, blood purification center, and departments of pharmacy, nutrition, and digestion and internal medicine, and so on has an exact clinical curative effect in patients with severe intra-abdominal infection. Concept of damage control should be followed by surgical intervention. Abdominal cavity puncture and drainage has some advantages of small trauma and good clinical effect, which is suitable for infection control of patients with severe intra-abdominal infection, it could provide surgical condition and opportunity for patients required further surgical treatment.
ObjectiveTo explore the value of portable ultrasound in assessing peripheral vein thrombosis of the injured in Lushan earthquake on April 20, 2013. MethodsFrom April 20th to May 5th in 2013, 321 earthquake victims were admitted into our hospital, and 203 fractured patients of them accepted peripheral venous two-dimensional and color doppler ultrasound examination beside the bed every three days. ResultsSixty-three patients (82 locations) suffered from venous thrombosis in the 203 earthquake victims, and the rate was 31.03% (63/203). Among them, one suffered from iliac vein thrombosis; 53 patients (71 limbs) were attacked by lower limb venous thrombosis; 9 patients (10 limbs) suffered from upper limb venous thrombosis. The time was from 2 to 15 days after trauma when the victims were diagnosed to have thrombus at the first time, averaging (6.1±3.8) days. On admission day, 45 victims were diagnosed with peripheral vein thrombosis. Among them, 19 patients increased the scope of thrombus after admission in hospital, while 26 victims reduced the scope. Eighteen victims suffered from newly developed peripheral venous thrombus after admission in hospital. None of the hospitalized patients died of pulmonary embolism. ConclusionsThe victims injured in the earthquake have a high incidence of peripheral vein thrombosis, and the calf is the main site of the disease. After trauma, peripheral venous thrombosis occurs within a short time. Bedside portable ultrasound is the first choice for peripheral vein thrombosis in the earthquake victims.
Objective To explore the value of three-dimensional contrast-enhanced ultrasound angiography in the differential diagnosis of breast masses. Methods A total of 120 patients with breast masses who were treated in our hospital from July 2013 to February 2016 were selected as the research objects retrospectively, including 70 patients of benign tumor (benign group) and 50 patients of malignant tumor (malignant group) that confirmed by surgery and pathology. All patients were given conventional two-dimensional ultrasound and three-dimensional contrast-enhanced ultrasound angiography during the diagnosis. Compared the imaging features of benign group and malignant group, and compared the diagnostic value of two-dimensional ultrasound and three-dimensional contrast-enhanced ultrasound angiography for breast masses. Results Compared with benign group, the rates of irregular masses, unclear boundary, inhomogeneous echo, lateral shadowing, echo attenuation, and micro calcification in the malignant group were all higher (P<0.05). The three-dimensional contrast-enhanced ultrasound angiography scores in malignant group and benign group were significantly different with each other (P<0.05), the score of the malignant group was higher than that of benign group. The 2- and 3-score was common in benign group, but 4- and 5-score was common in malignant group. The diagnostic sensitivity of two-dimensional ultrasound and three-dimensional contrast-enhanced ultrasound angiography for breast masses were 97.1% (68/70) and 98.6% (69/70) respectively, and the specificity were 80.0% (40/50) and 96.0% (48/50) respectively, the specificity of three-dimensional contrast-enhanced ultrasound angiography was significantly higher than that of two-dimensional ultrasound (P<0.05). Conclusion Two-dimensional ultrasound and three-dimensional contrast-enhanced ultrasound angiography both have a certain diagnostic value in the differential diagnosis of breast masses, but the three dimensional contrast-enhanced ultrasound angiography can get more information through assessment of richness of the microvascular in tumor tissue, so as to improve the diagnostic specificity and is worthy of popularization and application.
ObjectiveTo investigate the clinical value of cervical vascular color Doppler ultrasound for dignosis of nonrecurrent laryngeal nerve before thyroid surgery. MethodsThere were 1931 cases of thyroid patients treated between January 2010 to Jule 2014, group these patients according to the results of preoperative chest radiograph examination, the chest radiograph shows abnormal vessels image were group A (45 cases), no abnormalities were group B (1886 cases). Before operaton, made patients of group A to have routine carotid duplex ultrasound to identify whether the right subclavian artery abnormalities. All patients were exposed to conventional methods of recurrent laryngeal nerve during surgery. ResultsThe 45 patients of group A, chest angiography showed 17 cases with right subclavian artery abnormalities, they were confirmed that all the 17 patients were nonrecurrent laryngeal nerve by surgery, no damage cases. The other 28 cases showed a normal right subclavian artery and no cases of nonrecurrent laryngeal nerve. The 1886 patients in group B, surgical exploration found four cases with nonrecurrent laryngeal nerve, injury in 1 case. The 21 patients whose nonrecurrent laryngeal nerve were on the right side, there were no left side with nonrecurrent laryngeal nerve and no co-exist cases of nonrecurrent and recurrent laryngeal nerve. The average exposure time of nonrecurrent laryngeal nerve in patients of group A (17 cases) was significantly shorter than that group B[(4.28±1.08) min vs. (15.50±2.08) min, t=-15.978, P=0.000]. ConclusionsThe cervical vascular color Doppler ultrasound examination before thyroid surgery can be adjuvant used, if there is the right subclavian artery abnormalities, it showes that there is the right side nonrecurrent laryngeal nerve. So as to effectively prevent the damage of nonrecurrent laryngeal nerve during thyroid surgery.
Objective To explore the clinical value of shear wave elastography in the evaluation of quadriceps femoris lesions in patients with chronic obstructive pulmonary disease (COPD). Methods Fifty-eight COPD patients who were admitted to Chengdu First People’s Hospital and 55 healthy controls were included in the study between August 2021 and February 2022. The thickness, circumference, cross-sectional area and Young's modulus of quadriceps femoris in all subjects were measured using shear wave elastography combined with conventional two-dimensional ultrasound. The differences in ultrasound parameters between the two groups were compared, and the correlation between each ultrasound parameter and clinical evaluation indicators (modified British Medical Research Council Scale, COPD Assessment Test, six-minute walk test, and five-time sit-to-stand test) was analyzed. Results Young’s modulus values of the quadriceps femoris muscle were smaller in the COPD group than those in the healthy control group [COPD Group: rectus femoris 6.72 (6.22, 7.36) kPa, vastus medialis 6.25 (5.82, 6.79) kPa, vastus lateralis 6.94 (6.17, 7.48) kPa; healthy control group: rectus femoris 11.40 (10.23, 12.11) kPa, vastus medialis 10.77 (9.62, 11.42) kPa, vastus lateralis 11.14 (10.42, 12.52) kPa]. The differences were statistically significant (all P<0.05). The Young's modulus value of the rectus femoris muscle correlates with the aforementioned clinical evaluation indicators, with positive correlation with six-minute walk distance and negative correlation with COPD Assessment Test, modified British Medical Research Council Scale, five-time sit-to-stand time (P<0.05). Quadriceps thickness, circumference, and cross-sectional area measured by conventional two-dimensional ultrasound were not significantly different between the two groups, nor were there significant correlations between each parameter and clinical parameters (P>0.05). In addition, shear wave elastography has good reproducibility in the measurement of Young's modulus in quadriceps. Conclusions Shear wave elastography can identify quadriceps lesions earlier than conventional two-dimensional ultrasound in COPD patients, and there is a significant correlation between its measurements and the clinical condition of COPD patients. Shear wave elastography may provide a simple and noninvasive method for clinical evaluation of quadriceps femoris lesions in COPD patients.
ObjectiveTo systematically review the value of ultrasound contrast agents injected subcutaneously for diagnosing sentinel lymph nodes of breast cancer. MethodsWe electronically searched databases including PubMed, EMbase, The Cochrane Library, CNKI, CBM, WanFang Data, and Medalink from their inception to July 2014, to collect diagnostic accuracy studies of ultrasound contrast agents injected subcutaneously for diagnosing sentinel lymph nodes of breast cancer. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed by using Meta-Disc 1.4 software. ResultsEight studies involving 311 sentinel lymph nodes were included. The results of meta-analysis showed that, the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and the area under curve (AUC) of SROC were 0.89 (95%CI 0.84 to 0.93), 0.81 (95%CI 0.72 to 0.87), 4.14 (95%CI 2.20 to 7.79), 0.15 (95%CI 0.10 to 0.25), 33.23 (95%CI 11.17 to 98.83), and 0.96 respectively. ConclusionContrast-enhanced ultrasound has a high value in diagnosis of sentinel lymph nodes of breast cancer. Due to limited quality and quantity of the included studies, more high quality and large-scale studies are needed to verify the above conclusion.