Biological valves can lead to structural valve degeneration (SVD) over time and due to various factors, reducing their durability. SVD patients need to undergo valve replacement surgery again, while traditional open chest surgery can cause significant trauma and patients often give up treatment due to intolerance. Research has shown that as an alternative treatment option for reoperation of thoracic valve replacement surgery, redo-transcatheter aortic valve replacement for SVD is safe and effective, but still faces many challenges, including prosthesis-patient mismatch, high cross valve pressure difference, and coronary obstruction. This article aims to review the strategies, clinical research status and progress of redo-transcatheter aortic valve replacement in SVD patients.
Transcatheter aortic valve replacement (TAVR) has become one of the main treatments for severe aortic stenosis. However, percutaneous coronary intervention (PCI) is often required in elderly patients who combine with coronary artery disease. This paper reports a case of one-stop TAVR+PCI operation for a 71-year-old male patient with left main bifurcation lesions and severe aortic stenosis. During the procedure, first of all, the coronary arteries were assessed by angiography, and the pigtail catheter was implanted in the left ventricle after the straight guidewire transvalved successfully; then PCI was performed on the diseased coronary arteries; finally, the stenosis of aortic valve was treated with TAVR. After operation, the hemodynamics of the patient was stable and symptoms were significantly improved, showing a good clinical effect of one-stop operation of TAVR+PCI.
ObjectiveTo assess outcomes of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation.MethodsA total of 129 patients underwent transfemoral TAVR in Fuwai Hospital from May 2019 to October 2020 were retrospectively analyzed. There were 83 males and 46 females with an average age of 72.26±8.97 years. The patients were divided into a pure native aortic valve regurgitation group (17 patients) and an aortic valve stenosis group (112 patients).ResultsThe incidence of valve in valve was higher in the pure native aortic valve regurgitation group (47.0% vs. 16.1%, P<0.01). There was no statistical difference between the two groups in conversion to surgery, intraoperative use of extracorporeal circulation, intraoperative left ventricular rupture, postoperative use of extracorporeal membrane oxygenation (ECMO), peripheral vascular complications, disabled stroke, death, or pacemaker implantation. There was no statistical difference in the diameter of annulus (25.75±2.21 mm vs. 24.70±2.90 mm, P=0.068) or diameter of outflow tract (25.82±3.75 mm vs. 25.37±3.92 mm, P=0.514) between the pure native aortic valve regurgitation group and the aortic valve stenosis group.ConclusionTransfemoral TAVR is a feasible method for patients with pure native aortic valve regurgitation. The diameter of annulus plane, the diameter of outflow tract and the shape of outflow tract should be evaluated.
In recent years, the number of interventions for valvular heart disease has been increasing day by day, and it has become a hot topic in the field of cardiovascular surgery. Given the aging global population and trends in the prevalence of valvular disease and the broadening of indications for transcatheter aortic valve replacement (TAVR), a breakthrough of 130000 TAVR procedures is expected by 2026. In the new technology development period, the development potential and technical advantages of heart valve interventional therapy should be faced squarely. This paper focuses on key issues such as comparison of outcomes after TAVR versus surgical aortic valve replacement (SAVR), prosthetic valve endocarditis after TAVR, and broadening of indications for TAVR, as well as recommendations on how surgeons face the era of TAVR. We hope that this article will help and attract the attention of cardiac surgeons.
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up period. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
Transcatheter aortic valve replacement and endovascular abdominal aortic repair have now become the first-line treatment options for aortic stenosis and abdominal aortic disease, respectively. For patients with both diseases, combined procedures have been reported in a few domestic and foreign publications. However, all the procedures were performed under general anesthesia. Here, we reported a case of simultaneous minimalist transfemoral transcatheter aortic valve replacement and endovascular repair of the abdominal aorta for a 78-year-old male patient with aortic stenosis and abdominal aortic ulcer, and the surgical results were satisfactory.
ObjectiveTo compare and analyze the clinical effects of two kinds of frame design valves after transcatheter aortic valve replacement (TAVR).MethodsWe retrospectively reviewed 124 patients who underwent TAVR and were followed up for 1 year. There were 71 males and 53 females aged 75.57±6.21 years. These patients were treated with Venus-A or Edwards Sapien aortic valves. The hemodynamics and cardiac function of these two kinds of transcatheter aortic valves (THV) were evaluated by echocardiography. The 30-day mortality and 1-year clinical effect of the patients were calculated.ResultsEight-one patients used Venus-A valve and 43 patients used Edwards Sapien valve. The aortic valve transaortic pressure gradient was reduced and the rate of perivalvular leakage was low (both 2.6%) in both groups, and there was no statistical difference between the two groups. The implantation rate of permanent pacemaker was 17.3% and 11.6%, respectively. The 1-month survival (94.0% and 93.0%) and 1-year survival (94.0% and 91.0%) rates were not statistically different.ConclusionThe two groups of THV with different stent structures have good short-term clinical effect and low implantation rate of permanent pacemaker.
Transcatheter aortic valve replacement (TAVR) for aortic stenosis has been confirmed to be safe and efficient, and its status has gradually increased with the continuous updating of guidelines. But for severe pure aortic valve regurgitation, it has long been considered a relative contraindication to TAVR. However, many elderly, high-risk patients with pure aortic regurgitation have also been treated with TAVR and prognosis was improved through off-label use of transcatheter heart valves due to contraindications to surgery or intolerance. But because of the complexity and challenging anatomic features, high technical requirements, limited device success rate, high rate of complications, and lack of randomized controlled studies to confirm its safety and efficacy, TAVR treatment of pure aortic regurgitation has been evolving in a debate. In recent years, with the application of new-generation valves and an increasing number of studies, some new insights have been gained regarding TAVR for severe aortic regurgitation, and this article will review the progress of research on TAVR for severe pure aortic regurgitation.
ObjectiveTo summarize the experience and efficacy of "one-stop" left atrial appendage clipping (LAAC) combined with transcatheter aortic valve replacement (TAVR) for patients with atrial fibrillation (AF) and aortic valve disease. Methods From April 2018 to March 2021, 16 patients with AF and severe aortic valve disease underwent "one-stop" LAAC and TAVR in our department. All patients had long-standing persistent AF. There were 10 males and 6 females with an average age of 77.2±6.2 years. CHA2DS2-VASc score was 4.4±0.8 points, and HAS-BLED score was 3.5±0.7 points. ResultsAll patients successfully underwent "one-stop" LAAC combined with TAVR. There was no death during perioperative and follow-up periods. The length of the left atrial appendage base measured during the operation was 37.8±3.5 mm. The types of atrial appendage clip were 35 mm (n=3), 40 mm (n=8) and 45 mm (n=5). The time required for clipping the left atrial appendage (from skin cutting to skin suturing) was 25.7±3.8 min. There was no stroke or bleeding of important organs during the perioperative period. The average hospital stay was 6.8±2.0 d. The follow-up time was 19.6±10.1 months, during which there was no patient of cerebral hemorrhage or cerebral infarction. During the administration of warfarin, 2 patients had subcutaneous ecchymosis and 1 patient had gingival bleeding. Conclusion"One-stop" LAAC combined with TAVR can be safely and effectively used to treat AF and aortic valve disease patients with high risk of thromboembolism and anticoagulant bleeding. The early and middle-term curative effect is satisfactory.
Transcatheter aortic valve replacement (TAVR) has become a common theraputic option for aortic stenosis, but the evidence for precise anatomy for TAVR is accumulating. This paper presents the case of an 71-year-old female patient who had an extremely high risk of coronary obstruction due to both coronary ostia lying too low. The patient underwent TAVR with the help of coronary protection successfully. During the procedure, the patient was protected with wires only for both coronaries. After deployment, angiofluoroscopy suggested that chimney stenting should be applied for left coronary. The whole procedure was unenventful and both coronaries were seen.