• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "transcatheter aortic valve replacement" 37 results
    • Transapical transcatheter aortic valve replacement in bicuspid aortic valve patients: In-hospital outcomes

      ObjectiveTo compare the in-hospital outcomes of transapical transcatheter aortic valve replacement (TA-TAVR) for bicuspid aortic valve (BAV) patients and tricuspid aortic valve (TAV) patients. MethodsPatients (including BAV and TAV patients) who underwent TA-TAVR with the J-ValveTM in West China Hospital from July 2014 to July 2020 were included consecutively. The clinical outcomes of the patients were analyzed. ResultsA total of 354 patients were included in the study, 75 in the BAV group and 279 in the TAV group. There were 229 males and 125 females with a mean age of 72.2±6.0 years. No death occurred during the procedure, and the overall technical success rate was 97.7%. The all-cause in-hospital mortality rate was 1.4%. Twenty (26.7%) patients with BAV and 46 (16.5%) patients with TAV had mild or higher perivalvular leaks immediately after the procedure. No patients with BAV required permanent pacemaker implantation postoperatively, while 13 (4.7%) TAV patients required permanent pacemaker implantation, with an overall pacemaker implantation rate of 3.7%. One (1.3%) BAV patient and 7 (2.5%) TAV patients developed acute kidney injury postoperatively. One (1.3%) BAV patient and 1 (0.4%) TAV patient developed perioperative myocardial infarction. The average postoperative hospital stay was 7.6±3.6 d for BAV patients and 8.6±6.1 d for TAV patients. There was no statistical difference in primary or secondary in-hospital outcomes between BAV and TAV patients (P>0.05). ConclusionCompared to TAV patients, BAV patients have similar in-hospital outcomes, with a low incidence of adverse clinical outcomes, which provides preliminary evidence for its implementation in Chinese patients with a high proportion of BAV.

      Release date:2023-07-25 03:57 Export PDF Favorites Scan
    • Clinical research status and progress of redo-transcatheter aortic valve replacement for structural biovalvular degeneration

      Biological valves can lead to structural valve degeneration (SVD) over time and due to various factors, reducing their durability. SVD patients need to undergo valve replacement surgery again, while traditional open chest surgery can cause significant trauma and patients often give up treatment due to intolerance. Research has shown that as an alternative treatment option for reoperation of thoracic valve replacement surgery, redo-transcatheter aortic valve replacement for SVD is safe and effective, but still faces many challenges, including prosthesis-patient mismatch, high cross valve pressure difference, and coronary obstruction. This article aims to review the strategies, clinical research status and progress of redo-transcatheter aortic valve replacement in SVD patients.

      Release date:2024-02-29 12:02 Export PDF Favorites Scan
    • Interpretation of 2022 version of Chinese expert consensus on antithrombotic therapy after transcatheter aortic valve implantation

      Transcatheter aortic valve replacement (TAVR) is effective in the treatment of severe symptomatic aortic stenosis and its applicable population is also gradually expanding, but it carries risk of ischemic and bleeding events, which underscores the importance of optimizing adjuvant antithrombotic regimens. The release of the 2022 version of Chinese expert consensus on antithrombotic therapy after transcatheter aortic valve implantation has promoted the standardized and safe development of antithrombotic therapy after TAVR in China. Combined with the latest progress of antithrombotic therapy after TAVR, from emphasizing ischemia and bleeding risk assessment, single-agent antiplatelet therapy for patients without anticoagulation indications, the selection of antithrombotic strategies for patients with other antithrombotic indications, antithrombotic strategy changes in postoperative valve thrombosis and bleeding events, this article interprets this consensus.

      Release date:2022-05-24 03:47 Export PDF Favorites Scan
    • Effect of pulmonary hypertension on the prognosis of patients with severe aortic stenosis after transcatheter aortic valve replacement: A systematic review and meta-analysis

      Objective To systematically evaluate the impact of pulmonary hypertension (PH) on the prognosis of patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). Methods A computerized search was conducted in CNKI, Wanfang Data, VIP, CBM, PubMed, The Cochrane Library, EMbase, and Web of Science databases from inception to June 2023 for cohort studies on the prognostic impact of PH in severe AS patients undergoing TAVR. Two researchers independently screened the literature, extracted data, and assessed the quality of included studies. Stata 17.0 software was used for meta-analysis. Results A total of 16 cohort studies were included, all with Newcastle-Ottawa Scale scores≥7. Meta-analysis results showed that, compared with AS patients without PH, those with PH had significantly higher 1-year all-cause mortality after TAVR [OR=2.10, 95%CI (1.60, 2.75), P<0.01], 30-day all-cause mortality [OR=2.09, 95%CI (1.54, 2.83), P<0.01], and cardiovascular mortality [OR=1.49, 95%CI (1.18, 1.90), P<0.01]. The differences between the two groups in major bleeding events, stroke, myocardial infarction, pacemaker implantation, and postoperative renal failure were not statistically significant. For outcome indicators with significant heterogeneity, subgroup analyses were performed based on PH measurement methods, diagnostic criteria, and different types of PH. The results showed that most subgroup combined results were consistent with the overall findings and that heterogeneity was significantly reduced. Conclusion PH significantly increases the 30-day all-cause mortality, 1-year all-cause mortality, and cardiovascular mortality in patients with severe AS undergoing TAVR.

      Release date:2025-07-23 03:13 Export PDF Favorites Scan
    • A case of transcatheter aortic valve replacement with right-&-left coronary protection

      Transcatheter aortic valve replacement (TAVR) has become a common theraputic option for aortic stenosis, but the evidence for precise anatomy for TAVR is accumulating. This paper presents the case of an 71-year-old female patient who had an extremely high risk of coronary obstruction due to both coronary ostia lying too low. The patient underwent TAVR with the help of coronary protection successfully. During the procedure, the patient was protected with wires only for both coronaries. After deployment, angiofluoroscopy suggested that chimney stenting should be applied for left coronary. The whole procedure was unenventful and both coronaries were seen.

      Release date:2022-05-24 03:47 Export PDF Favorites Scan
    • Simultaneous minimalist transfemoral transcatheter aortic valve replacement and endovascular abdominal aortic repair: A case report

      Transcatheter aortic valve replacement and endovascular abdominal aortic repair have now become the first-line treatment options for aortic stenosis and abdominal aortic disease, respectively. For patients with both diseases, combined procedures have been reported in a few domestic and foreign publications. However, all the procedures were performed under general anesthesia. Here, we reported a case of simultaneous minimalist transfemoral transcatheter aortic valve replacement and endovascular repair of the abdominal aorta for a 78-year-old male patient with aortic stenosis and abdominal aortic ulcer, and the surgical results were satisfactory.

      Release date:2025-08-29 01:05 Export PDF Favorites Scan
    • A one-stop operation of transcarotid transcatheter aortic valve replacement and patent ductus arteriosus: a case report

      This case was a 58-year-old female patient with patent ductus arteriosus (PDA) and severe aortic stenosis. Upon admission, she had severe heart failure and severe edema of both lower extremities unable to lie flat. After cardiac function adjustment and under general anesthesia, she underwent a one-stop operation of PDA occlusion and transcarotid transcatheter aortic valve replacement due to the severe aortic arch stenosis which brought high risk in transfemoral artery approach. Her symptoms improved significantly, and she was discharged only 6 days after operation. At the follow-up 3 months after operation, the aortic valve transvalvular pressure gradient improved significantly, the ductus arteriosus murmur disappeared, and the patient recovered well.

      Release date:2022-05-24 03:47 Export PDF Favorites Scan
    • Lifelong management of patients with aortic regurgitation

      Aortic regurgitation (AR) is a common heart valve disease, and aortic valve replacement is an important treatment at present. With the advent of new methods such as transcatheter aortic valve replacement, patients with high-risk AR have been effectively treated. In particular, the emergence of new generations of transcatheter prosthetic valve systems has made the treatment of patients with AR more and more abundant. To treat patients with AR, it is necessary to establish the concept of “once diagnosed, lifelong management”, delay the progression of the disease through various means, and ultimately reduce the mortality of patients with AR and improve the quality of life. Therefore, this article reviews the basic characteristics of AR patients in China, the development and challenges faced by transcatheter aortic valve replacement surgery, follow-up, and postoperative rehabilitation plans, aiming to help physicians use different methods in a reasonable and standardized manner when facing AR patients with different causes and disease progression, and achieve the goal of achieving correct and effective lifelong management of AR patients.

      Release date:2023-09-28 02:17 Export PDF Favorites Scan
    • Transcatheter aortic valve implantation for native aortic valve regurgitation: A systematic review and meta-analysis

      Objective To evaluate the efficacy of transcatheter aortic valve implantation (TAVI) for native aortic valve regurgitation. MethodsLiterature from The Cochrane Library, PubMed, EMbase, Cochrane Controlled Trials Registry, ClinicalTrials.gov and China Biomedical Literature Database from January 2002 to May 2021 were searched by computer. The literature on TAVI or transcatheter aortic valve replacement treatment for simple aortic reflux were collected. Two reviewers independently screened the literature according to the inclusion and exclusion criteria, extracted data, and assessed the quality of the literature. Meta-analysis was performed using STATA 14.0 software. ResultsA total of 15 studies including 1 394 patients were included. The Newcastle-Ottawa Scales of the studies were≥6 points. The success rate of prosthetic valve implantation was 72.0%-100.0%, and there was no report of serious complications such as surgical death, myocardial infarction, and valve annulus rupture. The 30-day all-cause mortality rate was 6.3% [95%CI (3.4%, 9.1%)]. The incidence of stroke within 30 days and the rate of postoperative permanent pacemaker implantation were 2.0% [95%CI (1.0%, 4.0%)] and 6.0% [95%CI (4.0%, 10.0%)], respectively, and were both within acceptable limits. ConclusionFor patients with simple high-risk aortic regurgitation, TAVI can obtain satisfactory treatment effects and has low postoperative complications rate, and it may be a potential treatment option for such patients.

      Release date:2023-03-01 04:15 Export PDF Favorites Scan
    • Transcatheter aortic valve replacement via vascular access for pure aortic regurgitation: Operational specification for dedicated devices

      This operational specification provides a systematic operational framework for the use of dedicated transvascular devices in transcatheter aortic valve replacement (TAVR) for patients with pure aortic regurgitation (AR). Unlike conventional systems designed for aortic stenosis, AR-specific devices incorporate specialized positioning and anchoring mechanisms that engage the native valve apparatus, effectively addressing the challenge created by the lack of annular calcification. The operational specification outlines indications and patient selection criteria, preprocedural assessment requirements, device design principles and characteristics, step-by-step procedural techniques, and strategies for preventing and managing complications associated with transvascular TAVR using these dedicated systems. The overarching aim is to improve procedural safety and reproducibility, promote broader clinical adoption of AR-specific transvascular TAVR devices, and support the optimization of long-term patient outcomes.

      Release date: Export PDF Favorites Scan
    4 pages Previous 1 2 3 4 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南