• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "mechanical properties" 18 results
    • Design and mechanical properties of biodegradable polymeric stent

      Biodegradable stents (BDSs) are the milestone in percutaneous coronary intervention(PCI). Biodegradable polymeric stents have received widespread attention due to their good biocompatibility, moderate degradation rate and degradation products without toxicity or side effects. However, due to the defects in mechanical properties of polymer materials, the clinical application of polymeric BDS has been affected. In this paper, the BDS geometric configuration design was analyzed to improve the radial strength, flexibility and reduce the shrinkage rate of biodegradable polymeric stents. And from the aspects of numerical simulation, in vitro experiment and animal experiment, the configuration design and mechanical properties of biodegradable polymeric stents were introduced in detail in order to provide further references for the development of biodegradable polymeric stents.

      Release date:2021-02-08 06:54 Export PDF Favorites Scan
    • In Situ Polymerization and Characterization of Hydroxyapatite/polyurethane Implanted Material

      In order to improve the interfacial bonding strength of hydroxyapatite/polyurethane implanted material and dispersion of hydroxyapatite in the polyurethane matrix, we in the present study synthesized nano-hydroxyapatite/polyurethane composites by in situ polymerization. We then characterized and analyzed the fracture morphology, thermal stability, glass transition temperature and mechanical properties. We seeded MG63 cells on composites to evaluate the cytocompatibility of the composites. In situ polymerization could improve the interfacial bonding strength, ameliorate dispersion of hydroxyapatite in the properties of the composites. After adding 20 wt% hydroxyapatite into the polyurethane, the thermal stability was improved and the glass transition temperatures were increased. The tensile strength and maximum elongation were 6.83 MPa and 861.17%, respectively. Compared with those of pure polyurethane the tensile strength and maximum elongation increased by 236.45% and 143.30%, respectively. The composites were helpful for cell adhesion and proliferation in cultivation.

      Release date: Export PDF Favorites Scan
    • Comparative study on the mechanical properties of lower limb arterial stents under various deformation modes

      Lower extremity movement is a complex and large range of limb movement. Arterial stents implanted in lower extremity are prone to complex mechanical deformation, so the stent is required to have high comprehensive mechanical properties. In order to evaluate the mechanical property of different stents, in this paper, finite element method was used to simulate and compare the mechanical properties of six nitinol stents (Absolute Pro, Complete SE, Lifestent, Protégé EverFlex, Pulsar-35 and New) under different deformation modes, such as radial compression, axial compression/tension, bending and torsion, and the radial support performance of the stents was verified by experiments. The results showed that the comprehensive performance of New stent was better than other stents. Among which the radial support performance was higher than Absolute Pro and Pulsar-35 stent, the axial support performance was better than Complete SE, Lifestent and Protégé EverFlex stent, the flexibility was superior to Protégé Everflex stent, and the torsion performance was better than Complete SE, Lifestent and Protégé Everflex stent. The TTR2 type radial support force tester was used to test the radial support performance of 6 types, and the finite element analysis results were verified. The mechanical properties of the stent are closely related to the structural size. The result provides a reference for choosing a suitable stent according to the needs of the diseased location in clinical applications.

      Release date:2021-06-18 04:50 Export PDF Favorites Scan
    • Research on the Mechanical Properties of Bone Scaffold Reinforced by Magnesium Alloy/Bioceramics Composite with Stereolithography Double Channels

      Focusing on the poor mechanical strength of porous bioceramics bone scaffold, and taking into account of the good mechanical properties of biodegradable magnesium alloy, we proposed a novel method to fabricate magnesium alloy/bioceramics composite bone scaffold with stereolithography double channels. Firstly, a scaffold structure without mutually connected double channels was designed. Then, an optimized bioceramics scaffold was fabricated according to stereolithography and gel-casing. Molten AZ31 magnesium alloy was perfused into the secondary channel of scaffold by low-pressure casting, and magnesium alloy/bioceramics composite bone scaffold was obtained when magnesium alloy was solidified. The compression test showed that the strength of bioceramics scaffold with only one channel and without magnesium alloy was (9.76±0.64) MPa, while the strength of magnesium alloy/bioceramics composite scaffold with double channels was (17.25±0.88) MPa. It can be concluded that the magnesium alloy/bioceramics composite is obviously able to improve the scaffold strength.

      Release date:2021-06-24 10:16 Export PDF Favorites Scan
    • SIMPLIFIED PREPARATION AND RELATIVE EVALUATION OF DECELLULARIZED PORCINE AORTICSCAFFOLD

      【Abstract】 Objective To investigate the feasibil ity of applying enzymatic method to prepare decellularizedporcine aorta and to evaluate its biomechanical properties, immunogenicity and cell compatibil ity. Methods 0.1% trypsin- 0.01% EDTA was appl ied to extract cells from porcine aorta under 37 continuously vibrating condition and its histology and microstructure were observed. The thickness, stress-strain curve, ultimate tension stress (UTS) and strain of failure (SOF) were compared before and after decellularization for 48, 96 and 120 hours under uniaxial tensile tests, respectively. The histological change was observed at 1, 3 and 6 weeks after the decellularized tissue was implanted subcutaneously in 3 dogs. According to the HE stains and a semi-quantitative Wakitani grading method, gross changes, category and amounts of infiltrated cells and neo-capillaries were compared between pre- and post-decellularization of porcine aortae. Endothel ial cells from canine external jugular vein were seeded onto the decellularized patches to observe the cell compatibil ity. Results Microscopy and electron microscopies examination identified that cell components was completely removed from the fresh porcine aorta and Masson’ strichrome showed that the structure of matrix (fibrins) was maintained intact at 96 hours using the decellularization method. There were no significant differences in the thickness, UTS and SOF between before and after decellularization (P gt; 0.05). However, The UTS values showed a decrease tendency and SOF showed an increase tendency. The stress-strain curve also verified a decrease tendency in mechanical intensity and an increase one in ductil ity after decellularization. After implanting the acellularized matrix subcutaneously in canine, moderately lymphocyte infiltration was seen at the 1st week and the infiltration was replaced by fibroblasts accompanied by neocapillary formation at the 6th week. A semi-quantity histological evaluation showed that there were differences in gross observation, category and the numbers of the infiltrated cells between decellularized and non-decellularized tissues(P lt; 0.05). A cell monolayer was identified by HE staining and scanning electron microscopywhen the endothel ial cells were seeded onto the inner luminal surface of the scaffold, al igned at the same direction on the whole. Conclusion The decellularized porcine aortic scaffold, prepared by trypsin-EDTA extraction under continuously vibrating condition, could meet the requirements of tissue-engineering graft in biomechanical properties, immunogenicity and cell compatibil ity.

      Release date:2016-09-01 09:10 Export PDF Favorites Scan
    • Characterization of rabbit corneal biomechanical properties after corneal refractive surgery based on rapid loading-unloading uniaxial tensile test

      In order to understand how the biomechanical properties of rabbit cornea change over time after corneal ablation, 21 healthy adult rabbits were used in this study, with the left eye as experimental side and the right eye as the control side. Firstly, a lamellar knife was used to remove a portion of the anterior corneal surface tissue (30%~50% of the original corneal thickness) from the left eye of each rabbit, as an animal model simulating corneal refractive surgery. Secondly, postoperative experimental rabbits were kept for one, three, or six months until being euthanized. Strip specimens were produced using their corneas in vitro to perform a uniaxial tensile test with an average loading-unloading rate of approximately 0.16 mm/s. Finally, the visco-hyperelastic material constitutive model was used to fit the data. The results showed that there was a significant difference in the viscoelastic parameters of the corneas between the experimental and the control eyes at the first and third postoperative months. There was a difference in tangential modulus between the experimental and the control eyes at strain levels of 0.02 and 0.05 at the third postoperative month. There was no significant difference in biomechanical parameters between the experimental and the control eyes at the sixth postoperative month. These results indicate that compared with the control eyes, the biomechanical properties of the experimental eyes vary over postoperative time. At the third postoperative month, the ratio of corneal tangential modulus between the experimental and the control eyes significantly increased, and then decreased. This work lays a preliminary foundation for understanding the biomechanical properties of the cornea after corneal refractive surgery based on rapid testing data obtained clinically.

      Release date:2024-04-24 09:40 Export PDF Favorites Scan
    • Biomechanical advantages of personalized Y-shaped plates in treatment of distal humeral intra-articular fractures

      Objective To compare the biomechanical properties of personalized Y-shaped plates with horizontal plates, vertical plates, and traditional Y-shaped plates in the treatment of distal humeral intra-articular fractures through finite element analysis, and to evaluate their potential for clinical application. Methods The study selected a 38-year-old male volunteer and obtained a three-dimensional model of the humerus by scanning his upper limbs using a 64-slice spiral CT. Four types of fracture-internal fixation models were constructed using Mimics 19.0, Geomagic Wrap 2017, Creo 6.0, and other software: horizontal plates, vertical plates, traditional Y-shaped plate, and personalized Y-shaped plate. The models were then meshed using Hypermesh 14.0 software, and material properties and boundary conditions were defined in Abaqus 6.14 software. AnyBody 7.3 software was used to simulate elbow flexion and extension movements, calculate muscle strength, joint forces, and load torques, and compare the peak stress and maximum displacement of the four fixation methods at different motion angles (10°, 30°, 50°, 70°, 90°, 110°, 130°, 150°) during elbow flexion and extension. Results Under dynamic loading during elbow flexion and extension, the personalized Y-shaped plate exhibits significant biomechanical advantages. During elbow flexion, the peak internal fixation stress of the personalized Y-shaped plate was (28.8±0.9) MPa, which was significantly lower than that of the horizontal plates, vertical plates, and traditional Y-shaped plate (P<0.05). During elbow extension, the peak internal fixation stress of the personalized Y-shaped plate was (18.1±1.6) MPa, which was lower than those of the other three models, with significant differences when compared with horizontal plates and vertical plates (P<0.05). Regarding the peak humeral stress, the personalized Y-shaped plate model showed mean values of (10.9±0.8) and (13.1±1.4) MPa during elbow flexion and extension, respectively, which were significantly lower than those of the other three models (P<0.05). Displacement analysis showed that the maximum displacement of the humerus with the personalized Y-shaped plate during elbow flexion was (2.03±0.08) mm, slightly higher than that of the horizontal plates, but significantly lower than that of the vertical plates, showing significant differences (P<0.05). During elbow extension, the maximum displacement of the humerus with the personalized Y-shaped plate was (1.93±0.13) mm, which was lower than that of the other three models, with significant differences when compared with vertical plates and traditional Y-shaped plates (P<0.05). Stress contour analysis showed that the stress of the personalized Y-shaped plate was primarily concentrated at the bifurcation of the Y-shaped structure. Displacement contour analysis showed that the personalized Y-shaped plate effectively controlled the displacement of the distal humerus during both flexion and extension, demonstrating excellent stability. ConclusionThe personalized Y-shaped plate demonstrates excellent biomechanical performance in the treatment of distal humeral intra-articular fractures, with lower stress and displacement, providing more stable fixation effects.

      Release date:2025-05-13 02:15 Export PDF Favorites Scan
    • Experimental measurement and modeling analysis of active and passive mechanical properties of arterial vessel wall

      Coronary artery diseases (CAD) have always been serious threats to human health. The measurement, constitutive modeling, and analysis of mechanical properties of the blood vessel wall can provide a tool for disease diagnosis, stent implantation, and artificial artery design. The vessel wall has both active and passive mechanical properties. The passive mechanical properties are mainly determined by elastic and collagen fibers, and the active mechanical properties are determined by the contraction of vascular smooth muscle cells (VSMC). Substantial studies have shown that, the two-layer model of the vessel wall can feature the mechanical properties well, and the circumferential, axial and radial strain and stress are of great significance in arterial wall mechanics. This study reviewed recent investigations of mechanical properties of the vessel wall. Challenges and opportunities in this area are discussed relevant to the clinical treatment of coronary artery diseases.

      Release date:2021-02-08 06:54 Export PDF Favorites Scan
    • Biological and Biomechanical Properties of Acellular Porcine Aortic Valve Stabilized by Dye Mediated Photo Oxidation

      Objective To investigate the biological and biomechanical characteristics of acellular porcine aortic valve with dye mediated photo oxidation so that a new and better bioprosthetic valve materials can be obtained. Methods Thirty porcine aortic valves were divided into three groups with random number table. Acellular valves (n=10) were stabilized by dye mediated photo oxidation in dye mediated photo oxidation group; acellular valves (n=10) were stabilized by glutaraldehyde in glutaraldehyde group; and acellular valves (n=10) were acellularized only in acellular valves group. Thickness, appearance, histology, water content, shrinkage temperature, breaking strength and soluble protein level of acellular porcine aortic in three groups were tested respectively. Results There were light blue, soft, flexible and unshrinking valves in dye mediated photo oxidation group. Compared to valves in glutaraldehyde group, valves in dye mediated photo oxidation group had lighter thickness(0.26±0.09mm vs. 0.38±0.08mm,Plt;0.05), more water content(86.30%±4.03% vs. 71.10%±3.23%,Plt;0.05), and lower shrinkage temperature (76.30±0.70℃ vs. 87.70±0.30℃,Plt;0.05); while these indexes had no statistically significant differences compared to those in acellular valves group. At the same time, compared to valves in acellular valves group, valves in dye mediated photo oxidation group had more breaking strength(17.33±2.65 mPa vs. 9.11±0.95 mPa,Plt;0.05) and lower soluble protein level(0.039%±0.013% vs. 0.107%±0.024%,Plt;0.05); while these indexes had no statistically significant differences compared to those in glutaraldehyde group. Conclusion Acellular porcine aortic valve stabilized by dye mediated photo oxidation has nice biological and biomechanical characteristics.

      Release date:2016-08-30 06:08 Export PDF Favorites Scan
    • Effects of SMILE with different residual stromal thicknesses on corneal biomechanical properties of rabbits in vivo

      Femtosecond laser small incision lenticule extraction (SMILE) with different residual stromal thicknesses (RST) is set to investigate its effect on corneal biomechanical properties of rabbits in vivo. In this study, 24 healthy adult Japanese rabbits were randomly divided into group A and B. The RST of group A was set 30% of the corneal central thickness (CCT), and the RST of group B was 50% of the CCT. The thickness of the corneal cap in both groups was set one third of CCT. Corneal visualization Scheimpflug technology (Corvis ST) and Pentacam three-dimensional anterior segment analyzer were used to determine corneal biomechanical and morphological parameters before surgery, and 1 week, 1 month and 3 months after surgery. Pearson correlation analysis was used to analyze factors affecting corneal biomechanical parameters after SMILE. The results showed that the corneal stiffness of group A was significantly higher than that of group B at 1 week and 1 month after surgery, and most biomechanical parameters returned to preoperative levels at 3 months postoperatively. The results of correlation analysis showed that postoperative CCT and RST were the main factors affecting corneal biomechanical parameters after SMILE. There was no significant difference in corneal posterior surface height (PE) between 3 months after surgery and before surgery in both two groups. It indicates that although the ability to resist deformation of cornea decreases in SMILE with thicker corneal cap and less RST, there is no tendency to keratoconus, which may be related to the preservation of more anterior stromal layer.

      Release date:2022-10-25 01:09 Export PDF Favorites Scan
    2 pages Previous 1 2 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南