ObjectiveTo explore the gait trajectory characteristics and effectiveness after unicompartmental knee arthroplasty (UKA).MethodsThirty patients (30 knees) with anterior medial compartment osteoarthritis who were treated with UKA between January 2017 and December 2018 were selected as subjects (UKA group). According to age, gender, and side, 30 patients (30 knees) with knee osteoarthritis treated with total knee arthroplasty (TKA) were selected as control (TKA group). In addition to the range of motion (ROM) before operation showing significant difference between the two groups (t=4.25, P=0.00), there was no significant difference in gender, age, disease duration, sides, body mass index, and preoperative hip-knee-ankle angle (HKA), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score between the two groups (P>0.05). The incision length, drainage volume within 24 hours after operation, and the changes of hemoglobin and albumin were recorded. The WOMAC score, ROM, and HKA before and after operation were compared between the two groups. At 1 year after operation, the gait trajectory characteristics of two groups were analyzed by Vicon three-dimensional gait capture system, and the absolute symmetry index (ASI) of the lower limbs of the two groups was calculated.ResultsThe incisions of the two groups healed by first intention, with no complications. The incision length, drainage volume within 24 hours, and the changes of hemoglobin and albumin after operation in the UKA group were significantly smaller than those in the control group (P<0.05). All patients were followed up completely, the follow-up time ranged from 13 to 20 months of UKA group (mean, 18 months) and 16 to 24 months of control group (mean, 20 months). The imaging review showed that the lower limb alignment of the two groups were restored to a neutral position, and the position of prosthesis was good. At 1 year after operation, the WOMAC score, HKA, and ROM of two groups were significantly improved when compared with those before operation (P<0.05); the postoperative WOMAC score and ROM of the UKA group were significantly better than those of the control group (P<0.05), and there was no significant difference in HKA between the two groups (t=1.54, P=0.13). Gait analysis at 1 year after operation showed that the walking speed, stride length, knee extension at mid-stance, and flexion at swing in the UKA group were significantly better than those in the TKA group (P<0.05); there was no significant difference in cadence, knee flexion at initial contact, and knee flexion at loading response between the two groups (P>0.05). The ASI of bilateral knee flexion in the UKA group was significantly greater than that in the TKA group during the initial contact and loading response period (P<0.05).ConclusionCompared with TKA, UKA has the advantages of small incision, less blood loss, and quicker functional recovery. The early gait after UKA is mainly manifested as the increase in walking speed, stride length, knee flexion at swing, and extension at mid-stance phase. From the analysis of gait symmetry, during the initial contact and loading response phase, the operation side after UKA undertakes more shock absorption and joint stabilization functions than the contralateral side.
Objective To provide the objective basis for the evaluation of the operative results of vascularized greater trochanter bone flap in treating osteonecrosis of the femoral head (ONFH) by three-dimensional gait analysis. Methods Between March 2006 and March 2007, 35 patients with ONFH were treated with vascularized greater trochanter bone flap, and gait analysis was made by using three-dimensional gait analysis system before operation and at 1, 2 years afteroperation. There were 23 males and 12 females, aged 21-52 years (mean, 35.2 years), including 8 cases of steroid-induced, 7 cases of traumatic, 6 cases of alcohol ic, and 14 cases of idiopathic ONFH. The left side was involved in 15 cases, and right side in 20 cases. According to Association Research Circulation Osseous (ARCO) classification, all patients were diagnosed as having femoral-head necrosis at stage III. Preoperative Harris hip functional score (HHS) was 56.2 ± 5.6. The disease duration was 1.5-18.6 years (mean, 5.2 years). Results All incisions healed at stage I without early postoperative compl ications of deep vein thrombosis and infections of incision. Thirty-five patients were followed up 2-3 years with an average of 2.5 years. At 2 years after operation, the HHS score was 85.8 ± 4.1, showing significant difference when compared with the preoperative score (t=23.200, P=0.000). Before operation, patients showed a hip muscles gait, short gait, reduce pain gait, and the pathological gaits significantly improved at 1 year after operation. At 1 year and 2 years after operation, step frequency, pace, step length and hip flexion, hip extension, knee flexion, ankle flexion were significantly improved (P lt; 0.01). Acceleration-time curves showed that negative wave and spinous wave at acceleration-stance phase of front feet and hind feet in affected l imb were obviously reduced at 1 year and 2 years after operation. Postoperative petronas wave appeared at swing phase; the preoperative situation was three normal phase waves. Conclusion These results suggest that three-dimensional gait analysis before and after vascularized greater trochanter for ONFH can evaluate precisely hip vitodynamics variation.
ObjectiveTo explore the gait trajectory characteristics of patients after total knee arthroplasty (TKA) assisted by three-dimensional (3D) printing navigation template.MethodsTwenty female patients (20 knees) with knee osteoarthritis who were treated with TKA assisted by 3D printing navigation template between February 2017 and February 2018 were selected as the 3D printing group. The patients were 50-69 years old, with an average age of 57.2 years. The disease duration was 4-7 years, with an average of 5.6 years. The osteoarthritis was classified as Kellgren-Lawrence Ⅲ level in 5 cases and Ⅳ level in 15 cases. The preoperative hip-knee-ankle angle (HKA) was (170.8±5.6)°. All patients were varus deformity. According to age and affected side, 20 healthy female volunteers were selected as the control group. The volunteers were 51-70 years old, with an average age of 56.7 years. Preoperative HKA was (178.8±0.6)°. There was significant difference in HKA between the two groups (P>0.05). The HKA, Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and visual analogue scale (VAS) scores of the 3D printing group before and after operation were compared. At 6 months after operation, the gait trajectory characteristics of 3D printing group and control group were analyzed by Vicon gait capture system. The kinematics parameters included velocity, cadence, stride length, maximum knee flexion angle (stance), minimum knee flexion angle (stance), maximum knee flexion angle (swing), mean hip rotation angle (stance), mean ankle rotation angle (stance).ResultsThe incisions of 3D printing group healed by first intention, with no complications. All patients were followed up 7-12 months (mean, 9.0 months). The WOMAC and VAS scores at 6 months after operation were significant lower than those before operation (P<0.05). The HKA was (178.8±0.8)° at 4 weeks after operation and the difference was significant when compared with that before operation (t=39.203, P=0.000). The position of the prosthesis was good. The femoral posterior condyle osteotomy line, surgical transepicondylar axis, and patella transverse line were parallel, varus deformity was corrected, and lower limb alignment was restored to neutral position. Gait analysis at 6 months after operation showed that the differences in all kinematics parameters between the two groups were significant (P<0.05).ConclusionAssisted by 3D printing navigation template, TKA can alleviate pain symptoms and correct deformity, with satisfactory early effectiveness. Compared with healthy people, the early postoperative gait of the patients were characterized by decreasing velocity, cadence, stride length, knee flexion range, and increasing compensatory hip and ankle rotation range.
Nowadays, for gait instability phenomenon, many researches have been carried out at home and abroad. However, the relationship between plantar pressure and gait parameters in the process of balance adjustment is still unclear. This study describes the human body adaptive balance reaction during slip events on slippery level walk by plantar pressure and gait analysis. Ten healthy male subjects walked on a level path wearing shoes with two contrastive contaminants (dry, oil). The study collected and analyzed the change rule of spatiotemporal parameters, plantar pressure parameters, vertical ground reaction force (VGRF), etc. The results showed that the human body adaptive balance reaction during slip events on slippery level walk mainly included lighter touch at the heel strikes, tighter grip at the toe offs, a lower velocity, a shorter stride length and longer support time. These changes are used to maintain or recover body balance. These results would be able to explore new ideas and provide reference value for slip injury prevention, walking rehabilitation training design, research and development of walking assistive equipments, etc.
This study aims to establish a multi-segment foot model which can be applied in dynamic gait simulation. The effectiveness and practicability of this model were verified afterwards by comparing simulation results with those of previous researches. Based on a novel hybrid dynamic gait simulator, bone models were imported into automatic dynamic analysis of mechanical systems (ADAMS). Then, they were combined with ligaments, fascia, muscle and plantar soft tissue that were developed in ADMAS. Multi-segment foot model was consisted of these parts. Experimental data of human gait along with muscle forces and tendon forces from literature were used to drive the model and perform gait simulation. Ground reaction forces and joints revolution angles obtained after simulation were compared with those of previous researches to validate this model. It showed that the model developed in this paper could be used in the dynamic gait simulation and would be able to be applied in the further research.
Objective To investigate the changes of knee joint kinematics after anterior cruciate ligament (ACL) reconstruction assisted by personalized femoral positioner based on the apex of deep cartilage (ADC). Methods Between January 2021 and January 2022, a total of 40 patients with initial ACL rupture who met the selection criteria were randomly divided into the study group (using the personalized femoral positioner based on ADC design to assist ACL reconstruction) and the control group (not using the personalized femoral positioner to assist ACL reconstruction), with 20 patients in each group. Another 20 volunteers with normal knee were collected as a healthy group. There was no significant difference in gender, age, body mass index, and affected side between groups (P>0.05). Gait analysis was performed at 3, 6, and 12 months after operation using Opti _ Knee three-dimensional knee joint motion measurement and analysis system, and the 6 degrees of freedom (flexion and extension angle, varus and valgus angle, internal and external rotation angle, anteroposterior displacement, superior and inferior displacement, internal and external displacement) and motion cycle (maximum step length, minimum step length, and step frequency) of the knee joint were recorded. The patients’ data was compared to the data of healthy group. Results In the healthy group, the flexion and extension angle was (57.80±3.45)°, the varus and valgus angle was (10.54±1.05)°, the internal and external rotation angle was (13.02±1.66)°, and the anteroposterior displacement was (1.44±0.39) cm, the superior and inferior displacement was (0.86±0.20) cm, and the internal and external displacement was (1.38±0.39) cm. The maximum step length was (51.24±1.29) cm, the minimum step length was (45.69±2.28) cm, and the step frequency was (12.45±0.47) step/minute. Compared with the healthy group, the flexion and extension angles and internal and external rotation angles of the patients in the study group and the control group decreased at 3 months after operation, and the flexion and extension angles of the patients in the control group decreased at 6 months after operation, and the differences were significant (P<0.05); there was no significant difference in the other time points and other indicators when compared with healthy group (P>0.05). In the study group, the flexion and extension angles and internal and external rotation angles at 6 and 12 months after operation were significantly greater than those at 3 months after operation (P<0.05), while there was no significant difference in the other indicators at other time points (P>0.05). There was a significant difference in flexion and extension angle between the study group and the control group at 6 months after operation (P<0.05), but there was no significant difference of the indicators between the two groups at other time points (P>0.05).Conclusion Compared with conventional surgery, ACL reconstruction assisted by personalized femoral positioner based on ADC design can help patients achieve more satisfactory early postoperative kinematic results, and three-dimensional kinematic analysis can more objectively and dynamically evaluate the postoperative recovery of knee joint.
Aiming at the gait instability phenomenon under disturbed conditions, domestic and foreign scholars have done some research works, but the relationship between the independent balancing act with the surface electromyographic and gait parameters in the process of instability has yet rarely been involved. In this study, using the gait analysis combined with electromyographic signal analysis, we investigated balance adjustment mechanism of joints and muscles of the human lower limb under the condition of walking on the level trail and after foot heel touching the ground and unexpected sliding. Studying 10 healthy subjects with the unified shoes, we acquired and analyzed the changing rule of the lower limb joint torque, joint angle, and the surface electromyographic of the main muscle groups involved in situations of dry or oid trails. Studies showed that when accident sliding happened, the body would increase ankle dorsiflexion torque moment, knee unbend torque and straight angle, and meanwhile increase the torque of hip extension, and timely adjust muscle activation time (Followed by activation of Tibialis anterior muscle→Rectus femoris→Gastrocnemius→Femoral biceps) to adjust the center of gravity, to maintain balance of the body, and to avoid falling down. The results of the research could be used to explore new ideas and to provide a certain reference value for preventing slip damage, rehabilitation training and development of lower limb walker.
The purpose of this study is to determine how restricting inversion-eversion and pronation-supination motions of the ankle joint complex influences the stability of human gait. The experiment was carried out on a slippery level ground walkway. Spatiotemporal gait parameter, kinematics and kinetics data as well as utilized coefficient of friction (UCOF) were compared between two conditions, i.e. with restriction of the ankle joint complex inversion-eversion and pronation-supination motions (FIXED) and without restriction (FREE). The results showed that FIXED could lead to a significant increase in velocity and stride length and an obvious decrease in double support time. Furthermore, FIXED might affect the motion angle range of knee joint and ankle joint in the sagittal plane. In FIXED condition, UCOF was significantly increased, which could lead to an increase of slip probability and a decrease of gait stability. Hence, in the design of a walker, bipedal robot or prosthetic, the structure design which is used to achieve the ankle joint complex inversion-eversion and pronation-supination motions should be implemented.
Gait recognition is a new technology in biometric recognition and medical treatment which has advantages such as long-distance and non-invasiveness. Depending on the differences between different people's walking postures, we can recognize individuals by characteristics extracted from the images of walking movement. A complete gait recognition process usually includes gait sequence acquisition, gait detection, feature extracting and recognition. In this paper, the commonly used methods of these four processes are introduced, and feature extraction methods are classified from different multi-angle views. And then the new algorithm of multi-view emerged in recent years is highlighted. In addition, this paper summarizes the existing difficulties of gait recognition, and looks into the future development trends of it.
In this paper, the research has been conducted by the Microsoft kinect for windows v2 for obtaining the walking trajectory data from hemiplegic patients, based on which we achieved automatic identification of the hemiplegic gait and sorted the significance of identified features. First of all, the experimental group and two control groups were set up in the study. The three groups of subjects respectively completed the prescribed standard movements according to the requirements. The walking track data of the subjects were obtained straightaway by Kinect, from which the gait identification features were extracted: the moving range of pace, stride and center of mass (up and down/left and right). Then, the bayesian classification algorithm was utilized to classify the sample set of these features so as to automatically recognize the hemiplegia gait. Finally, the random forest algorithm was used to identify the significance of each feature, providing references for the diagnose of disease by ranking the importance of each feature. This thesis states that the accuracy of classification approach based on bayesian algorithm reaches 96%; the sequence of significance based on the random forest algorithm is step speed, stride, left-right moving distance of the center of mass, and up-down moving distance of the center of mass. The combination of step speed and stride, and the combination of step speed and center of mass moving distance are important reference for analyzing and diagnosing of the hemiplegia gait. The results may provide creative mind and new references for the intelligent diagnosis of hemiplegia gait.