• <table id="gigg0"></table>
  • west china medical publishers
    Author
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Author "褚楷" 2 results
    • Risk of micro-fracture in femoral head after removal of cannulated screws for femoral neck fracture

      ObjectiveTo explore the changes of bone and risk of micro-fracture in femoral head after removal of cannulated screws following femoral neck fracture healing under the impact force of daily stress.MethodsA total of 42 specimens of normal hip joint were collected from 21 adult fresh cadaveric pelvic specimens. Wiberg central-edge (CE) angle, bone mineral density, diameter of femoral head, neck-shaft angle, and anteversion angle of femoral neck were measured. Then, the 3 cannulated screws were implanted according to the AO recommended method and removed to simulate the complete anatomical union of femoral neck fracture. The morphology of screw canal in the femoral head was observed by CT. Finally, the specimens were immobilized vertically within the impact device in an upside-down manner, and the femoral heads were impacted vertically. Every specimen was impacted at 200, 600, and 1 980 N for 20 times with the impacting device. After impact, every specimen was scanned by CT to observe the morphology changes of screw canal in the femoral head. Micro-fractures in the femoral head could be confirmed when there was change in the morphology of screw canal, and statistical software was used to analyze the risk factors associated with micro-fractures.ResultsAfter impact at 200 and 600 N, CT showed that the morphology of screw canal of all specimens did not change significantly compared with the original. After impact at 1 980 N, there were protrusion and narrowing in the screw canal of the 22 femoral head specimens (11 pelvic specimens), showing obvious changes compared with the original screw canal, indicating that there were micro-fractures in the femoral head. The incidence of micro-fracture was 52.38% (11/21). logistic regression results showed that there was correlation between micro-fracture and bone mineral density (P= 0.039), but no correlation was found with CE angle, diameter of femoral head, neck-shaft angle, and anteversion angle (P>0.05).ConclusionThe micro-fractures in the femoral head may occur when the femoral head is impacted by daily activities after removal of cannulated screws for femoral neck fractures, and such micro-fractures are associated with decreased bone density of the femoral head.

      Release date:2020-09-28 02:45 Export PDF Favorites Scan
    • EyresⅢA型喙突骨折的手術治療

      目的 總結Eyres ⅢA型喙突骨折手術治療方法及效果。 方法 2010年8月-2014年8月,采用鎖骨鉤鋼板固定肩關節聯合喙突骨折解剖復位后2枚空心釘固定治療4例Eyres ⅢA型喙突骨折患者。男3例,女1例;年齡36~41歲,平均39歲。致傷原因:交通事故傷3例,機器傷1例。傷后至入院時間2~12 h,平均6 h。 結果 術后患者切口均Ⅰ期愈合,無感染、皮膚壞死等術后早期并發癥發生。4例均獲隨訪12個月。術后4個月取出鎖骨鉤鋼板,保留空心釘。術后8個月CT示骨折完全愈合。隨訪期間無肩關節再脫位,內固定物松動、斷裂,繼發骨折等發生。術后12個月根據Neer肩關節功能評分標準評分為83~87分,平均85分。 結論 對于Eyres ⅢA型喙突骨折,采用鎖骨鉤鋼板固定肩關節聯合喙突骨折解剖復位后2枚空心釘固定可行且療效滿意。

      Release date: Export PDF Favorites Scan
    1 pages Previous 1 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南