The "bayonet" deformity from poliomyelitis is a peculiar type of deformity of knee. From January 1986 through December 1994, 23 cases of this type of knee deformity were corrected by surgery. The operative procedures performed were suprachondylar osteotomy of femur or subplateau osteotomy of tibia. The patients were followed up from 1 to 5 years, with an average of 3 years. The result rated excellent to good was 95.6%. The features of this disorder and the main points in the surgical procedure were discussed.
The applied anatomy of the skin supplied by the lateral genicular artery was studied on 52 specimens of adult extremities: This skin area had a quite constant and reliable blood supply from the artery. The blood supply to this skin area was giving rise from the superior lateral genicular artery and had numerous anastomosis with the lateral femoral circumflex artery, cutaneous branch of the popliteal artery and the inferior lateral artery. The caliber of the supplying artery, its length and the area distribussed.
Objective To investigate a modified robotized hydraulictensor for management of the ligament balance in the total knee arthroplasty. Methods The effect of the modified robotized hydraulic tensor on the mechanical behaviour of the ligament system balance in the total knee arthroplasty was analyzed andthe related information was obtained. Results The robotized hydraulic tensor acted as a tensorsensor system, which could assist the surgeon by providing thequantitative information to align the lower limb in extension, equalize the articular spaces in extension and flexion, balance the internal and external forces, and define the femoral component rotation, and by providing the information toplan the releasing of the soft tissues and the rotating of the femoral component. Conclusion The modified robotized hydraulic tensor can enable the surgeon to properly manage the ligament balance in the total knee arthroplasty.
From 1984 to 1993, 49 cases with varioussoft tissue defects around the knee were treated with pedicled calf myocutaneous flap, lateral sural cutaneous artery island skin flap, saphenous neurovascularskin flap and fasciocutaneous flap. The postoperation results were sucessful in 47 cases, and failure 2 cases, in one case with flap infection and theother with scar formation surrounding the knee. Both the failure cases were cured with split skin graft. The patient were followed up for an average of three and a halfyears, the knee function was almost completely regained, and the blood supply of the flaps, the elasticity and colour of the flaps were similiar to that of the normal skin, without being cumbersome. The sensation of the saphenous neurovascular flaps and the lateral suralcutaneous artery island flaps was preserved, except partial numbness was presented at the distal part of the flaps. Operative indications and selection of cases were discussed.
Objective To explore the relationship of the limited resource of the autologous bone marrow mesenchymal stem cells (MSCs) in articularcavity to the treatment results of full-thickness articular cartilage defect, and to investigate whether the extrogenous sodium hyaluronate(SH) promotes the migration of MSCs cultured in vitro tothe articular defect in vivo. Methods Sixty-six Japan rabbits were made the model of the full-thickness articular cartilage defect (5 mm width and 4 mm depth).The autologous MSCs were extracted from the rabbit femur, cultured in vitro, labeledby Brdu, and injected into the injured articular cavity with or without SH. Theexperiment was divided into 4 groups; group A (MSCs and SH, n=15); group B (MSCs, n=15); group C (SH, n=18); and group D (non-treatment, n=18). The morphologic observation was made by HE staining, Mallory staining and immunohistochemical staining after 5 weeks, 8 weeks and 12 weeks of operation. Results There were significant differences in the thickness of repairing tissue between group A and group B(Plt;0.01); but there were no significant differences between group A and group C, and between group B and group D(P>0.05). Thehistological observation showed that the main repairing tissue was fibrocartilage in group A and fiber tissue in group B. Conclusion MSCs cultured in vitro and injected into the articular cavity can not improve the treatment results of the articular cartilage defect. Extrogenous SH has effect on repairing cartilage defect. The extrogenous SH has no effect on the chemotaxis of the MSCs, and on the collection of MSCs into the joint defect.
Objective To investigate the rotational mismatch of total kneereplacement with medial 1/3 of tibial tuberosity as bony landmark in osteoarthritic patients with varus or valgus deformity. Methods Axial images on computed tomography of 62 knees (including 55 varus deformities and 7 valgus deformities) in 32 Chinese osteoarthritic patients who had total knee arthroplasty were analyzed, compared with that of 10 healthy knees. On images of the distal femur, the angle between the lines of surgical epicondylar axis(SEA) and posterior condylar axis was measured as posterior condylar angle (PCA), and on images of the proximal tibia, a baseline for the anteriorposterior axis of each component was drawn based on the SEA for the femur and the medial 1/3 of the tibial tuberosity for the tibia. The angle between these lines (Angle α) was defined as therotational mismatch between the components when they were aligned to the anatomic landmarks of each bone. Results The sulcus of medial epicondyle of femur could be identified on CT images of over 80% osteoarthritic knees; the median value of PCA was +2.36°, with an individual variation of 0° to +7.5°. Angle α was +6.45±3.68°(range, 0° to +11.8°) in 10 healthy knees, which increased significantly to +10.85±10.47°(range, 0° to +28.1°)in 55 varus knees (P<0.05), which also increased significantly to +11.6±7.3°(range, -6.5° to +26.8°) in 7 valgus knees (P< 0.05). Conclusion With the medial 1/3 of the tibial tuberosity as the rotational landmark for the tibial component, there was a tendency to align the tibial component in external rotational position relative to the femoral component in knees with normal alignment, the rotational mismatch increased in Chinese osteoarthritic knees with varus and valgus deformity.
Knee osteoarthritis (KOA) is one of the common degenerative joint diseases, which is more common in the middle-aged and elderly population. It shows significant gender differences, with a significantly higher incidence rate in women than in men, seriously affecting the quality of life of patients. However, there are few research reports on the correlation between gender differences and the incidence of KOA both domestically and internationally. Therefore, this article will summarize and analyze the potential causes of gender differences related to the incidence of KOA from five aspects: hormone levels, anatomical biomechanical characteristics, genes, obesity, and exercise-muscle factors. Through a comprehensive review of research progress, the aim is to provide a theoretical basis for gender based personalized treatment of KOA in clinical practice.
Objective To study the diagnosis and treatment of the acute medial collateral ligament ruptures of the knee.Methods From August 1998 to August 2003, 87 cases of acute medial collateral ligament ruptures were examined with physical method and MR imaging. Out of them, 35 cases of Ⅰdegree and Ⅱ degree ruptures were treated with non-surgery and 52 cases of Ⅲ degree ruptures were treated surgically. The torn medial collateral ligaments were mended, 21 of which were strengthened with the anterior partial gracilis muscle tendon after the arthroscopy. Results In 35 cases of Ⅰ and Ⅱ degree ruptures, 32 were followed up 13 months on average. According to Lysholm scoring system, the clinical results were classified as excellent or good in 93.7% of the cases. In 52 cases of Ⅲ degree ruptures, 50 were followed up 16 months on average. The excellent or good result was 90%.Conclusion For Ⅰ and Ⅱ degree ruptures, MR imagimg is an important way to definitely- diagnose medial collateral ligament ruptures. Abduction stress test of knee extension shows that the medial direct instability is a main way to definitely diagnose Ⅲ degree ruptures. The results of conservative treatment of Ⅰ degree and Ⅱ degree ruptures are excellent. Surgical therapy are fitfor the cases of Ⅲ degree ruptures.
ObjectiveTo investigate the correlation between graft maturity and knee function after anterior cruciate ligament (ACL) reconstruction.MethodsA total of 50 patients who underwent ACL reconstruction with autologous tendons between August 2016 and August 2018 were included in the study. There were 28 males and 22 females, with an average age of 31.0 years (range, 18-50 years). At 6 months and 2 years after operation, the signal to noise quotient (SNQ) values of tibial and femoral ends of graft were measured by MRI, and the mean value was taken as the SNQ value of graft. The function of knee joint was evaluated by Tegner, Lysholm, and International Knee Documentation Committee (IKDC) scores. The differences in SNQ values between tibial and femoral ends were analyzed at 6 months and 2 years after operation. The correlation between SNQ value at 6 months after operation and knee function score at 2 years after operation was analyzed. According to SNQ value at 6 months after operation, the patients were divided into group A (SNQ value≥12) and group B (SNQ value<12) and the correlation between SNQ value and knee function score was further analyzed.ResultsAll incisions healed primarily without infection or injury of blood vessels and nerves. All patients were followed up 24-28 months (mean, 26.6 months). The IKDC, Lysholm, and Tegner scores at 6 months and 2 years after operation were significantly higher than those before operation (P<0.05), and all scores at 2 years after operation were also significantly higher than those at 6 months (P<0.05). The SNQ values at 6 months and 2 years after operation were 12.517±6.272 and 10.900±6.012, respectively, and the difference was significant (t=1.838, P=0.007). The SNQ values of graft at 6 months after operation were significantly different from those at 2 years after operation (P<0.05), and the SNQ values of tibial and femoral ends of graft at the same time point were significantly different (P<0.05). The SNQ value of 50 patients at 6 months after operation was negatively correlated with Lysholm, IKDC, and Tegner scores at 2 years after operation (r=–0.965, P=0.000; r=–0.896, P=0.000; r=–0.475, P=0.003). The patients were divided into groups A and B according to the SNQ value, each with 25 cases; the SNQ values of the two groups at 6 months after operation were negatively correlated with Lysholm, IKDC, and Tegner scores at 2 years after operation (P<0.05).ConclusionAfter ACL reconstruction, the knee function scores and graft maturity of patients gradually improved. The lower the SNQ value in the early stage, the higher the knee function score in the later stage. The SNQ value of MRI in the early stage after ACL reconstruction can predict the knee function in the later stage.