    find Author "王冬青" 4 results
    • 16例重癥心瓣膜病患者的圍手術期處理

      Release date:2016-08-30 06:34 Export PDF Favorites Scan
    • 國產二尖瓣成形環在心瓣膜成形外科中的應用

      目的 評價國產二尖瓣成形環在心瓣膜成形外科中的療效.方法 回顧1986年12月~1995年9月在全身麻醉中度低溫體外循環下用國產二尖瓣成形環行成形術36例,其中二尖瓣成形28例次,三尖瓣成形9例次.結果 住院死亡4例.術后發生低心排血量綜合征5例,呼吸功能不全2例,行氣管切開1例,突發心室顫動3例,多器官功能衰竭2例,腦栓塞1例.隨訪31例無死亡.經超聲心動圖檢查32個成形瓣膜,未見反流5例,輕度反流23例,中度以上反流2例,輕度狹窄2例.跨瓣壓差<1.07kPa(8mmHg)24例,1.07~1.73kPa(8~13mmHg)8例.結論 國產二尖瓣成形環在心瓣膜成形外科中具有重要地位.

      Release date:2016-08-30 06:35 Export PDF Favorites Scan
    • Effect of Exogenous Creatine Phosphate on Energy Metabolism and Mitochondrial Function in Isolated Rat Hearts

      Objective\ To study the mechanism of myocardial protection of exogenous creatine phosphate (CP) against ischemia reperfused injury in modified isolated perfused working rat heart model.\ Methods\ Seventy two rats were divided into five groups.The rat hearts of five groups undergone Langendorff perfused were arrested and made totally ischemic for 40 minutes at 37℃ and reperfused for 20 minutes. St.Thomas cardioplegic solution wasn’t used in group A;It was used immediately after ischemia in group B and grou...

      Release date:2016-08-30 06:35 Export PDF Favorites Scan
    • 3D Hemodynamic Numerical Simulation of Carotid Artery Aneurysm Before and after Surgery Based on CT Date

      Hemodynamic situation is an important factor of recurrence of postoperative carotid artery aneurysm. In order to investigate the hemodynamic factors of postoperative carotid artery aneurysm affect carotid artery aneurysm recurrence, we established a 3D finite element carotid artery aneurysm for the preoperative and postoperative periods using the three-dimensional reconstruction techniques. And then we measured the hemodynamic factors of carotid artery aneurysm of preoperative and postoperative by the finite element method. The carotid artery aneurysm model has an accurate and realistic shape; the pressure of the recurrence of aneurysm was reduced significantly after surgery,wall shear stress increased significantly at residual neck, and blood flow velocity increased significantly, which will increase the risk of recurrence. The hemodynamic analysis provides a reference for development of aneurysm clinical treatment programs and prevention of recurrence.

      Release date: Export PDF Favorites Scan