• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "typing" 32 results
    • Dynamic investigation on biological and molecular biological characteristics of SO-Rb50cloned cell strains

      Objective To compare the differences of chromosome aberration and Rb 1 gene mutation among 3 cloned cells of SO-Rb50 cell line of retinoblastoma. Methods 1.Three cell cloned strains named MC2, MC3, MC4 were isolated from SO-Rb50. 2. Gbanding and karyotype analysis were performed on the llth passage cells of the 3 cell strains.3.All exons and the promoter region of the Rb gene were detected by PCR-SSCP analysis in tumor cell DNA extracted from the 3 cell strains. Results 1.Both numerical and structural chromosomal aberrations could be observed in these 3 cell strains.Several kinds of structural chromosomal aberrations were observed.The chromosome aberrations in the same passage of different cell strains were different.Aberration of chromosome 13 was rare and the aberration feature was different in the 3 cell strains.Five marker chromosomes were identified.M1,t(1;1)qter-p35∷q24-ter could befound in all cell strains.Two of them M4 and M5,have not been reported in SO-Rb50 cell line previously.2.SSCP analysis of exon 24 showed that MC411 and MC3138 had abnormal band. Conclusions The characteristics of heterogeneity of the original tumor cell line SO-Rb50are still kept during a long-term culture in vitro and the cloned strains had dynamic changes during this period.Aberration of chromosome 13 is not the only cause of RB;aberration of chromosome 1,a commom event in some neoplasias as well as in SO-Rb50, plays a meaningful role in the immortalization of this cell line. (Chin J Ocul Fundus Dis, 1999, 15: 146-148)

      Release date:2016-09-02 06:07 Export PDF Favorites Scan
    • RECONSTRUCTION OF MANDIBULAR BONE DEFECTS USING THREE-DIMENSIONAL SKULL MODEL AND INDIVIDUALIZED TITANIUM PROSTHETICS FROM COMPUTER ASSISTED DESIGN

      【Abstract】 Objective To evaluate the feasibility and effectiveness of reconstruction of mandibular bone defects using three-dimensional skull model and individualized titanium prosthetics from computer assisted design. Methods Between July 2002 and November 2009, 9 patients with mandibular defects accepted restorative operation using individualized bone prosthetics. Among 9 cases, 4 were male and 5 were female, aged 19-55 years. The causes of mandibulectomy were benign lesions in 8 patients and carcinoma of gingival in 1 patient. Mandibular defects exceeded midline in 2 cases, involved condylar in 4 cases, and was limited in one side without involvement of temporo-mandibular joint in 3 cases. The range of bone defects was 9.0 cm × 2.5 cm-17.0 cm × 2.5 cm. The preoperative spiral CT scan was performed and three-diamensional skull model was obtained. Titanium prosthetics of mandibular defects were designed and fabricated through multi-step procedure of reverse engineering and rapid prototyping. Titanium prosthetics were used for one-stage repair of mandibular bone defects, then two-stage implant denture was performed after 6 months. Results The individualized titanium prosthetics were inserted smoothly with one-stage operative time of 10-23 minutes. All the cases achieved incision healing by first intention and the oblique mandibular movement was corrected. They all got satisfactory face, had satisfactory contour and good occlusion. In two-stage operation, no loosening of the implants was observed and the abutments were in good position with corresponding teeth which were designed ideally before operation. All cases got satisfactory results after 1-9 years of follow-up. At last follow-up, X-ray examinations showed no loosening of implants with symmetry contour. Conclusion Computer assisted design and three-dimensional skull model techniques could accomplish the design and manufacture of individualized prosthetic for the repair of mandibular bone defects.

      Release date:2016-08-31 04:21 Export PDF Favorites Scan
    • Genotyping and naming rules of Mycobacterium tuberculosis

      Mycobacterium tuberculosis is the causative agent of human tuberculosis. Through the genotyping of Mycobacterium tuberculosis, we can find the epidemic situation and characteristics of tuberculosis in time, analyze the transmission chain between patients in different jurisdictions, and formulate effective intervention measures in time, to provide a strong basis for clinical diagnosis and treatment. At present, several genotyping techniques for Mycobacterium tuberculosis have their advantages and disadvantages in application. This article reviews the genotyping technology, population genetics and genotyping naming rules of Mycobacterium tuberculosis.

      Release date:2022-12-23 09:29 Export PDF Favorites Scan
    • Identification and management of hepatic artery variation in laparoscopic panc-reaticoduodenectomy: a report of 9 cases

      Objective To explore the hepatic artery variations encountered in laparoscopic pancreaticoduodenectomy (LPD) surgery and its significance. Methods The clinical datas of 26 patients who underwent LPD from January 2020 to January 2023 were retrospectively collected. Preoperative evaluation of hepatic artery variability and its types based on relevant clinical and imaging data, as well as targeted measures taken during surgery, and patients’ prognosis were analyzed. Results According to preoperative abdominal enhanced CT, arterial computer tomography angiography imaging and intraoperative skeletonization of the hepatoduodenal ligament, hepatic artery variation was found in 9 of 26 patients undergoing LPD. The left hepatic artery was substituted in 1 case, the right hepatic artery was substituted in 2 cases, 2 cases were the left accessory hepatic artery, and the common hepatic artery originated from the superior mesenteric artery in 3 cases. There was 1 case, right hepatic artery coming from the abdominal aorta, whose arterial variation was not included in the traditional typing. The variant hepatic artery from superior mesenteric artery was separated by posterior approach during operation, and the variant hepatic artery from left gastric artery was separated by anterior approach during operation. Nine patients with hepatic artery variation recovered well after operation, and no serious complications occurred. Conclusions Various hepatic artery variations during LPD need to be carefully evaluated before surgery. During surgery, it should be determined whether to retain the mutated blood vessel based on its diameter and changes in liver blood flow after occlusion, so that reasonable operation can be performed during the operation to avoid hepatic artery damage.

      Release date: Export PDF Favorites Scan
    • Analysis of Preoperative Diagnosis and Surgical Treatment Strategies for Different Types of Mirizzi Syndrome (Report of 86 Cases)

      Objective To analyze the preoperative diagnosis and the operative methods for different types of Mirizzi syndrome (MS). Methods Eighty-six cases of MS confirmed by operation were enrolled from March 1990 to December 2008. Their laboratory examination results and X-ray appearances of endoscopic retrograde cholangiopancreatography (ERCP) were analyzed as well as B-ultrasonography (B-us), CT scan and magnetic resonance cholangiopancreatography (MRCP). According to the Csendes typing, different operative methods were adopted. Results The final diagnosis rate by ERCP for MS attained approximately 85.71% (48/56) in contrast with 17.44% (15/86) by B-us, with 9.52% (4/42) by CT scan and with 71.88%(23/32) by MRCP. Twenty cases were Csendes type Ⅰ, 43 cases were type Ⅱ, 17 cases were type Ⅲ, and 6 cases were type Ⅳ. According to the Csendes typing, the cases of type Ⅰ were treated by for the cholecystectomy or partial resection for reserving the neck of gallbladder, type Ⅱ by fistula reparation and laying up the T type drainage-tube under the fistula, and type Ⅲ and type Ⅳ by the hepaticocholangiojejunostomy and hepaticoduodenostomy. Conclusion The preoperative diagnosis for MS is very difficult, B-us may be acted as an accessory diagnostic method. ERCP and MRCP can improve the rate of preoperative diagnosis for MS strikingly. The best reasonable method of the operative therapy is selected according to the different pathologic type of MS.

      Release date:2016-09-08 10:58 Export PDF Favorites Scan
    • Single-Tube Polymerase Chain Reaction Amplification Protocol for SequencingBased Typing of Human Leukocyte Antigen DRB1

      【Abstract】ObjectiveTo develop a new singletube polymerase chain reaction amplification (ST Amp) protocol for the efficient sequencing-based typing (SBT) of human leukocyte antigen DRB1(HLA-DRB1).MethodsA set of 7 group-specific exonic 5′ amplification primers and a single generic 3′ primer were included together in a single PCR mix to facilitate a single PCR amplification per sample for HLA-DRB1 typing.ResultsAll samples were successfully typed, the typing result was accurate and repeatable.ConclusionST Amp technique has resulted in the ability to perform high-resolution, high-specificity and high-throughput HLA-DRB1 typing by DNA sequencing.

      Release date:2016-09-08 11:54 Export PDF Favorites Scan
    • COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS

      ObjectiveTo study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. MethodsOne adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. ResultsAccording to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. ConclusionCustomized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.

      Release date: Export PDF Favorites Scan
    • APPLICATION OF THREE-DIMENSIONAL PRINTING TECHNIQUE IN ORTHOPAEDICS

      ObjectiveTo review the current progress of three-dimensional (3-D) printing technique in the clinical practice, its limitations and prospects. MethodsThe recent publications associated with the clinical application of 3-D printing technique in the field of surgery, especially in orthopaedics were extensively reviewed. ResultsCurrently, 3-D printing technique has been applied in orthopaedic surgery to aid diagnosis, make operative plans, and produce personalized prosthesis or implants. Conclusion3-D printing technique is a promising technique in clinical application.

      Release date: Export PDF Favorites Scan
    • Progress in early identification of high-grade lung adenocarcinoma

      [Abstract]High-grade histologic subtypes of lung adenocarcinoma, such as micropapillary and solid patterns, are characterized by high invasiveness, increased risk of recurrence, and poor prognosis. Early preoperative identification of these subtypes is crucial for achieving individualized treatment and improving clinical outcomes. This review summarizes the clinical features, imaging manifestations, molecular mechanisms, and diagnostic advances related to these aggressive patterns. Studies have shown that micropapillary and solid subtypes are more common in male smokers, often present as solid nodules, and demonstrate strong predictive value in FDG-PET metabolic parameters and CT-based radiomics models. At the molecular level, EGFR mutations are more frequently observed in micropapillary types, whereas solid subtypes are often associated with high PD-L1 expression and TP53 mutations, indicating distinct therapeutic strategies for targeted and immunotherapies. In addition, serum markers such as CEA and CYFRA21-1, along with inflammatory indices like NLR and SII, may serve as auxiliary tools for subtype identification. Histologic subtypes of lung adenocarcinoma are evolving from descriptive classifications into critical determinants of treatment decisions and precision management. Clinicians should incorporate comprehensive histologic evaluation into individualized therapeutic planning. Multimodal integration technologies, combined with artificial intelligence algorithms, are advancing the accurate preoperative prediction and management of high-risk subtypes, thereby facilitating early diagnosis and stratified treatment of lung adenocarcinoma.

      Release date: Export PDF Favorites Scan
    • Biomechanical study of knee joint based on coronal plane alignment of the knee

      Objective To establish a finite element model of the knee joint based on coronal plane alignment of the knee (CPAK) typing method, and analyze the biomechanical characteristics of different types of knee joints.Methods The finite element models of the knee joint were established based on CT scan data of 6 healthy volunteers. There were 5 males and 1 female with an average age of 24.2 years (range, 23-25 years). There were 3 left knees and 3 right knees. According to the CPAK typing method, the knees were rated as types Ⅰ to Ⅵ. Under the same material properties, boundary conditions, and axial loading, biomechanical simulations were performed on the finite element model of the knee joint. Based on the Von Mises stress nephogram and displacement nephogram, the peak stresses of the meniscus, femoral cartilage, and tibial cartilage, and the displacement of the meniscus were compared among different types of knee joints. Results The constructed finite element model of the knee joint was verified to be effective, and the stress and displacement results were consistent with previous literature. Under the axial load of 1 000 N, the stress nephogram showed that the stress distribution of the medial and lateral meniscus and tibial cartilage of CPAK type Ⅲ knee joint was the most uneven. The peak stresses of the lateral meniscus and tibial cartilage were 9.969 6 MPa and 2.602 7 MPa, which were 173% and 165% of the medial side, respectively. The difference of peak stress between the medial and lateral femoral cartilage was the largest in type Ⅳ knee joint, and the medial was 221% of the lateral. The displacement nephogram showed that the displacement of the medial meniscus was greater than that of the lateral meniscus except for types Ⅲ and Ⅵ knee joints. The difference between medial and lateral meniscus displacement of type Ⅲ knee joint was the largest, the lateral was 170% of the medial. Conclusion In the same type of joint line obliquity (JLO), the medial and lateral stress distribution of the knee was more uniform in varus and neutral positions than in valgus position. At the same time, the distal vertex of JLO subgroup can help to reduce the uneven medial and lateral stress distribution of varus knee, but increase the uneven distribution of valgus knee.

      Release date: Export PDF Favorites Scan
    4 pages Previous 1 2 3 4 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南