• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "three-dimensional printing technology" 16 results
    • Research progress of tissue engineering technology in promoting revascularization of necrotic femoral bone tissue

      ObjectiveTo summarize the research progress of tissue engineering technology to promote bone tissue revascularization in osteonecrosis of the femoral head (ONFH).MethodsThe relevant domestic and foreign literature in recent years was extensively reviewed. The mechanism of femoral head vascularization and the application progress of tissue engineering technology in the promotion of ONFH bone tissue revascularization were summarized.ResultsRebuilding or improving the blood supply of the femoral head is the key to the treatment of ONFH. Tissue engineering is a hot spot in current research. It mainly focuses on the three elements of seed cells, scaffold materials, and angiogenic growth factors, combined with three-dimensional printing technology and drug delivery systems to promote the revascularization of the femoral bone tissue.ConclusionThe strategy of revascularization of the femoral head can improve the local blood supply and delay or even reverse the progression of ONFH disease.

      Release date:2021-12-07 02:45 Export PDF Favorites Scan
    • Preliminary application of three dimensional printing personalized navigation template in assisting total elbow replacement for patients with elbow tumor

      Objective To explore the clinical methods of resection of elbow tumor and total elbow replacement with custom personalized prosthesis based on three dimensional (3-D) printing navigation template. Methods In August 2016, a 63-year-old male patient with left elbow joint tumor was treated, with the discovery of the left distal humerus huge mass over 3 months, with elbow pain, activity limitation of admission. Computer-assisted reduction technique combined with 3-D printing was used to simulate preoperative tumor resection, a customized personal prosthesis was developed; tumor was accurately excised during operation, and the clinical result was evaluated after operation. Results The time was 46 minutes for tumor resection, and was 95 minutes for personalized implant and allograft bone without fluoroscopy. X-ray and CT examination at 1 week after operation showed good position of artificial elbow joint; the anteversion of ulna prosthesis was 30° and the elbow carrying angle was 15°, which were consistent with the simulated results before surgery. The finger flexion was normal at 1 month after operation; the range of motion was 0-130° for elbow flexion and extension, 80° for forearm pronation, and 80° for forearm supination. The elbow function was able to meet the needs of daily life at 7 months after operation, and no recurrence and metastasis of tumor were observed. Conclusion For limb salvage of elbow joint, computer aided design can make preoperative surgical simulation; the navigation template can improve surgical precision; and the function of elbow joint can be reconstructed with customized and personlized prosthesis for total elbow replacement.

      Release date:2017-04-12 11:26 Export PDF Favorites Scan
    • Treatment of unstable pelvic fractures by cannulated screw internal fixation with the assistance of three-dimensional printing insertion template

      ObjectiveTo evaluate the effectiveness of unstable pelvic fractures treated by cannulated screw internal fixation with the assistance of three-dimensional (3D) printing insertion template.MethodsThe clinical data of 10 patients who underwent surgical treatment for unstable pelvic fractures by cannulated screw internal fixation with the assistance of 3D printing insertion template between May 2015 and June 2016 were retrospectively analysed. There were 7 males and 3 females with an average age of 37.5 years (range, 20-58 years). The causes of injury included falling from height in 5 cases, crushing from heavy load in 1 case, and traffic accidents in 4 cases. The interval from injury to admission was 1-5 hours (mean, 3.1 hours). The fracture situation included 6 cases of sacral fracture, 1 case of right sacroiliac joint dislocation, and 3 cases of iliac bone fracture. There were 10 cases of superior and inferior pubic rami fracture, including 3 cases on the left side (2 cases of suprapubic fracture adjacent to symphysis pubis), 2 cases on the right side, and 5 cases on the bilateral. All fractures were classified according to the Tile system, there were 4 cases of type B2, 1 of type B3, 4 of type C1, and 1 of type C2. The radiological outcome was evaluated by Matta scale, and the positions of the iliosacral screw and superior pubic ramus screw were evaluated according to 3D reconstruction of CT postoperatively. The functional outcome was evaluated by Majeed function scale.ResultsThe average time of each screw implantation was 30 minutes, and the average blood loss per screw incision was 50 mL. The time of implantation of each sacroiliac screw was 24-96 seconds (mean, 62 seconds), and the time of implantation of each suprapubic screw was 42-80 seconds (mean, 63.2 seconds). The hospitalization duration was 17-90 days (mean, 43.7 days). All incisions healed by first intention. All patients were followed up 12-22 months (mean, 15.6 months). The radiological outcome was excellent in 8 cases and good in 2 cases according to Matta scale; and 3D reconstruction of CT demonstrated that all the 9 iliosacral screws were placed as type Ⅰ, and all the 13 suprapubic ramus screws were placed as grade 0 on the first postoperative day. No complication such as neurovascular injury, screw back out or rupture, or secondary fracture displacement was observed during the follow-up. At 6 months after operation, the X-ray films showed good fracture healing in all the 10 patients. The functional outcome was excellent in 9 cases and good in 1 case according to Majeed scale at 1 year after operation. One patient sustained Tile C2 pelvic disruption complicated with L5 nerve root injury achieved complete nervous functional recovery at last follow-up.ConclusionIt has advantages of precise screw insertion and lower risk of neurovascular injury to treat unstable pelvic fractures by cannulated screw internal fixation with the assistance of 3D printing insertion template, which can be a good alternative for the treatment of unstable pelvic fractures.

      Release date:2018-02-07 03:21 Export PDF Favorites Scan
    • Research on three-dimensional printing technology based on three-dimensional multimodality imaging to assist the operation of malignant bone tumors of limbs

      Objective To explore the role and effectiveness of three-dimensional (3D) printing technology based on 3D multimodality imaging in surgical treatment of malignant bone tumors of limbs. Methods The clinical data of 15 patients with malignant bone tumors of the limbs who met the selection criteria between January 2016 and January 2019 were retrospectively analyzed. There were 6 males and 9 females, with a median age of 34 years (range, 17-73 years). There were 5 cases of osteosarcoma, 3 cases of chondrosarcoma, 2 cases of Ewing sarcoma, 1 case of hemangiosarcoma, 1 case of ameloblastoma, and 3 cases of metastatic carcinoma. The tumors were located in the humerus in 5 cases, ulna in 2 cases, femur in 3 cases, and tibia in 5 cases. The disease duration was 2-8 months (median, 4 months). Preoperative 3D multimodality imaging was administered first, based on which computer-assisted preoperative planning was performed, 3D printed personalized special instruments and prostheses were designed, and in vitro simulation of surgery was conducted, successively. Two cases underwent knee arthroplasty, 2 had semi-shoulder arthroplasty, 2 had proximal ulna arthroplasty, and 9 had joint-preserving surgery. Surgical margins, operation time, intraoperative blood loss, surgical complications, Musculoskeletal Tumor Society (MSTS) score, and oncological outcome were collected and analyzed. Results All 15 patients completed the operation according to the preoperative plan, and the surgical margins were all obtained wide resection margins. The operation time was 80-240 minutes, with a median of 150 minutes. The intraoperative blood loss was 100-400 mL, with a median of 200 mL. There was no significant limitation of limb function due to important blood vessels or nerves injury during operation. One case of superficial infection of the incision was cured after dressing change, and the incisions of the other patients healed by first intention. All patients were followed up 6-48 months, with a median of 24 months. Two of the patients died of lung metastasis at 6 and 24 months after operation, respectively. No local recurrence, prosthesis dislocation, or prosthesis loosening occurred during follow-up. At last follow-up, the MSTS score ranged from 23 to 30, with an average of 25. Conclusion3D printing tecnology, based on 3D multimodality imaging, facilitates precise resection and reconstruction for malignant bone tumors of limbs, resulting in improved oncological and functional outcome.

      Release date:2022-08-04 04:33 Export PDF Favorites Scan
    • Research progress on three-dimensional printed interbody fusion cage

      Spinal fusion is a standard operation for treating moderate and severe intervertebral disc diseases. In recent years, the proportion of three-dimensional printing interbody fusion cage in spinal fusion surgery has gradually increased. In this paper, the research progress of molding technology and materials used in three-dimensional printing interbody fusion cage at present is summarized. Then, according to structure layout, three-dimensional printing interbody fusion cages are classified into five types: solid-porous-solid (SPS) type, solid-porous-frame (SPF) type, frame-porous-frame (FPF) type, whole porous cage (WPC) type and others. The optimization process of three-dimensional printing interbody fusion cage and the advantages and disadvantages of each type are analyzed and summarized in depth. The clinical application of various types of 3D printed interbody fusion cage was introduced and summarized later. Lastly, combined with the latest research progress and achievements, the future research direction of three-dimensional printing interbody fusion cage in molding technology, application materials and coating materials is prospected in order to provide some reference for scholars engaged in interbody fusion cage research and application.

      Release date:2021-12-24 04:01 Export PDF Favorites Scan
    • Application of individualized transiliac crest nail-grafting guide plate in deep pelvic external fixator implantation

      Objective To explore the application of individualized transiliac crest nail-grafting guide plate prepared by computer-aided design and three-dimensional (3D) printing technology in deep pelvic external fixator implantation. Methods Five patients with pelvic fractures were collected between May 2017 and February 2018. There were 4 females and 1 male with an average age of 52 years (range, 29-68 years). Pelvic fractures were classified as type B in 3 cases and type C in 2 cases by Tile classification. The interval between injury and operation was 6-14 days (mean, 9 days). The preoperative CT images of pelvic fractures were collected. The data was reconstructed by 3D imaging reconstruction workstation. An individualized transiliac crest nail-grafting guide plate was designed on the virtual 3D model. The individualized transiliac crest nail-grafting guide plate and the solid pelvic model were produced with the 3D printing technology. The individualized transiliac crest nail-grafting guide plate was used for intraoperative deep pin position on iliac crest after the preoperative simulation. The follow-up CT scans were used to determine the differences in distance from anterior superior iliac spine, convergence angle, and caudal angle between the preoperative plan and postoperative measurement. Results During the operation, the individualized transiliac crest nail-grafting guide plate was used to guide the placement of 20 pins. X-ray film and CT examination showed that all pins were well positioned. The average depth of pins was 83.16 mm (range, 70.13-100.53 mm). Fitted 3D reconstruction images showed that the entry point and orientation of the pins were all consistent with preoperative schemes. Compared with the planned nail path, there was no significant difference in the distance from anterior superior iliac spine, convergence angle, and caudal angle in the actual nail path (P>0.05). No loosening and rupture of pin, no damage of blood vessels and nerve, and shallow or deep infection occurred during 3 months follow-up, and the incisions healed by first intention. All patients were satisfied with the treatment process. The ranges of motion of hip and knee were normal, and the visual analogue scale (VAS) score was 0-3 (mean, 0.5). Conclusion The individualized transiliac crest nail-grafting guide plate technique is the improvement of traditional technique. It can increase accuracy and effective depth of pin position, enable patients to obtain pelvic mechanical stability quickly after operation, and reduce the risk of complications related to nail path.

      Release date:2019-08-23 01:54 Export PDF Favorites Scan
    • Construction of a novel tissue engineered meniscus scaffold based on low temperature deposition three-dimenisonal printing technology

      Objective To investigate the construction of a novel tissue engineered meniscus scaffold based on low temperature deposition three-dimenisonal (3D) printing technology and evaluate its biocompatibility. Methods The fresh pig meniscus was decellularized by improved physicochemical method to obtain decellularized meniscus matrix homogenate. Gross observation, HE staining, and DAPI staining were used to observe the decellularization effect. Toluidine blue staining, safranin O staining, and sirius red staining were used to evaluate the retention of mucopolysaccharide and collagen. Then, the decellularized meniscus matrix bioink was prepared, and the new tissue engineered meniscus scaffold was prepared by low temperature deposition 3D printing technology. Scanning electron microscopy was used to observe the microstructure. After co-culture with adipose-derived stem cells, the cell compatibility of the scaffolds was observed by cell counting kit 8 (CCK-8), and the cell activity and morphology were observed by dead/live cell staining and cytoskeleton staining. The inflammatory cell infiltration and degradation of the scaffolds were evaluated by subcutaneous experiment in rats. Results The decellularized meniscus matrix homogenate appeared as a transparent gel. DAPI and histological staining showed that the immunogenic nucleic acids were effectively removed and the active components of mucopolysaccharide and collagen were remained. The new tissue engineered meniscus scaffolds was constructed by low temperature deposition 3D printing technology and it had macroporous-microporous microstructures under scanning electron microscopy. CCK-8 test showed that the scaffolds had good cell compatibility. Dead/live cell staining showed that the scaffold could effectively maintain cell viability (>90%). Cytoskeleton staining showed that the scaffolds were benefit for cell adhesion and spreading. After 1 week of subcutaneous implantation of the scaffolds in rats, there was a mild inflammatory response, but no significant inflammatory response was observed after 3 weeks, and the scaffolds gradually degraded. Conclusion The novel tissue engineered meniscus scaffold constructed by low temperature deposition 3D printing technology has a graded macroporous-microporous microstructure and good cytocompatibility, which is conducive to cell adhesion and growth, laying the foundation for the in vivo research of tissue engineered meniscus scaffolds in the next step.

      Release date:2024-06-14 09:52 Export PDF Favorites Scan
    • Clinical application of accurate placement of lumbar pedicle screws using three-dimensional printing navigational templates under Quadrant system

      Objective To explore the feasibility and the effectiveness of the accurate placement of lumbar pedicle screws using three-dimensional (3D) printing navigational templates in Quadrant minimally invasive system. Methods The L1-5 spines of 12 adult cadavers were scanned using CT. The 3D models of the lumbar spines were established. The screw trajectory was designed to pass through the central axis of the pedicle by using Mimics software. The navigational template was designed and 3D-printed according to the bony surface where the soft tissues could be removed. The placed screws were scanned using CT to create the 3D model again after operation. The 3D models of the designed trajectory and the placed screws were registered to evaluate the placed screws coincidence rate. Between November 2014 and November 2015, 31 patients with lumbar instability accepted surgery assisted with 3D-printing navigation module under Quadrant minimally invasive system. There were 14 males and 17 females, aged from 42 to 60 years, with an average of 45.2 years. The disease duration was 6-13 months (mean, 8.8 months). Single segment was involved in 15 cases, two segments in 13 cases, and three segments in 3 cases. Preoperative visual analogue scale (VAS) was 7.59±1.04; Oswestry disability index (ODI) was 76.21±5.82; and the Japanese Orthopaedic Association (JOA) score was 9.21±1.64. Results A total of 120 screws were placed in 12 cadavers specimens. The coincidence rate of placed screw was 100%. A total of 162 screws were implanted in 31 patients. The operation time was 65-147 minutes (mean, 102.23 minutes); the intraoperative blood loss was 50-116 mL (mean, 78.20 mL); and the intraoperative radiation exposure time was 8-54 seconds (mean, 42 seconds). At 3-7 days after operation, CT showed that the coincidence rate of the placed screws was 98.15% (159/162). At 4 weeks after operation, VAS, ODI, and JOA score were 2.24±0.80, 29.17±2.50, and 23.43±1.14 respectively, showing significant differences when compared with preoperative ones (t=14.842,P=0.006;t=36.927,P=0.002;t=–36.031,P=0.001). Thirty-one patients were followed up 8-24 months (mean, 18.7 months). All incision healed by first intention, and no complication occurred. During the follow-up, X-ray film and CT showed that pedicle screw was accurately placed without loosening or breakage, and with good fusion of intervertebral bone graft. Conclusion 3D-printing navigational templates in Quadrant minimally invasive system can help lumbar surgery gain minimal invasion, less radiation, and accurate placement.

      Release date:2017-03-13 01:37 Export PDF Favorites Scan
    • Treatment of severe distal humeral bone defects with three-dimensional printing technology

      ObjectiveTo explore the application of three-dimensional (3D) printing technology in precise and individualized surgical treatment of severe distal humeral bone defect.MethodsFive patients with severe distal humeral bone defects were treated with customized 3D printing prostheses between December 2010 and December 2015. There were 4 males and 1 female, with an age of 23-57 years (mean, 35 years); and the length of the bone defect was 5-12 cm (mean, 8 cm). The cause of injury was mechanical injury in 2 cases and strangulation in 3 cases. All of them were the open fracture of Gustilo type Ⅲ. There were 2 cases of radial fracture, 1 case of cubital nerve injury, and 3 cases of radial nerve injury. The time from injury to one-stage operation was 6-18 hours (mean, 10 hours). The operation time, intraoperative blood loss, and intraoperative fluoroscopy were recorded. During follow-up, the anteroposterior and lateral X-ray films of the elbow joints were performed to identify whether there was prosthesis loosening; Mayo Elbow Performance Score (MEPS) and upper extremity Enneking score were used to evaluate limb function.ResultsThe operation time was 140-190 minutes (mean, 165 minutes). The intraoperative blood loss was 310-490 mL (mean, 415 mL). The intraoperative fluoroscopy was 1-3 times (mean, 1.6 times). Five patients were followed up 14-38 months (mean, 21 months). The wound exudate occurred in 1 case and cured after anti-inflammatory local dressing change; the subcutaneous hematoma occurred in 1 case, and improved after color Doppler ultrasound guided puncture and drainage. The MEPS scores and the Enneking scores were all significantly improved when compared with preoperative ones (P<0.05). Except MEPS score between 6 and 12 months after operation had no significant difference (P>0.05), there were significant differences in MEPS scores and Enneking scores between the other time points (P<0.05). During the follow-up, no prosthetic loosening or joint dislocation occurred.Conclusion3D printing technology can achieve personalized treatment of severe distal humeral bone defects, obtain relatively good elbow joint function, and has less postoperative complications and satisfactory effectiveness.

      Release date:2018-12-04 03:41 Export PDF Favorites Scan
    • Application of a new point contact pedicle navigation template as an auxiliary screw implant in scoliosis correction surgery

      ObjectiveTo explore the effectiveness of a new point contact pedicle navigation template (referred to as “new navigation template” for simplicity) in assisting screw implantation in scoliosis correction surgery. MethodsTwenty-five patients with scoliosis, who met the selection criteria between February 2020 and February 2023, were selected as the trial group. During the scoliosis correction surgery, the three-dimensional printed new navigation template was used to assist in screw implantation. Fifty patients who had undergone screw implantation with traditional free-hand implantation technique between February 2019 and February 2023 were matched according to the inclusion and exclusion criteria as the control group. There was no significant difference between the two groups (P>0.05) in terms of gender, age, disease duration, Cobb angle on the coronal plane of the main curve, Cobb angle at the Bending position of the main curve, the position of the apical vertebrae of the main curve, and the number of vertebrae with the pedicle diameter lower than 50%/75% of the national average, and the number of patients whose apical vertebrae rotation exceeded 40°. The number of fused vertebrae, the number of pedicle screws, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were compared between the two groups. The occurrence of implant complications was observed. Based on the X-ray films at 2 weeks after operation, the pedicle screw grading was recorded, the accuracy of the implant and the main curvature correction rate were calculated. ResultsBoth groups successfully completed the surgeries. Among them, the trial group implanted 267 screws and fused 177 vertebrae; the control group implanted 523 screws and fused 358 vertebrae. There was no significant difference between the two groups (P>0.05) in terms of the number of fused vertebrae, the number of pedicle screws, the pedicle screw grading and accuracy, and the main curvature correction rate. However, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were significantly lower in trial group than in control group (P<0.05). There was no complications related to screws implantation during or after operation in the two groups. ConclusionThe new navigation template is suitable for all kinds of deformed vertebral lamina and articular process, which not only improves the accuracy of screw implantation, but also reduces the difficulty of operation, shortens the operation time, and reduces intraoperative bleeding.

      Release date:2023-06-07 11:13 Export PDF Favorites Scan
    2 pages Previous 1 2 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南