• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "monitor" 122 results
    • Analysis of 598 Cases of Nosocomial Infection in a New Comprehensive Hospital

      ObjectiveTo understand the characteristics of and risk factors for nosocomial infection in a newly built branch of a university teaching hospital, in order to investigate the control measures for prevention and control of nosocomial infection. MethodsA total of 598 cases of nosocomial infection from April 2012 to June 2014 were enrolled in this study. We analyzed statistically such indexes as nosocomial infection rate, infection site, pathogen detection, and use of antibiotics. Meantime, infection point-prevalence survey was introduced by means of medical record checking and bedside visiting. ResultsAmong all the 44 085 discharged patients between April 2012 and June 2014, there were 598 cases of nosocomial infection with an infection rate of 1.36%. Departments with a high nosocomial infection rate included Intensive Care Unit (ICU) (9.79%), Department of Orthopedics (2.98%), Department of Geriatrics (2.62%), and Department of Hematology (1.64%). The top four nosocomial infection sites were lower respiratory tract (45.32%), urinary tract (13.21%), operative incision (8.86%), and blood stream (8.86%). The samples of 570 nosocomial infections were delivered for examination with a sample-delivering rate of 95.32%. The most common pathogens were acinetobacter Baumanii (17.02%), Klebsiella pneumoniae (14.21%), Escherichia coli (13.68%), Pseudomonas aeruginosa (11.93%), and Staphylococcus aureus (9.12%). And urinary tract intubation (42.81%), admission of ICU (28.60%), and application of corticosteroid and immunosuppressive agents (26.42%) were the top three independent risk factors for nosocomial infection. ConclusionGeneral and comprehensive monitoring is an effective method for the hospital to detect high-risk departments, factors and patients for nosocomial infection, providing a theoretical basis for prevention and control of nosocomial infection.

      Release date:2016-10-02 04:54 Export PDF Favorites Scan
    • Immunosuppressive Treatment and Immunological Monitoring after Cardiac Transplantation

      Abstract: Cardiac transplantation is an effective therapeutic method for terminalstage heart diseases. The immunosuppressive treatment based on calcineurin inhibitors (CsA and FK506) is most commonly used, monoclonal antibodies are also used in some recipients as induction therapy before and/or after transplantation. Some new immunosuppressive drugs, such as Rapamycin and Everolimus, can not only inhibit the acute transplant rejection but also prevent cardiac vasculopathy. The application of some relatively nontraumatic tests, such as immunological indexes, cardiac markers and other serological parameters, are helpful for diagnosis and preventing postcardiac transplant rejection at early stage and improving the result of cardiac transplantation.

      Release date:2016-08-30 06:13 Export PDF Favorites Scan
    • Analysis on the Microbial Monitoring Results of Transfusion Service

      摘要:目的:回顧我院輸血科近年醫院感染監測結果,總結經驗方法,保障輸血生物安全。 方法:收集2001年至今的微生物監測報告,計算合格率。結果:各監測項目的合格率不同,儲血冰箱內壁在90次監測中合格率達100%,冰箱空氣及儲血室空氣監測的合格率波動較大。結論:目前的消毒方式可以保障輸血科微生物監測合格,杜絕院感發生。Abstract: Objective: To sum up experiences of biosecurity measures in transfusion service of our hospital by retrospect the microbial monitoring results. Methods: Collecting the monitoring reports on microorganism since 2001 and figuring out the percent of pass. Results: The percent of pass are different, the interior of refrigerator is up to 100% while others fluctuate. Conclusion: Current measurements can meet the requirement and provide the guarantee for safe transfusion.

      Release date:2016-09-08 10:12 Export PDF Favorites Scan
    • Home versus ambulatory versus office blood pressure monitoring in diagnosis and management of hypertension

      ObjectiveTo compare home blood pressure monitoring (HBPM) versus ambulatory blood pressure monitoring (ABPM) versus office blood pressure monitoring (OBPM) in diagnosis and management of hypertension, and to find the optimal blood pressure measurement and management.MethodsThe following were compared among three BP monitoring, such as cost-effectiveness, prognostic value of target organ damage (TOD), predictive value of the progress in chronic kidney disease (CKD) and blood pressure variety (BPV). ResultsCompared to OBPM, ABPM was the most cost-effective method in the primary diagnosis of hypertension, but HBPM was the optimal method in long-term and self-management in hypertension. In hypertensives, compared to OBPM, HBPM and ABPM, especially HBPM, had a stronger predictive value for cardiovascular events, stroke, end-stage renal dysfunction (ESRD) and all-cause mortality. In hypertensives with renal dysfunction, controlling HBPM and ABPM, especially controlling ABPM, was an effective way to slow the progress in renal dysfunction, to decrease cardiovascular events, and to decrease the need of dialysis. All BPV derived from OBPM, ABPM and HBPM had a predictive significance of cardiovascular events, and HBPM BPV performed the best.ConclusionCompared to OBPM, ABPM is the best method in primary diagnosis of hypertension and BP control in CKD patients, while HBPM is the best method in predicting and in evaluating BPV, as well as in long-term and self-management in hypertension.

      Release date:2020-03-13 01:50 Export PDF Favorites Scan
    • Self-management of Anticoagulation Monitoring for Patients Following Mechanical Heart Valve Replacement: A non-randomized Controlled Trial

      Objective To discuss the application value in increasing the frequency of monitoring and ensuring the safety of anticoagulation therapy in patient self-monitoring (PST) and self-management (PSM) of portable coagulometer. Method This non-randomized prospective controlled study was conducted in 100 patients receiving oral warfarin anticoagulation therapy after heart valve replacement and met the inclusion criteria in our hospital between March 2013 and April 2014 year. All the patients were divided into three groups including an outpatient follow-up group(outpatient group), a self-monitoring group and a self-management group. Meanwhile, the patients in the outpatient group visited professional institutions, performed international normalized ratio (INR) testing with central lab and adjusted the dosage of orally administered warfarin by the doctors. And the other two groups performed INR testing with CoaguChek XS portable coagulometer by themselves, and the patients in the self-management group performed management by themselves. The follow-up time was 6 months. The dates of time in therapeutic range (TTR), fraction of time in therapeutic range (FTTR) and anticoagulation complications in the three groups were analyzed and compared. Results There was no significant difference in the INR results obtained from the follow-up time among the three groups (P=0.845) . TTR value of INR of the outpatient group, the self-monitoring group, and the self-management group was 45.9% (4368.0 days/9517.0 days), 61.2% (6057.0 days/9897.0 days), and 65.4% (2833.8 days/4333.0 days), respectively with a statistical difference among the three groups (P<0.001) . FTTR value of INR obtained from the outpatient group, the self-monitoring group, and the self-management group was 48.3% (99 times/205 times), 60.7% (164 times/270 times), and 64.9% (100 times/154 times) respectively. There was a statistical difference in the FTTR between the outpatient group and the self-monitoring group (P=0.007) , and also between the outpatient group and the self-monitoring group (P=0.002) . But there was no statistical difference between the self-monitoring group and the self-management group (P=0.392) . There were not any major bleeding and thrombosis complications in all study. And there was no statistical difference in the total complications, thrombosis, and bleeding complications rates between the outpatient group and the self-monitoring group, and also between the outpatient group and the self-management group (P>0.05) . Conclusions The patients receiving oral anticoagulation after heart valve replacement or their care providers were able to perform PST and PSM. The use of portable coagulometer for self-monitoring and self-management can increase the frequency of anticoagulation monitoring and achieve better INR target value control. PST and PSM could achieve higher quality of anticoagulation management and life and without increasing the risk of oral anticoagulation than the traditional monitoring method. The monitoring frequency of once a month is reasonable for the patients receiving oral anticoagulation more than half a year after heart valve replacement.

      Release date: Export PDF Favorites Scan
    • Continuous improvement of adverse drug reaction monitoring in a major public hospital’s cooperating branch hospital

      Objective To investigate the method and effect of continuous improvement of adverse drug reaction (ADR) monitoring in a major public hospital’s cooperating branch hospital. Methods PDCA cycle management was used to continuously improve the quality of ADR monitoring. ADR report network platform was established in the fourth quarter of 2014; ADR report specification training for the medical personnel was held in the first quarter of 2015; a examine mechanism was built in the second quarter of 2015. The quality and quantity of ADR monitoring before and after the PDCA cycle management were analyzed. Results ADR report timeliness conform to the requirements increased from 45.5% (from the first to third quarter of 2014) to 98.1% (from the fourth quarter of 2014 to the second quarter of 2015); accurate ADR types checking, normal name writting, and complete process description increased from 68.6%, 65.7%, 8.6% (from January 2014 to Frequency 2015) to 92.9%, 96.4%, 85.7% (from March to June 2015); the quantity of ADR report was obviously improved. Conclusion Learning from public hospital’s experience and considering its own condition in ADR monitoring, cooperating branch hospital utilizes PDCA cycle management which could continuously improve the ADR monitoring.

      Release date:2017-12-25 06:02 Export PDF Favorites Scan
    • Advances in Intraoperative Neuromonitoring During Thyroid or Parathyroid Surgery

      ObjectiveTo introduce the advances of intraoperative neuromonitoring (IONM) during thyroid or parathyroid surgery. MethodsThe literatures about IONM during thyroid or parathyroid surgery in recent years at home and abroad were collected and reviewed. ResultsIONM is improved from invasive to noninvasive:endotracheal intubation with electrode on its surface. Standardized procedures of IONM is developed. Intermittent monitoring is replaced by continuous monitoring. The monitoring of external branch of superior laryngeal nerve is also a supplement to laryngeal recurrent nerve. With the aid of IONM, non-recurrent laryngeal nerve could be identified easily, also injury spot, and damage degree. We could speculate probable damage mechanisms and prevent irreversible nerve damage through IONM. ConclusionsIONM could be an effective technique to reduce the risk of recurrent laryngeal nerve injury during thyroid or parathyroid surgery, especially in complex surgery and reoperations, which could predict the postoperative function of laryngeal recurrent nerve, and help to avoid severe postoperative complications.

      Release date: Export PDF Favorites Scan
    • Accuracy of Newer-generation Home Blood Glucose Meter in Patients with IGR and Newly-diagnosed Type 2 Diabetes Mellitus

      Objective To evaluate the accuracy of newer-generation home blood glucose meter (Accu-Check? Integra) in patients with impaired glucose regulation (IGR) and newly-diagnosed type 2 diabetes mellitus. Methods A cross-sectional study was performed on 109 cases with newly-diagnosed type 2 diabetes or IGR who were asked to take oral glucose tolerance test (OGTT), while paired samples, that were Accu-Check? Integra in capillary blood glucose (CBG) and laboratory glucose in venous plasma glucose (VPG ), were taken simultaneously. Taking VPG as the reference value, the accuracy of the home glucose meter was assessed according to the international standardization organization (ISO), including, the accuracy was studied by means of Median absolute difference (Median AD) and Median absolute relative difference (Median RAD), the consistency of CBG and VPG was studied by Clarke Error Grid analysis, the correlation of CBG and VPG was analyzed according to liner regression analysis, and the sensitivity and specificity for hyperglycemia were also calculated. Results There were 292 VPG values paired with CBG values, among which 93.49% of CBG values met ISO home glucose meter criteria, the median AD was 7.2 mg/dL, and the median RAD was 4.76%. Paired glucose measurements from the Accu-Check Integra meter and laboratory glucose measurement demonstrated that 100% of paired points in the overall subject population fell in zones A and B of the Clarke Error Grid. The CBG value was well correlated to VPG value in the overall level, and the sensitivity and specificity were 94.6% and 95.7% respectively for hyperglycemia. Conclusion The newer-generation home blood glucose meter (Accu-Check? Integra) demonstrates a high degree of accuracy, and it can precisely report the real value of blood glucose.

      Release date:2016-09-07 10:59 Export PDF Favorites Scan
    • Three-dimensional spine morphology measuring technology for daily surface monitoring

      In order to conduct surface monitoring of the three-dimensional spine morphology of the human body in daily life, a spine morphology measuring method using "single camera, multi-view" to construct stereo vision is proposed. The images of the back of the human body with landmarks of spinous process are captured from multiple angles by moving a single camera, and based on the "Zhang Zhengyou calibration method" and the triangulation principle of binocular stereo vision, the spatial conversion matrices corresponding to each other between all images and the 3D coordinates of the landmarks are calculated. Then the spine evaluation angle used to evaluate the spine morphology is further calculated. The tests’ results showed that the spine evaluation angle error of this method is within ±3°, and the correlation between the results and the X-ray film Cobb angles is 0.871. The visual detection algorithm used in this paper is non-radioactive, and because only one camera is used in the measurement process and there is no need to pre-set the camera's shooting pose, the operation is simple. The research results of this article can be used in a mobile phone-based intelligent detection system, which will be suitable for the group survey of scoliosis in communities, schools, families and other occasions, as well as for the long-term follow-up of confirmed patients. This will provide a reference for doctors to diagnose the condition, predict the development trend of the condition, and formulate treatment plans.

      Release date:2020-12-14 05:08 Export PDF Favorites Scan
    • Target Monitoring and Analysis of Ventilator-associated Pneumonia in Intensive Care Unit

      ObjectiveTo observe the effect of target monitoring on the patients with ventilator-associated pneumonia (VAP) in intensive care unit (ICU), analyze the risk factors and take effective measures to reduce the VAP occurrence. MethodsTarget monitoring was performed on patients with ventilator in ICU from January to July 2013 (observation group), and they were compared with those patients accepting general comprehensive monitoring in ICU from January to July 2012 (control group). The incidence of VAP was compared between the two groups. ResultsThe incidence of VAP in the observation group and the control group was 21.73‰ and 53.33‰, respectively. There was a significant difference between the observation group and the control group (P<0.05). ConclusionFor patients undergoing mechanical ventilation, target monitoring can control the risk factors and incidence of VAP, adjust the interference in time, and improve the curing rate.

      Release date: Export PDF Favorites Scan
    13 pages Previous 1 2 3 ... 13 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南