    find Keyword "locking plate" 31 results
    • Effectiveness analysis of distal radius microplate locking plate for treatment of displaced fracture of medial clavicle

      ObjectiveTo investigate and evaluate the effectiveness of the distal radius microplate locking plate for the treatment of displaced fracture of medial clavicle.MethodsBetween January 2013 and June 2017, 18 cases of obvious displaced fracture of medial clavicle were treated with distal radius microlocking plate. There were 10 males and 8 females, with an average age of 51.4 years (range, 18-88 years). Causes of injury included traffic accident injury in 15 cases, heavy object injury in 3 cases; all of them were closed injury. According to Edinburgh classification, 15 cases were ⅠB1 type and 3 cases were ⅠB2 type. Fracture displacement was 12-21 mm (mean, 16.3 mm). The time from injury to operation was 3-7 days (mean, 4.3 days). After operation, the clinical healing and complications of fracture were observed, and shoulder function was evaluated according to Rockwood’s scoring criteria.ResultsNo incisional infection, neurovascular injury, or other early complications occurred. All 18 patients were followed up 8-15 months (mean, 12 months). All fractures reached clinical osseous union, and the healing time was 8-24 weeks (mean, 16.6 weeks). Postoperative plate loosening occurred in 1 case, which was removed surgically, while other patients did not suffer from complications such as bone nonunion, displacement, internal fixator loosening, and loss of reduction. At last follow-up, according to Rockwood’s scoring criteria, the results were excellent in 12 cases and good in 6 cases.ConclusionThe distal radius microplate locking plate is effective for the treatment of displaced medial clavicle fracture, which has few complications, and is feasible for early functional exercise, and is helpful for the recovery of shoulder joint function.

      Release date:2019-05-06 04:48 Export PDF Favorites Scan
    • A meta-analysis of the necessity of coracoclavicular ligament reconstruction in the treatment of unstable distal clavicular fractures with locking plate

      Objective To investigate the necessity of coracoclavicular ligament reconstruction in the treatment of unstable distal clavicular fracture with locking plate. Methods We searched PubMed, the Cochrane Library, Embase, China National Knowledge Infrastructure, Wanfang database and VIP database for all the articles about the treatment of unstable distal clavicular fractures using locking plate combined with coracoclavicular ligament reconstruction or locking plate alone from the establishment of databases to November 30th, 2022. According to the inclusion and exclusion criteria, we selected the documents that met the requirements of this paper, and extracted the effective data after evaluating the quality of the documents, including the Constant-Murley score, coracoclavicular distance, fracture healing time, complication rate, operative time, intraoperative blood loss, incision length and the Visual Analogue Scale score of postoperative pain. RevMan 5.4 software was used for meta-analysis. Results A total of 11 retrospective cohort studies were included, and the overall quality of the literature was high. A total of 421 cases were included in this study, including 209 cases in the locking plate combined with coracoclavicular ligament reconstruction group and 212 cases in the locking plate group. The results of meta-analysis showed that locking plate combined with coracoclavicular ligament reconstruction in the treatment of unstable distal clavicular fractures was superior to locking plate alone in the Constant-Murley score [mean difference (MD)=7.35, 95% confidence interval (CI) (2.84, 11.87), P=0.001], coracoclavicular distance [MD=–1.22 mm, 95%CI (–1.92, –0.53) mm, P=0.0006], fracture healing time [MD=–2.76 weeks, 95%CI (–4.74, –0.79) weeks, P=0.006] and complication rate [odds ratio=0.31, 95%CI (0.14, 0.68), P=0.004], but the former had longer operative time [MD=9.27 min, 95%CI (4.53, 14.01) min, P=0.0001]. There was no significant difference in the intraoperative blood loss [MD=3.31 mL, 95%CI (–17.01, 23.63) mL, P=0.75], incision length [MD=0.30 cm, 95%CI (–0.11, 0.71) cm, P=0.15], or Visual Analogue Scale score of postoperative pain [MD=–0.26, 95%CI (–0.79, 0.27), P=0.33]. Conclusions Although the reconstruction of the coracoclavicular ligament increases the time of surgery, locking plate combined with coracoclavicular ligament reconstruction in the treatment of unstable distal clavicular fractures is significantly better than locking plate alone in terms of reduction quality, shoulder function recovery, fracture healing time, and the incidence of complications, without significant intraoperative bleeding, prolonged incision or postoperative pain.

      Release date:2023-06-21 09:43 Export PDF Favorites Scan
    • Flexible internal fixation with locking plate for distal femoral fractures

      Objective To analyze the effectiveness of flexible internal fixation with locking plate for distal femoral fractures. Methods Between January 2015 and June 2016, 21 cases of distal femoral fractures were treated. There were 5 males and 16 females with an average age of 62 years (range, 32-88 years). Injury was caused by falling in 14 cases, by traffic accident in 5 cases, and by falling from height in 2 cases. The fractures located at the left side in 13 cases and the right side in 8 cases. Twenty cases were fresh closed fractures and 1 case was open fracture. According to AO/Association for the Study of Internal Fixation (AO/OTA) typing, there were 5 cases of type 33-A1, 3 of type 33-A2, 8 of type 33-A3, 2 of type 33-C2, and 3 of type 33-C3. The time from injury to operation was 3-13 days (mean, 6.5 days). Results All operation incisions healed primarily. Eighteen patients were followed up 12-24 months (mean, 16 months). All fractures healed, and the healing time was 8-24 weeks (mean, 16.6 weeks). The articular surface was smooth and the thigh length was recovered. No screw loosening, plate breakage, valgus or varus of the knee, stiff of the knee or non-unions occurred during follow-up. There was no significant difference in visual analogue scale (VAS) score between at 6 and 12 months after operation (P>0.05), and the difference was significant bewteen the other time points (P<0.05). There were significant differences in the range of motion of knee between 1 month and 3, 6, 12 months (P<0.05); there was no significant difference between 3, 6, and 12 months (P>0.05). There were significant differences in the Neer scores between 1, 3, 6, and 12 months after operation (P<0.05). According to Neer score criteria, the results were excellent in 12 cases and good in 6 cases at 12 months after operation. Conclusion Flexible internal fixation with locking plate for distal femoral fractures can get good functional recovery.

      Release date:2018-01-09 11:23 Export PDF Favorites Scan
    • Current status and progress of locking plate in the treatment of distal femoral comminuted fracture

      ObjectiveTo review the current status and progress of locking plate for the treatment of distal femoral comminuted fractures.MethodsThe related literature was extensively reviewed to summarize the current status and progress in the treatment of distal femoral comminuted fracture with locking plate from four aspects: the current treatment situation, the shortcomings of locking plate and countermeasures, the progress of locking technology, locking plate and digital orthopedic technology.ResultsTreatment of distal femoral comminuted fractures is challenging. Locking plates, the most commonly used fixation for distal femoral comminuted fractures, still face a high rate of treatment failure. Double plates can improve the mechanical stability of comminuted fractures, but specific quantitative criteria are still lacking for when to choose double plates for fixation. The far cortial locking screw has shown good application value in improving the micro-movement and promoting the growth of callus. The biphasic plating is a development of the traditional locking plate, but needs further clinical examination. As an auxiliary means, digital orthopedic technology shows a good application prospect.ConclusionThe inherent defect of locking plate is a factor that affects the prognosis of distal femoral comminuted fracture. The optimization of locking technology combined with digital orthopedic technology is expected to reduce the failure rate of treatment of distal femoral comminuted fracture.

      Release date:2021-10-28 04:29 Export PDF Favorites Scan
    • Effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture

      ObjectiveTo summarize the effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture.MethodsBetween January 2011 and October 2016, 25 cases with comminuted Jones fracture were treated with mini locking plate combined with Kirschner wire. There were 9 males and 16 females with an average age of 31.4 years (range, 16-66 years). The fractures located on the left side in 11 cases and on the right side in 14 cases. The causes of injury included spraining in 21 cases, falling down in 3 cases, and bruise in 1 case. The bone fragment of all cases was more than 3 pieces. The fracture line was mostly Y-shape or T-shape. Twelve of them were combined with other fractures. The time from injury to operation was 1-9 days (mean, 5 days). The mini locking plate and Kirschner wire were removed at 9-12 months postoperatively. At 12 months postoperatively, the pain was evaluated by the visual analogue scale (VAS) score, and the function by the American Orthopaedic Foot & Ankle Society (AOFAS) score.ResultsAll incisions healed by first intention. All cases were followed up 12-36 months with an average of 21.7 months. Fracture union was observed in all patients without complications such as nonunion, delayed union, and malunion. The fracture union time was 8-12 weeks (mean, 9.4 weeks). At 12 months postoperatively, the VAS score was 1.15±0.87; the AOFAS score was 89.45±6.24, and the results were excellent in 14 cases, good in 9 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 92%.ConclusionThe procedure of mini locking plate combined with Kirschner wire for comminuted Jones fracture has such advantages as convenient operation, more rigid fixation, high rate of fracture healing, and good functional recovery in foot.

      Release date:2018-05-02 02:41 Export PDF Favorites Scan
    • A finite element analysis of petal-shaped poly-axial locking plate fixation in treatment of Y-shaped patellar fracture

      Objective To establish the finite element model of Y-shaped patellar fracture fixed with titanium-alloy petal-shaped poly-axial locking plate and to implement the finite element mechanical analysis. Methods The three-dimensional model was created by software Mimics 19.0, Rhino 5.0, and 3-Matic 11.0. The finite element analysis was implemented by ANSYS Workbench 16.0 to calculate the Von-Mises stress and displacement. Before calculated, the upper and lower poles of the patella were constrained. The 2.0, 3.5, and 4.4 MPa compressive stresses were applied to the 1/3 patellofemoral joint surface of the lower, middle, and upper part of the patella respectively, and to simulated the force upon patella when knee flexion of 20, 45, and 90°. Results The number of nodes and elements of the finite element model obtained was 456 839 and 245 449, respectively. The max value of Von-Mises stress of all the three conditions simulated was 151.48 MPa under condition simulating the knee flexion of 90°, which was lower than the yield strength value of the titanium-alloy and patella. The max total displacement value was 0.092 8 mm under condition simulating knee flexion of 45°, which was acceptable according to clinical criterion. The stress concentrated around the non-vertical fracture line and near the area where the screws were sparse. Conclusion The titanium-alloy petal-shaped poly-axial locking plate have enough biomechanical stiffness to fix the Y-shaped patellar fracture, but the result need to be proved in future.

      Release date:2017-12-11 12:15 Export PDF Favorites Scan
    • Tunnel-type open reduction and internal fixation of rib fractures with titanium locking plate

      Objective To investigate the tunnel-type open reduction and internal fixation of rib fractures (ORIF) with titanium locking plate in traumatic rib fractures. Methods Clinical data of 10 patients with multiple rib fractures from June 2016 to January 2017 in the Sixth People’s Hospital Affiliated to Shanghai Jiaotong University were analyzed. There were 6 males and 4 males with an average age of 38.5±9.0 years (range, 30–63 years). All patients underwent emergency treatment, chest CT and ultrasound examination before they admitted to the hospital. According to rib fractures and injuries, patients were given the tunnel-type ORIF of rib fractures with titanium locking plates, the chest tube and negative suction drainage. The patients were followed up over three months. Results All patients were cured. There was no complication during follow-up. No wound infection and death occurred. Postoperative three-month follow-up showed that chest pain was significantly relieved without pulmonary atelectasis and pleural effusion or other complications. Conclusion Tunnel-type internal fixation of rib fractures with titanium locking plates is effective, which can quickly restore the stability and integrity of the thorax. Surgical procedure is simple and can get fast postoperative recovery to improve the patient's quality of life.

      Release date:2017-12-04 10:31 Export PDF Favorites Scan
    • Effectiveness of minimally invasive internal fixation with locking plates for mid-shaft clavicle fractures

      Objective To explore effectiveness of minimally invasive internal fixation with locking plates for mid-shaft clavicle fractures. Methods Between October 2022 and August 2023, 28 patients with mid-shaft clavicle fractures were treated by minimally invasive internal fixation with locking plates. There were 10 males and 18 females with a mean age of 46.2 years (range, 18-74 years). The fractures were caused by traffic accident in 16 patients, sports-related injury in 7 patients, and other injuries in 5 patients. According to Robinson classi?cation, the fractures were classified as type 2A1 in 1 case, type 2A2 in 6 cases, type 2B1 in 15 cases, and type 2B2 in 6 cases. The interval between fracture and operation ranged from 5 hours to 21 days (median, 1.0 days). The pain visual analogue scale (VAS) score was 8.1±1.6. The VAS score at 3 days after operation and the occurrence of complications after operation were recorded. During follow-up, X-ray films were re-examined to observe the healing of the fracture; the shoulder joint function was evaluated according to the Constant-Murley score at 6 months, and the length of the incision scar (total length of the distal and proximal incisions) was measured. ResultsAll operations were successfully completed without any subclavian vascular or nerve damage. All incisions healed by first intention. The VAS score was 1.2±0.7 at 3 days after operation, and there was a significant difference in VAS score between pre- and post-operation (t=8.704, P<0.001). At 1 week after operation, the patient’s shoulder was basically painless, and they resumed normal life. All patients were followed up 12-20 months (mean, 13.3 months). X-ray films showed that the bone callus began to form at 2-4 months after operation (mean, 2.7 months). There was no delayed healing or non healing of the fracture, and no loosening or fracture of the internal fixators during follow-up. At 6 months after operation, the mean total incision length was 1.5 cm (range, 1.1-1.8 cm); no patient complained of numbness or paresthesia on subclavicular region or anterior chest wall. The Constant-Murley score of shoulder joint function was 93-100 (mean, 97.6). Conclusion Minimally invasive internal fixation with locking plates is a good surgical method for treating mid-shaft clavicle fractures, with simple operation, minimal trauma, good postoperative results, and high satisfaction.

      Release date:2024-08-08 09:03 Export PDF Favorites Scan
    • BRIDGING FIXATION WITH LONG LOCKING PLATE FOR DISPLACED MIDSHAFT CLAVICULAR FRACTURES

      Objective To evaluate the effectiveness of bridging fixation with long locking plate for displaced midshaft clavicular fractures. Methods Between October 2010 and December 2011, 18 patients with displaced midshaft clavicular fracture were treated with reduction and bridging fixation with 9 or 10 holes locking plate. There were 17 males and 1 female with an average age of 47 years (range, 23-82 years). Fracture was caused by traffic accident in 6 cases, by falling in 10 cases, by crushing in 1 case, and by crashing object in 1 case. All fractures were closed and displaced or shortened (range, 2.1-3.4 cm; mean, 2.62 cm) with angulation deformity. According to Robinson classification criteria, 5 cases were rated as type 2B1 and 13 as type 2B2. The duration from injury to surgery was 5 hours to 19 days (mean, 5 days). The fracture healing time and complication were recorded; the effectiveness evaluation was performed with Constant-Murley score and satisfaction to appearance. Results No neurologic or vascular complication occurred with primary healing of incision. All patients were followed up 12-22 months (mean, 14.7 months). The fracture healing time was 9-14 weeks (mean, 11.4 weeks). During follow-up, no loosening or breakage of internal fixator was observed. The Constant-Murley score was 82-98 (mean, 92.4) at last follow-up; the satisfaction rate of appearance was 88.9% (16/18). Conclusion Bridging fixation with long locking plate is an effective method for treatment of displaced midshaft clavicular fractures. Preserved blood supply and stable angle are important to fracture healing.

      Release date:2016-08-31 04:07 Export PDF Favorites Scan
    • Development and clinical application of a new type of anatomical locking plate for sternoclavicular joint fracture and dislocation

      ObjectiveTo report a new type of anatomical locking plate for sternocalvicular joint, and investigate its effectiveness in treatment of sternoclavicular joint fracture and dislocation.MethodsA new type of anatomical locking plate for sternoclavicular joint was developed, which accorded with the anatomical features and biomechanical characteristics of Chinese sternoclavicular joint. By adopting the method of clinical randomized controlled study, 32 patients with the sternoclavicular joint fracture and dislocation who met the selection criteria between June 2008 and May 2015 were randomly divided into groups A and B (n=16), and the patients were treated with new anatomic locking plate and distal radial T locking plate internal fixation, respectively. There was no significant difference between 2 groups in gender, age, injured side, body mass index, cause of injury, type of injury, the time from injury to operation, and preoperative Rockwood grading score (P>0.05). The operation time, intraoperative blood loss, incision length, hospitalization time, and postoperative complications in 2 groups were recorded, and the effectiveness was evaluated by Rockwood grading score.ResultsThe operations of 2 groups completed successfully. The operation time, intraoperative blood loss, and hospitalization time in group A were significantly less than those in group B (P<0.05), but there was no significant difference in the incision length between 2 groups (t=0.672, P=0.507). All the patients were followed up 18-30 months (mean, 24 months). In group A, there were 1 case of sternoclavicular joint pain and 2 cases of wound infection; in group B, there were 1 case of sternoclavicular joint pain, 1 case of internal fixation loosening, and 1 case of sternoclavicular joint re-dislocation; there was no significant difference in complication incidence between 2 groups (P=1.000). The Rockwood grading scores at each time point after operation in 2 groups were significantly higher than those before operation. At 1 month after operation, the Rockwood grading score in group A was significantly higher than that in group B (t=2.270, P=0.031); but there was no significant difference in the Rockwood grading scores between the 2 groups at 6 months and at last follow-up (P>0.05). At last follow-up, according to the Rockwood scoring standard, the results of group A were excellent in 13 cases, good in 2 cases, poor in 1 case, the excellent and good rate was 93.75%; the results of group B were excellent in 11 cases, good in 4 cases, poor in 1 case, and the excellent and good rate was 93.75%; there was no significant difference between 2 groups (Z=–0.748, P=0.455).ConclusionThe new type of anatomic locking plate accords with the Chinese anatomical characteristics. It has the advantages of easy operative procedure, less surgical trauma, shorter operation time, less intraoperative blood loss, shorter hospitalization time, and it can achieve better results in the treatment of sternoclavicular joint fracture and dislocation.

      Release date:2018-03-07 04:35 Export PDF Favorites Scan