• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "lateral flow immunoassay" 2 results
    • Development of lateral flow immunoassay for SARS-CoV-2 antigen detection

      This article summarizes the development of lateral flow immunoassay for SARS-CoV-2 antigen detection. Lateral flow immunoassay is a rapid, low cost, and ease of use detection tool that has been widely applied in clinical and public health sectors. Since the outbreak of COVID-19, the technique has been adopted for rapid antigen diagnostic test of SARS-CoV-2, including commonly used colloidal gold nanoparticle-based lateral flow immunoassays as well as various fluorescence-based lateral flow immunoassays. With innovations in labelling methods, this detection technique has been in continuous development and is shifting from qualitative toward quantitative as well as gaining sensitivity.

      Release date:2023-05-09 03:11 Export PDF Favorites Scan
    • Application value of a novel magnetic particle-based chemiluminescence reagent for detecting cryptococcal capsular polysaccharide

      Objective To evaluate the performance of a novel magnetic particle-based chemiluminescence reagent for detecting cryptococcal capsular polysaccharide. Methods Serum and cerebrospinal fluid specimens were collected from patients with suspected cryptococcal infection at West China Hospital, Sichuan University between July 2022 and September 2023. All samples were simultaneously tested by chemiluminescence immunoassay (CLIA) and lateral flow immunoassay (LFA), and the results of the two methods were compared. Results A total of 357 patients with suspected cryptococcal infection were enrolled, including 247 serum samples and 110 cerebrospinal fluid samples. The novel magnetic particle-based CLIA reagent exhibited favorable clinical performance for cryptococcal infection detection. For serum and cerebrospinal fluid specimens, the sensitivity was 96.95% and 100.00%, respectively; the specificity was 99.14% and 100.00%, respectively. It showed high consistency with the LFA reagent (the kappa values were both greater than 0.98 for serum and cerebrospinal fluid samples). Moreover, the CLIA reagent enables quantitative measurement for clinical therapeutic monitoring. Conclusion The novel magnetic particle-based CLIA reagent possesses good diagnostic performance and can provide reliable and supportive laboratory evidence for clinical practice in both early diagnosis and therapeutic monitoring.

      Release date: Export PDF Favorites Scan
    1 pages Previous 1 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南