• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "laminoplasty" 23 results
    • EARLY OUTCOME OF DIFFERENT OPERATION METHODS IN TREATMENT OF MULTI-SEGMENTAL CERVICAL SPONDYLOTIC MYELOPATHY

      ObjectiveTo explore the early outcome of 3 different operation methods in the treatment of multi-segmental cervical spondylotic myelopathy (CSM). MethodsA retrospective analysis was made on the clinical data of 74 patients with multi-segmental CSM treated between January 2011 and March 2013. The patients were divided into 3 groups according to operation methods:open-door expansive laminoplasty by plate was used in 21 patients (group A), open-door expansive laminoplasty by anchor fixation in 28 patients (group B), and conventional unilaterally open-door expansive laminoplasty in 25 patients (group C). There was no significant difference in gender, age, disease druation, affected segments, preoperative Japanese Orthopaedic Association (JOA) score, and cervical curvature of C2-7 among 3 groups (P > 0.05). The peration time, intraoperative blood loss, and JOA score, cervical curvature, incidence of axial symptoms were recorded. ResultsThere was no significant difference of operation time and intraoperative blood loss between group A and group B (P > 0.05). All incisions healed by first intention. Cerebrospinal leak occurred in 2 cases (1 case of group B and 1 case of group C) and C5 nerve root palsy in 4 cases (2 cases of group A, 1 case of group B, and 1 case of group C); all the symptoms disappeared after symptomatic treatment. The patients were followed up 12-39 months (mean, 18.3 months). The position of internal fixation was good without loosening and pulling out in groups A and B. Reclosed open-door was observed in 2 cases of group C, which disappeared after the second surgery. The JOA scores were significantly increased at 6 months after operation when compared with preoperative scores in groups A, B, and C (P < 0.05). The cervical curvature of C2-7 at postoperation was significantly improved when compared with preoperative one in groups B and C (P < 0.05) except group A (P > 0.05). There were significant differences in JOA score and the cervical curvature among 3 groups at 6 months after operation (P < 0.05). The incidence of axial symptoms were 4.76% (1/21), 35.71% (10/28), and 72.00% (18/25) in groups A, B, and C respectively, showing significant differences (P < 0.017). ConclusionOpen-door expansive laminoplasty by plate has better early outcome than open-door expansive laminoplasty by anchor fixation and conventional unilaterally open-door expansive laminoplasty in the treatment of multi-segmental CSM.

      Release date: Export PDF Favorites Scan
    • COMPARATIVE STUDY ON MICROPLATE AND ANCHOR FIXATION IN OPEN-DOOR CERVICAL EXPANSIVE LAMINOPLASTY

      Objective To evaluate the effectiveness of microplate fixation in open-door cervical expansive laminoplasty (ELP) by comparing with anchor fixation. Methods Between January 2005 and October 2008, 35 patients with multi-segment cervical spondylotic myelopathy were treated. Of them, 15 patients underwent ELP by microplate fixation (microplate group) and 20 patients underwent ELP by anchor fixation (anchor group). In microplate group, there were 10 malesand 5 females with the age of (51.2 ± 11.5) years; the disease duration ranged from 6 to 60 months (mean, 14 months); and the preoperative Japanese Orthopoaedic Association (JOA) score was 7.7 ± 2.5. In anchor group, there were 13 males and 7 females with the age of (50.7 ± 10.8) years; the disease duration ranged from 3 to 58 months (mean, 17 months); and the preoperative JOA score was 7.8 ± 2.9. There was no significant difference in the general data, such as gender, age, and JOA score between 2 groups (P gt; 0.05). Results All incisions healed by first intention. Thirty-five cases were followed up 24-68 months (mean, 32 months). The operation time was (113 ± 24) minutes in anchor group and (111 ± 27) minutes in microplate group, showing no significant difference (t=0.231 3, P=0.818 5). The rate of spinal canal expansion in microplate group (60% ± 24%) was significantly higher than that in anchor group (40% ± 18%) (t=2.820, P=0.008). The JOA scores of 2 groups at 3 months and 24 months after operation were significantly higher than the preoperative scores (P lt; 0.01). There was no significant difference in JOA score between 2 groups at 3 months after operation (t=1.620 5, P=0.114 6), but the JOA score of microplate group was significantly higher than that of anchor group at 24 months after operation (t=3.454 3, P=0.001 5). X-ray film, MRI, and CT scan at 3-6 months after operation displayed that door spindle reached bony fusion. There was no occurrence of ‘‘re-close of door’’ in 2 groups. The rate of compl ication in microplate group (13.3%, 2/15) was significantly lower than that in anchor group (25.0%, 5/20) (χ2=7.160 0, P=0.008 6). Conclusion ELP by microplate fixation can achieve the stabil ity quickly after operation, which can help patients to do functional exercises early, and has satisfactory effectiveness and less complications.

      Release date:2016-08-31 05:44 Export PDF Favorites Scan
    • The application of ultrasonic bone curette in laminoplasty of spinal canal after resection of intraspinal tumors

      Objective To explore the practicability and safety of ultrasonic bone curette in the laminoplasty of spinal canal after resection of intraspinal tumors. Methods The clinical data of 17 patients with thoracolumbar intraspinal tumors treated with ultrasonic bone curette after resection of intraspinal tumors between December 2015 and April 2017 were retrospectively analyzed. All patients were male, aged 42-73 years with an average of 57.4 years. The disease duration was 2-47 months with an average of 21.1 months. Among them, there were 4 cases of thoracic intrathoracic tumors (T10 in 1, T12 in 3) and 13 cases of lumbar intrathoracic tumors (L1 in 5, L2 in 4, L3 in 2, and L4 in 2). Postoperative pathological diagnosis showed that 8 cases were schwannoma, 4 cases were meningioma, 2 cases were neurofibroma, 2 cases were dermoid cyst, and 1 case was ependymoma. Spinal nerve function was evaluated preoperatively according to Frankel classification criteria, with 2 cases of grade B, 7 cases of grade C, and 8 cases of grade D. During the operation, the time of single segmental vertebral canal posterior wall incision, the overall operation time, intraoperative blood loss, intraoperative dural injury, and cerebrospinal fluid leakage, spinal cord and nerve root injury were recorded. At 3-6 months after operation, the tumor and bone healing were observed according to MRI and CT three-dimensional reconstruction, and the spinal nerve function was evaluated by Frankel classification. Results The time of ultrasonic osteotomy for the posterior wall of a single segmental vertebral canal was 3.4-5.7 minutes, with an average of 4.1 minutes. The overall operation time was 135-182 minutes, with an average of 157.3 minutes. The intraoperative blood loss was 300-500 mL, with an average of 342.6 mL. There was no accidental dural injury, and cerebrospinal fluid leakage, nerve root injury, or spinal cord injury. The incision healed by first intention after operation. All the 17 patients were followed up 9-18 months, with an average of 12.7 months. MRI examination showed no tumor recurrence, and CT three-dimensional reconstruction showed good bone healing in all patients. During the follow-up, there was no loosening or rupture of the internal fixator and there was no re-compression of the spinal cord. At last follow-up, according to Frankel classification, there were 1 case as grade B, 5 cases as grade C, 7 cases as grade D, and 4 cases as grade E. Conclusion The application of ultrasonic bone curette in laminoplasty of spinal canal after resection of intraspinal tumors can preserve the integrity of the bone ligament structure of posterior column, maintain the volume of vertebral canal, and has high safety, practicability, and good postoperative effectiveness.

      Release date:2019-01-03 04:07 Export PDF Favorites Scan
    • An Applied Anatomy Research of Digital-CT-based Unilateral Open-door Cervical Expansive Laminoplasty of C7

      ObjectiveTo explore early clinical effects of Centerpiece-based unilateral open-door cervical expansive laminoplasty plus centerpiece titanium minitype plate fixation, to research the data of the best slotting in the CT-based open-door cervical operation and to provide the reference for accurate operation. MethodsA retrospective analysis of the patients who had received Centerpiece-based unilateral open-door cervical expansive laminoplasty plus centerpiece titanium plate fixation from West China Hospital of Sichuan University from February 2013 to November 2013 were performed. The neurological function assessment results (JOA score), cervical curvature indexhave, Pavlov value, spinal canal cross-sectional area and different position, angle and depth of C7 lamina slotting data of all patients before and after the operation were all analyzed and compared. ResultsA total of 58 patients were included. The postoperative JOA score was significantly higher than that of the preoperative (9.4±2.9 vs. 14.7±2.6, t=11.417, P=0.000). The sagittal diameter of vertebral canal (21.3±2.1 mm vs. 9.7±2.1 mm, t=27.737, P=0.000), Pavlov value (0.92±0.13 vs. 0.44±0.12, t=30.621, P=0.000), and spinal canal cross-sectional area (276±37 mm2 vs. 129±25 mm2, t=32.104, P=0.000) at the end of the last follow-up were significantly greater than those of preoperative. When comparing the last follow-up with preoperative, cervical curvature index showed significant difference (11.2±11.5 vs. 9.3±11.7, t=-1.713, P=0.000). Significant differences were found in the comparison of the ideal position and angle of the open door of the C7 lamina and the angle and position of the operation (all P values >0.05); when comparing the position and angle of the ideal position and angle of the C7 lamina hinge with that of the actual operation, no significant differences were found (all P values >0.05); but when comparing the ideal depth with the actual depth of the operation, a significant difference was found (P<0.05). ConclusionCenterpiece micro plate used in posterior cervical expansive open-door laminoplasty forming operation of laminectomy fixed screw loosening and plate breakage, can effectively maintain the lamina in the open state, and prevent it to be closed. The patients have good recovery of nerve function after operation and the clinical efficacy is good.

      Release date: Export PDF Favorites Scan
    • EFFECT OF PENETRATION OF MINI-PLATE LATERAL MASS SCREWS INTO FACET JOINT ON AXIAL SYMPTOMS IN CERVICAL LAMINOPLASTY

      Objective To investigate the effect of the penetration of mini-plate mass screws into facet joint on axial symptoms in cervical laminoplasty. Methods A retrospective analysis was made on the clinical data of 52 patients who underwent unilateral open-door cervical expansive laminoplasty fixed with Centerpiece mini-plate between September 2009 and December 2011. There were 42 males and 10 females, with a mean age of 61.2 years (range, 34-83 years). Seventeen patients exhibited simple degeneration cervical canal stenosis, 25 patients had multilevel cervical disc protrusion, and 10 patients had ossification of posterior longitudinal ligaments. Disease duration ranged 1-120 months (median, 11 months). The Japanese Orthopedic Association (JOA) score was used to assess neurological function, and JOA recovery rates were calculated. The visual analogue score (VAS) and the neck disability index (NDI) were used to evaluate the axial pain and neck daily activities. The axial symptoms and other complications were recorded. The cervical canal diameter, cervical curvature, cervical canal cross area, and open angle were measured according to the X-ray films, CT scans, and MRI scans. The postoperative CT three dimensional (3-D) reconstruction images were used to identify whether the screws penetrated into the facet joints. All the patients were divided into 3 groups according to involved facet joints: no joint penetrating group (no penetrated facet joint), oligo-joint penetrating group (one or two penetrated facet joints), and multi-joint penetrating group (three or more penetrated facet joints). Results Five patients suffered from C5 nerve palsy, and 2 patients had cerebrospinal fluid leakage. The follow-up time ranged 3-35 months (mean, 15.7 months). At the final follow-up, the JOA scores, NDI, cervical canal diameter, and cervical canal cross area were significantly improved when compared with preoperative ones (P lt; 0.05). At 1 week after operation, CT 3-D reconstruction showed that 16 patients had no penetrated facet joint, 23 patients had one or two penetrated facet joints, and 13 patients had three or more penetrated facet joints. There was no significant difference in age, gender, disease duration, operation time, intraoperative blood loss, and follow-up time among 3 groups (P gt; 0.05). And at the final follow-up, there was no significant difference in JOA score, VAS score, cervical curvature, cervical canal diameter, cervical canal cross area, the JOA recovery rates, and lamiae open angle among 3 groups (P gt; 0.05). The NDI of the multi-joint penetrated group was significantly higher than that of other 2 groups (P lt; 0.05). Axial pain occurred in 1 case of no penetrating group, in 4 cases of oligo-joint penetrating group, and in 5 cases of multi-joint penetrating group, showing no significant difference among 3 groups (χ2=4.881, P=0.087). Conclusion The penetrations of lateral mass screws into articular surface of facet joint may contribute to the axial symptoms after cervical laminoplasty. The risk of axial symptom raises accompany with increased penetrated facet joints.

      Release date:2016-08-31 04:05 Export PDF Favorites Scan
    • EFFECT OF SPINAL DURAL RELEASE ON TREATMENT OF MULTI-SEGMENTAL CERVICAL MYELOPATHY WITH OSSIFICATION OF POSTERIOR LONGITUDINAL LIGAMENT BY CERVICAL LAMINOPLASTY

      ObjectiveTo explore the effect of spinal dural release on the effectiveness of expansive cervical laminoplasty for treating multi-segmental cervical myelopathy with ossification of posterior longitudinal ligament. MethodsA retrospective analysis was made on the clinical data of 32 patients with multi-segmental cervical myelopathy with cervical ossification of posterior longitudinal ligament who underwent expansive cervical laminoplasty and spinal dural release between February 2011 and October 2013 (group A); and 36 patients undergoing simple expansive cervical laminoplasty between January 2010 and January 2011 served as controls (group B). There was no significant difference in gender, age, disease duration, affected segments, combined internal disease, preoperative cervical curvature, Japanese Orthopaedic Association (JOA) score, and visual analogue scale (VAS) score between 2 groups (P>0.05). Postoperative JOA score and improvement rate, VAS score, posterior displacement of the spinal cord, and the change of cervical curvature were compared between 2 groups. ResultsSpinal dural tear occurred in 3 cases (2 cases in group A and 1 case in group B) during operation. Cerebrospinal fluid leakage occurred in 3 cases (2 cases in group A and 1 case in group B) after operation. The patients were followed up 12-46 months (mean, 18.7 months). At last follow-up, the JOA score and VAS score were significantly improved in 2 groups when compared with preoperative scores (P<0.05). JOA score and improvement rate of group A were significantly higher than those of group B (P<0.05), but VAS score of group A was significantly lower than that of group B (P<0.05). At last follow-up, no significant difference in cervical curvature was found between 2 groups (P>0.05); posterior displacement of the spinal cord of group A was significantly larger than that of group B (P<0.05). No reclosed open-door was observed during follow-up. ConclusionFor patients with multi-segmental cervical myelopathy with ossification of posterior longitudinal ligament, full spinal dural release during expansive cervical laminoplasty can increase the posterior displacement of spinal cord, and significantly improve the effectiveness.

      Release date: Export PDF Favorites Scan
    • EFFECTIVENESS ANALYSIS OF Vertex ROD-SCREW SYSTEM IN CERVICAL EXPANSIVE OPEN-DOOR LAMINOPLASTY

      Objective To evaluate the cl inical appl ication value and short-term results of Vertex rod-screw system in cervical expansive open-door laminoplasty. Methods Between February 2008 and January 2010, 28 patients underwent Vertex rod-screw system fixation in cervical expansive open-door laminoplasty, including 15 cases of cervical spondylotic myelopathy, 5 cases of ossification of posterior longitudinal l igament,and 8 cases of cervical spondylosis with spinal stenosis. There were 16 males and 12 females, aged 42-77 years (mean, 61.3 years). The disease duration was 2 months to 11 years. The decompression range of cervical spine was from C3 to C7. The operation time, blood loss, Japanese Orthopedic Association (JOA) scores, and incidence of axial symptom were recorded. Pre- and postoperative curvature angles were demonstrated by the cross angle between posterior vertebral body margins of C2 and C7 on cervical X-ray films. The angle of the opened laminae was measured on CT scan at last follow-up. Results The operation time was (142.5 ± 22.8) minutes, and the blood loss was (288.2 ± 55.1) mL. All incisions healed by first intention. All patients were followed up 14-25 months (mean, 22 months). CT showed that no reclosed open-laminae or loosening and breakage of rod-screw system occurred at 1 week and 1 year after operation. The axial bony fusion rate was 89.3% (25/28). The improvement rate of JOA scores at 1 week after operation (29.5% ± 15.0%) was significantly smaller than that at 1 year after operation (64.9% ± 28.1%) (t=0.810, P=0.000). No case presented with C5 nerve root palsy. The cervical curvature angle was (24.29 ± 5.04)° before operation, was (23.89 ± 3.57)° at 1 week, and was (23.41 ± 3.35)° at 1 year after operation, showing no significant difference between pre- and postoperative angles (P gt;0.05). The angle of the opened laminae was (27.90 ± 4.74)° at 1 week after operation, and was (28.07 ± 4.21)° at 1 year after operation, showing no significant difference (P gt; 0.05). Conclusion Vertex rod-screw system in cervical expansive opendoor laminoplasty is effective in preventing reclosed open-laminae, which can reduce the loss of cervical curvature angle.

      Release date:2016-08-31 05:42 Export PDF Favorites Scan
    • Effect of modified lateral mass screws implantation strategy on axial symptoms in cervical expansive open-door laminoplasty

      ObjectiveTo investigate the effect of modified lateral mass screws implantation strategy on axial symptoms in cervical expansive open-door laminoplasty. MethodsA clinical data of 166 patients, who underwent cervical expansive open-door laminoplasty between August 2011 and July 2016 and met the selection criteria, was retrospective analyzed. Among them, 81 patients were admitted before August 2014 using the traditional mini-plate placement and lateral mass screws implantation strategy (control group), and 85 patients were admitted after August 2014 using modified lateral mass screws implantation strategy (modified group). There was no significant difference in the gender composition, age, clinical diagnosis, disease duration, diseased segment, and preoperative Japanese Orthopaedic Association (JOA) score, pain visual analogue scale (VAS) score, Neck Disability Index (NDI), cervical curvature and range of motion, spinal canal diameter and cross-sectional areas, and Pavlov’s value between the two groups (P>0.05). The operation time, intraoperative blood loss, the number of facet joints penetrated by lateral mass screws, effectiveness evaluation indexes (JOA score and improvement rate, VAS score, NDI), imaging evaluation indexes (cervical curvature and range of motion, spinal canal diameter and cross-sectional areas, Pavlov’s value, and lamina open angle), and complications were recorded and compared between the two groups.ResultsThe modified group had shorter operation time and lower intraoperative blood loss than the control group (P<0.05). There were 121 (29.9%, 121/405) and 10 (2.4%, 10/417) facet joints penetrated by lateral mass screws in control and modified groups, respectively; and the difference in incidence was significant (χ2=115.797, P=0.000). Eighteen patients in control group had 3 or more facet joints penetrated while no patients in modified group suffered 3 or more facet joint penetrated. The difference between the two groups was significant (P=0.000). All patients were followed up, the follow-up time was (28.7±4.9) months in modified group and (42.4±10.7) months in control group, showing significant difference (t=10.718, P=0.000). The JOA score, VAS score, and NDI at last follow-up of the two groups were significantly improved compared with preoperative (P<0.05); there was no significant difference in JOA score and improvement rate and VAS score between the two groups (P>0.05), but the NDI was significantly lower in modified group than in control group (P<0.05). There were significant differences in cervical curvature and range of motion, spinal canal diameter, Pavlov’s value, and cross-sectional areas at last follow-up when compared with those before operation in both groups (P<0.05). There was no significant difference in the above indicators and lamina open angle between the two groups (P>0.05). The modified group has a relative lower axial symptom rate (23/85, 27.1%) than the control group (27/81, 33.3%), but the difference was not significant (Z=?1.446, P=0.148). There was no significant differences between the two groups in the incidences of C5 nerve root palsy, cerebrospinal fluid leakage, wound infection, and lung or urinary tract infection (P>0.05). ConclusionIn the cervical expansive open-door laminoplasty, the modified lateral mass screws implantation strategy can effectively reduce the risk of lateral mass screw penetrated to the cervical facet joints, and thus has a positive significance in avoiding the axial symptoms caused by facet joint destruction.

      Release date:2021-04-27 09:12 Export PDF Favorites Scan
    • Correlation analysis of preoperative T1 slope in MRI and physiological curvature loss after expansive open-door laminoplasty

      Objective To investigate whether preoperative T1 slope (T1S) in MRI can predict the changes of cervical curvature after expansive open-door laminoplasty (EOLP) in patients with cervical spondylotic myelopathy, so as to make up for the shortcomings of difficult measurement in X-ray film. Methods The clinical data of 36 patients with cervical spondylotic myelopathy who underwent EOLP were retrospectively analysed. There were 21 males and 15 females with an average age of 55.8 years (range, 37-73 years) and an average follow-up time of 14.3 months (range, 12-24 months). The preoperative X-ray films at dynamic position, CT, and MRI of cervical spine before operation, and the anteroposterior and lateral X-ray films at last follow-up were taken out to measure the following sagittal parameters. The parameters included C2-C7 Cobb angle and C2-C7 sagittal vertical axis (C2-C7 SVA) in all patients before operation and at last follow-up; preoperative T1S were measured in MRI, and the patients were divided into larger T1S group (T1S>19°, group A) and small T1S group (T1S≤19°, group B) according to the median of T1S, and the preoperative T1S, C2-C7 Cobb angle, C2-C7 SVA, and the C2-C7 Cobb angle and C2-C7 SVA at last follow-up, difference in axial distance (the difference of C2-C7 SVA before and after operation), postoperative curvature loss (the difference of C2-C7 Cobb angle before and after operation), the number of patients whose curvature loss was more than 5° after operation, and the number of patients whose kyphosis changed (C2-C7 Cobb angle was less than 0° after operation). Results The C2-C7 Cobb angle at last follow-up was significantly decreased when compared with preoperative value (t=8.000, P=0.000), but there was no significant difference in C2-C7 SVA between pre- and post-operation (t=–1.842, P=0.074). The preoperative T1S was (19.69±3.39)°; there were 17 cases in group A and 19 cases in group B with no significant difference in gender and age between 2 groups (P>0.05). The preoperative C2-C7 Cobb angle in group B was significantly lower than that in group A (t=–2.150, P=0.039), while there was no significant difference in preoperative C2-C7 SVA between 2 groups (t=0.206, P=0.838). At last follow-up, except for the curvature loss after operation in group B was significantly lower than that in group A (t=–2.723, P=0.010), there was no significant difference in the other indicators between 2 groups (P>0.05). Conclusion Preoperative larger T1S (T1S>19°) in MRI had a larger preoperative lordosis angle, but more postoperative physiological curvature was lost; preoperative T1S in MRI can not predict postoperative curvature loss, but preoperative larger T1S may be more prone to kyphosis.

      Release date:2018-01-09 11:23 Export PDF Favorites Scan
    • CANAL LAMINOPLASTY WITH TITANIUM MINIPLATE REIMPLANTATION OF VERTEBRAL LAMINA

      Objective To evaluate the reliability and the advantageof canal laminoplasty with laminoplasty over laminectomy for treatment of lumbar spinal stenosis.Methods From June 2000 to September 2004, the titanium miniplate fixation technique was applied to re-implantation of the vertebral lamina in the lumbar spine. The vertebral lamina was made with a specially made osteotome and a special technique in 18 patients with lumbar spinal stenosis. Results The patients were followed up for 1 yr and 8 mon on average (range, 3 mon4 yr and 3 mon) and were observed to have a bony fusion of the re-implanted lamina 3-9 months postoperatively. There was no nonunion, displacement of the re-implanted lamina, overgrowth of the anterior bone edge of osteotomy, recompression of the nerves or instability of the lumbar spine. Conclusion The result demonstrates that canal laminoplasty with the titanium miniplate re-implantation of the vertebral lamina in lumbar spine can restore the normal anatomy, keep stability of the spine, and avoid adhesion and scar in the canal.

      Release date:2016-09-01 09:25 Export PDF Favorites Scan
    3 pages Previous 1 2 3 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南