ObjectivesTo systematically review the efficacy of absorbable barbed suture versus traditional absorbable suture in total knee arthroplasty (TKA).MethodsPubMed, EMbase, The Cochrane Library, CBM, WanFang Data, CNKI and VIP databases were electronically searched to collect clinical trials of absorbable barbed suture versus traditional absorbable suture in TKA from inception to November, 2017. Two reviewers independently screened literature, extracted data and assessed risk of bias of included studies, then, meta-analysis was performed by using RevMan 5.3 software.ResultsA total of 6 randomized controlled trials (RCTs) and 5 cohort studies were included, involving 2 008 patients. Meta-analysis showed that the joint capsule suture time of the absorbable barbed suture group [MD=–4.31, 95% CI (–4.72, –3.90), P<0.000 01], the incidence of acupuncture injury during suture [OR=0.14, 95% CI (0.03, 0.61),P=0.009], and incision complication rate [OR=0.56, 95% CI (0.36, 0.88), P=0.01] were significantly lower than the traditional absorbable suture group, but the incidence of suture fracture [OR=23.03, 95% CI (3.08, 172.09),P=0.002] was higher, yet the difference was statistically significant. There were no significant differences in the incidence of superficial infection, deep infection, aseptic redness, incision dehiscence and KSS score at 3 months after operation (P>0.05).ConclusionsAvailable evidence suggests that the use of absorbable barbed sutures to close the TKA surgical incision shortens the time to suture the joint capsule, reduces the incidence of acupuncture injury as well as the overall incidence of incision complications without increasing superficial infection, deep infection, and sterility. The incidence of redness and incision splitting has no significant effects on joint function at 3 months after surgery, however the incidence of suture fracture is higher. Due to limited quality and quantity of the included studies, the above conclusions are required to be verified by more high-quality studies.
Objective To compare the cl inical results between high-flexion and standard cruciate-stabling prostheses in total knee arthroplasty (TKA) by using the 36-item short form health survey (SF-36). Methods Between August 2007 and January 2009, 98 patients (106 knees) underwent TKA with standard cruciate-stabl ing prostheses (standard group), and 46 patients (50 knees) underwent TKA with high-flexion prostheses (high-flexion group). In standard group, there were30 males (32 knees) and 68 females (74 knees) with an age of (70.0 ± 3.5) years, including 78 cases (82 knees) of osteoarthritis (OA) and 20 cases (24 knees) of rheumatoid arthritis (RA) with a disease duration of (14.5 ± 3.3) years; the Hospital for Special Surgery Scoring System (HSS) and the range of motion (ROM) were 56.1 ± 21.6 and (89.0 ± 16.1)°, respectively. In high-flexion group, there were 8 males (10 knees) and 38 females (40 knees) with an age of (68.6 ± 8.9) years, including 44 cases (47 knees) of OA and 2 cases (3 knees) of RA with a disease duration of (13.9 ± 4.1) years; the HSS and ROM were 58.9 ± 25.3 and (91.0 ± 19.3)°, respectively. There was no significant difference in the general data (P gt; 0.05) between 2 groups, so the cl inical data of 2 groups had comparabil ity. Results In standard group, poor wound heal ing and persistent headache caused by cerebrospinal fluid leakage occurred in 1 case, respectively. In high-flexion group, transient common peroneal nerve palsy occurred in 1 case. There was significant difference (P lt; 0.05) in the hospital ization expense between standard group [ (39 000 ± 6 000)] and highflexion goup [ (52 000 ± 8 000)]. The follow-up time was 12-26 months (18 months on average) in standard group (91 cases, 98 knees) and 11-19 months (13 months on average) in high-flexion group (44 cases, 47 knees). The SF-36 showed significant difference in role-physical score (P lt; 0.05), but no significant difference in other 7 indices scores (P gt; 0.05). At the final follow-up, the ROM was (129.1 ± 19.2)° in high-flexion group and (123.6 ± 16.7)° in standard group; showing significant difference (P lt; 0.05). The HSS was 91.2 ± 17.6 in high-flexion group and 92.5 ± 14.5 in standard group; showing no significant difference (P gt; 0.05). Conclusion After TKA, the ROM in high-flexion group is superior to that in standard group, but there is no obvious advantages in terms of the HSS and SF- 36 outcomes.
Objective To make a retrospective analysis on an early clinical outcome of total knee arthroplasty (TKA) for the knees with different degrees of flexion-contracture deformities. Methods Ninety-seven knees of 65 patients undergoing total knee arthroplasty with the Scorpio posterior-stabilized knee prosthesis from January 2000 to December 2003 were reviewed, including 51 osteoarthritis patients (74 knees) and 14 rheumatoid arthritis patients (23 knees). Thirtythree patients underwent unilateral TKA, and 32 patients underwent bilateral TKA. The average range of motion (ROM) before operation was 82.8°(range, 5-140°).According to the preoperative flexion-contracture degrees of the knees, these patients were divided into 2 groups, group A and group B. Group A consisted of the patients with flexioncontracture less than 20° (range, 0-15°), and group B consisted of the patients with flexion-contracture not less than 20° (range, 20-60°). In group A, the average flexion-contracture degree, ROM, KSS (knee society score), and function score were 10.7±8.0°, 104.6±20.0°, 29.1±18.0, and 32.6±20.7, respectively. But the corresponding data were much worse ingroup B than in group A, which were 28.2±7.8°, 60.8±26.6°, 12.1±13.2, and 26.8±18.1. All the operations were primary total knee arthroplasty, and they were performed by the same group of surgeons. The time for the prosthesis installed lasted for 25.6 minutes, and the average tourniquet time was 34.7 minutes. Three or four days after operation, the patients began the continuous passive motion (CPM) and active functional exercise of the knee.Results The patients were followed up for an average of 2 years and 7 months(range, 8 mon-3.5 yr). During the follow-up period, the average flexion-contracture degree, ROM, KSS, and function score in group A were 0.4±2.1°, 108.6±19.0°, 82.1±13.8, and 72.3±29.1, respectively; and the corresponding data in group B were 1.3±3.2°, 986±16.4°, 75.9±8.2, and 81.4±26.9, respectively. There was no significant difference between the 2 groups. No revision or deep infection was found. Conclusion The curative effect is mainly determined by the surgeon’s good operational skills, rich clinical experience, and familiarity with the prosthesis, and it is not influenced by severity of the knee flexioncontracture deformity. The knee ROM after TKA, which has a “toward middle ROM”phenomenon, is influenced by many clinical factors. It is very important for the patientto perform a functional exercise of the knee as early as possible after operation.
Objective To conduct a systematic bibliometric analysis of recent research on robot-assisted orthopedic surgery, in order to reveal the research trends, hotspots, main contributors, and future development directions in this field. Methods On August 27, 2024, WoSCC (Web of Science Core Collection Database) was searched and relevant literature on robot-assisted orthopedic surgery from 2003 to 2023 was included. Excel 2016, VOSviewer (version 1.6.10), and CiteSpace (version 6.2.R6) were used for data collection and analysis. Results The total citation frequency of 1718 retrieved literature was 28978 times, with an average citation frequency of 16.87 times per article. The total citation frequency of articles in 2019 was the highest (4330 times), and the publication volume in 2023 was the highest (315 articles). Among the top 5 countries in terms of publication volume, the United States had the highest publication volume and total citation frequency, while China ranked second in terms of publication volume, but had the lowest average citation frequency per article. Analysis of cooperation between countries showed that the United States, China, Germany, and other countries had the most cooperation. Babar Kayani’s articles were cited the most frequently. Among the top 10 institutions in terms of publication volume, the Hospital for Special Surgery (United States) had the highest publication volume, the Pennsylvania State System of Higher Education (United States) had the highest total citation frequency for publications, and the average citation frequency of each article published by the University of Pittsburgh (United States) was the highest. The dynamic evolution of research hotspots suggested that early research mainly focused on the combination of traditional surgical techniques and navigation, while in recent years, research had mainly focused on computer-aided surgery, augmented reality, and medical robotics technology. Conclusions In recent years, significant progress has been made in the research of robot-assisted orthopedic surgery, with the United States taking a leading position in this field and having extensive global cooperation. Research hotspots show that with the continuous development of computer-aided surgery, augmented reality, and robotics technology, the field of orthopedic surgery is evolving towards more precise, individualized, and minimally invasive directions.
ObjectiveTo compare the effectiveness of unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) in the treatment of severe medial compartment osteoarthritis (OA).MethodsA clinical data of 69 patients (69 knees), who underwent joint replacement due to severe medial compartment OA between February 2015 and September 2018 and met the selection criteria, was retrospectively analyzed. Among them, 38 cases were treated with UKA (UKA group) and 31 cases with TKA (TKA group). There was no significant difference in gender, age, body mass index, course of disease, lesion side, and preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) score, Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score, Feller score, range of motion of knee, physiological and psychological scores of short-form 12 health survey scale (SF-12) between the two groups (P>0.05). The femorotibial angle (FTA) of TKA group was bigger than that of UKA group, and hip-knee-ankle angle (HKA) was smaller, showing significant differences (P<0.05). The operative time, incision length, blood loss, time for flexion 90°, ambulation time, hospital stay, and incidence of deep venous thrombosis of lower extremity were recorded and compared between the two groups. The VAS score, HSS score, WOMAC score, Feller score, range of motion, and physiological and psychological scores of SF-12 were used to evaluate patients’ quality of life. FTA, HKA, and prosthesis looseness were observed by X-ray films. Kaplan-Merier survival analysis was used to evaluate the survival rate of prosthesis.ResultsAll operations were successfully completed in both groups. Compared with TKA group, UKA group had shorter incision length, longer operative time, and less blood loss (P<0.05). There was no significant difference in time for flexion 90°, ambulation time, hospital stay, and the incidence of deep venous thrombosis of lower extremity between the two groups (P>0.05). The incisions in both groups healed by first intention. During follow-up, 3 patients in the UKA group and 1 patient in the TKA group developed mild anterior knee pain. Patients were followed up (30.7±9.6) months in the UKA group and (34.9±8.7) months in the TKA group, and the difference was not significant (t=–1.832, P=0.071). At last follow-up, there were significant differences in the HSS score, Feller score, WOMAC score, range of motion, VAS score, and physiological and psychological scores of SF-12 between pre- and post-operation (P<0.05). The range of motion in the UKA group was bigger than that in the TKA group (Z=–2.666, P=0.008), and there was no significant difference in the other indexes between the two groups (P>0.05). X-ray films showed that the alignment of the two groups recovered well, and the FTA and HKA of the two groups were improved at 1 week after operation (P<0.05). No radiolucency was found around the prosthesis during follow-up, no prosthesis loosening and meniscal bearing dislocation occurred. The survival rates of the prostheses in the two groups were 100%.ConclusionFor severe medial compartment OA, the early survival rates of the two prostheses are similar, but UKA has less traumatic, can preserve the normal structure of the knee, and the range of motion of the knee after operation is significantly better than TKA.
The clinical performance and failure issues are significantly influenced by prosthetic malposition in unicompartmental knee arthroplasty (UKA). Uncertainty exists about the impact of the prosthetic joint line height in UKA on tibial insert wear. In this study, we combined the UKA musculoskeletal multibody dynamics model, finite element model and wear model to investigate the effects of seven joint line height cases of fixed UKA implant on postoperative insert contact mechanics, cumulative sliding distance, linear wear depth and volumetric wear. As the elevation of the joint line height in UKA, the medial contact force and the joint anterior-posterior translation during swing phase were increased, and further the maximum von Mises stress, contact stress, linear wear depth, cumulative sliding distance, and the volumetric wear also were increased. Furthermore, the wear area of the insert gradually shifted from the middle region to the rear. Compared to 0 mm joint line height, the maximum linear wear depth and volumetric wear were decreased by 7.9% and 6.8% at –2 mm joint line height, and by 23.7% and 20.6% at –6 mm joint line height, the maximum linear wear depth and volumetric wear increased by 10.7% and 5.9% at +2 mm joint line height, and by 24.1% and 35.7% at +6 mm joint line height, respectively. UKA prosthetic joint line installation errors can significantly affect the wear life of the polyethylene inserted articular surfaces. Therefore, it is conservatively recommended that clinicians limit intraoperative UKA joint line height errors to –2?+2 mm.
Objective To analyse the results of posterior cruciate l igament-retained mobile-bearing total knee arthroplasty (TKA) in treatment of rheumatoid arthritis (RA) and to solve the problems often encountered during surgery. Methods From February 1999 to August 2005, the cl inical data from 73 patients with RA undergoing TKA were analysed retrospectively. In 73 patients, 38 patients were treated with posterior cruciate l igament-retained mobile-bearing prosthesis (group A), while 35 patients were treated with posterior stabil ized fixed-bearing prosthesis (group B). Another 70 patients with osteoarthritis (OA) treated with an posterior cruciate l igament-retained mobile-bearing prosthesis served as controls (group C). In group A, there were 8 males and 30 females with an average age of 56.5 years and an average diseasecourse of 16.8 years. In group B, there were 6 males and 29 females with an average age of 57.3 years and an average disease course of 17.1 years. In group C, there were 37 males and 33 females with an average age of 65.4 years and an average disease course of 10.8 years. There was no significant difference (P gt; 0.05) in general data between groups A and B, but there were significant differences (P lt; 0.05) when compared with group C. Results In groups A and B, 2 cases (5.3%) and 1 case (2.9%) had poor heal ing of incision, respectively; in group C, all cases had good heal ing of incision. There were significant differences in heal ing rate of incision between groups A, B and group C (P lt; 0.05). All patients were followed up 7.6 years on average (range, 3.5-10.5 years). Deep infection occurred in 1 case respectively in 3 groups, showing no significant difference (P gt; 0.05). Posterior instabil ity occurred in 1 case (2.6%) 5 years after operation in group A and 2 cases (2.9%) 9 years after operation in group C, and no posterior instabil ity occurred in group B; showing significant differences between groups A, C and group B (P lt; 0.05). There were significant differences (P lt; 0.05) in knee score, Feller patellar score, and anterior knee pain score between pre- and postoperative values among groups A, B, and C. There were significant differences (P lt; 0.05) in the function scores between pre- and post-operative values in 3 groups, between groups A, B and group C pre- and post-operatively. Conclusion Posterior cruciate l igament-retained mobile-bearing TKA can yield satisfactory cl inical results in treatment of RA at intermediate-term followup. This mobile-bearing prosthesis has a low prevalence of posterior instabil ity and a good outcome for anterior knee function without patellar resurfacing.
ObjectiveA prospective randomized controlled study was conducted to investigate the early postoperative analgesic effectiveness of using liposomal bupivacaine (LB) for local infiltration anesthesia (LIA) in unicompartmental knee arthroplasty (UKA). Methods Between January 2024 and July 2024, a total of 80 patients with knee osteoarthritis (KOA) who met the selection criteria were enrolled in the study. Patients were randomly assigned to either the LB group or the “cocktail” group in a 1∶1 ratio using a random number table, with 40 patients in each group. Baseline characteristics, including gender, age, body mass index, operated side, Kellgren-Lawrence grade, and preoperative American Society of Anesthesiologists (ASA) classification, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and knee joint range of motion, showed no significant difference between the two groups (P>0.05). Both groups received LIA and comprehensive pain management. The surgical duration, incision length, pain-related indicators [resting and activity visual analogue scale (VAS) scores, total dosage of oral morphine, WOMAC scores], knee joint range of motion, first ambulation time after operation, length of hospital stay, and postoperative adverse events. ResultsThere was no significant difference between the two groups in surgical duration, incision length, first ambulation time after operation, length of hospital stay, total dosage of oral morphine, and pre-discharge satisfaction with surgery and WOMAC scores (P>0.05). At 4, 12, and 24 hours after operation, the resting and activity VAS scores in the “cocktail” group were lower than those in the LB group; at 60 and 72 hours postoperatively, the resting VAS scores in the LB group were lower than those in the “cocktail” group, with the activity VAS scores also being lower at 60 hours; all showing significant differences (P<0.05). There was no significant difference in the above indicators between the two groups at other time points (P>0.05). On the second postoperative day, the sleep scores of the LB group were significantly higher than those of the “cocktail” group (P<0.05), while there was no significant difference in sleep scores on the day of surgery and the first postoperative day (P>0.05). Additionally, the incidence of complications showed no significant difference between the two groups (P>0.05). ConclusionThe use of LB for LIA in UKA can provide prolonged postoperative pain relief; however, it does not demonstrate a significant advantage over the “cocktail” method in terms of short-term analgesic effects or reducing opioid consumption and early functional recovery after UKA. Nevertheless, LB may help reduce postoperative sleep disturbances, making it a recommended option for UKA patients with cardiovascular diseases and insomnia or other mental health issues.
Prosthesis loosening is the leading cause of postoperative revision in unicompartmental knee arthroplasty (UKA). The deviation of medial and lateral translational installation of the prosthesis during surgery is a common clinical phenomenon and an important factor in increasing the risk of prosthesis loosening. This study established a UKA finite element model and a bone-prosthesis fixation interface micromotion prediction model. The predicted medial contact force and joint motion of the knee joint from a patient-specific lower extremity musculoskeletal multibody dynamics model of UKA were used as boundary conditions. The effects of 9 femoral component medial and lateral translational installation deviations on the Von Mises stress of the proximal tibia, the contact stress, and the micro-motion of the bone prosthesis fixation interface were quantitatively studied. It was found that compared with the neutral position (a/A of 0.492), the lateral translational deviation of the femoral component significantly increased the tibial Von Mises stress and the bone-prosthesis fixation interface contact stress. The maximum Von Mises stress and the maximum contact stress of the fixation interface increased by 14.08% and 143.15%, respectively, when a/A was 0.361. The medial translational deviation of the femoral component significantly increased the bone-prosthesis fixation interface micro-motion. The maximum value of micromotion under the conditions of femoral neutral and medial translation deviation was in the range of 20–50 μm, which is suitable for osseointegration. Therefore, based on considerations such as the micromotion range suitable for osseointegration reported in the literature, the risk of reducing prosthesis loosening, and factors that may induce pain, it is recommended that clinicians control the mounting position of the femoral component during surgery within the safe range of 0–4 mm medial translation deviation.
Objective?To introduce the concept and clinical applications of rotational alignment of the femoral prosthesis in total knee arthroplasty (TKA) so as to avoide the postoperative complications caused by rotational alignment.?Methods?The clinical and experimental research literature about rotational alignment of the femoral prosthesis in TKA was extensively reviewed and analyzed.?Results?Femoral prosthesis malrotation can lead to flexion gap unbalanced and undesirable patellar track. Rotation alignment of the femoral prosthesis is defined with radiological and computer assisted technique at pre- and post-operation, which can make the rotation alignment of the femoral prosthesis and the function of the knee favorable.?Conclusion?In recent years, many surgical skills and new techniques of defining the rotational alignment are developed, and good clinical results are achieved.