From Jan. 1991 to Jan. 1994, 11 cases ofdifferent hip lesions with flexon contracture deformity were treated by combination of SmithPeterson and WatsonJones incisions in replacement of hip joint. All of them were followed-up for 1 to 3 years (an average of 1.9 years). According to pain, joint function, the excellent and good results were rated at 90.9%. This showed that from using the combined incisions, the hip joint was very well exposed, and release of hip flexion contracture could be acomplished in the same time. Bleeding fromoperation was reduced and the procedure was simple.
ObjectiveTo evaluate hip function and reinfection of the patients with hip infection sequelae after total hip arthroplasty (THA) treatment.MethodsA clinical data of 31 patients (31 hips) with hip infection sequelae, who were treated with THA between June 2010 and May 2017, was retrospectively analyzed. There were 18 males and 13 females, with an average age of 46.1 years (range, 20-71 years). There were pyogenic infection in 17 cases, tuberculous infection in 9 cases, and unknown source of infection in 5 cases. The average time from infection to cure was 13.9 months (range, 6-25 months). The average time from cure to operation was 23.4 years (range, 6-58 years) for patients with confirmed source of infection. According to Kim classification, 12 cases were rated as typeⅠ, 9 as typeⅡ, and 10 as type Ⅲ. There were 21 cases of osteoarthritis after dysplasia, 7 cases of pathologic dislocation, and 3 cases of hip ankylosis. After operation, the infection was assessed by physical signs and laboratory tests; X-ray film of the hip was taken to assess the skeletal structure of the hip and infectious lesion; the length of the lower limb was measured, and the function of the hip joint was evaluated by Harris score.ResultsAll patients were followed up 10-63 months (mean, 34 months). The result of bacterial culture was negative. The incisions healed by first intention. The sciatic nerve stimulation occurred in 1 case and posterior dislocation of the joint occurred in 1 case after operation. There was no recurrence of infection and no aseptic loosening of the prosthesis. According to Harris score, the function of the hip was rated as excellent in 8 cases, good in 19 cases, and fair in 4 cases at last follow-up; and the excellent and good rate of hip joint function was 87%. X-ray films showed no patchy bone density reduction, spot hardening, or light areas. The length of affected limb was not fully equal with the unaffected limb in 5 cases, and the difference between two sides ranged from 0.4 to 1.3 cm (mean, 0.6 cm). At last follow-up, all patients had no obvious claudication or sensation of unequal length.ConclusionTHA can obtain satisfactory hip function and has low risk of infection recurrence for the patients with hip infection sequelae, who were assessed as the hip infection in a dormant state.
Objective To compare the bone resorption between the proximal fixation of the anatomique benoist giraud(ABG) hip and the distal fixation of the anatomic medullary locking(AML) hip by the medium-term X-ray films, and to evaluate the clinical results of the two prostheses. Methods From January 1992 to December 1996, 298 patients (396 hips) underwent the total hip arthroplasty at Wilson Hospital in Korea. In 125 patients, 176 hips were ABG hips, including 103 avascularnecrosis hips, 57 dysplasia hips, and 16 other diseased hips; In the other 173 patient the remaining 220 hips were AML hips, including 147 avascular necrosis hips, 65 dysplasia hips, and 8 other diseased hips. The A-P X-ray imagings were followed up for 5-12 years averaged 8 years, and were compared with the immediate postoperative X-ray imagings. The bone resorption area was measured and the bone resorption cases were recorded according to the Gruen zone obsesvation. Results During operation, 2 ABG hips and 5 AML hips were cracked at the femoral diaphysis; 3 ABG hips and 1 AML hip were cracked at the metaphysis; 6 ABGhips and 3 AML hips were fractured because of trauma after operation; among them, 2 ABG hips needed the stem revision and the remaining hips underwent the openreduction and the internal fixation. During the follow-up, 9 ABG hips were revised, 7 hips of which developed the aseptic loosening. No AML hip was revised, but 3 AML hips developed the aseptic loosening. The bone resorption pattern in theABG and AML hips was similar. The bone resorption occurred most commonly in theGruen zones 1 and 7, and it extended from the metaphysis to the diaphysis. In the Guren zones 2, 5, 6 and 7, there were more AML hips than ABG hips that developed the bone resorption. The bone resorption area around the AML hip was larger than that around the ABG hip. Conclusion The stress shielding bone resorption usually occurs proximally to the union area of the bone and the prosthesis. The ABG prosthesis is a proximal fixation prosthesis, therefore, the stress shielding bone resorption can be reduced. The bone resorption around the AML prosthesis develops slowly within 10 years after operation. The stress shielding bone resoption may reach the summit within 10 years and it will not develop endlessly, so the prosthesis will be stable for a long time. The probabilityof the bone resorption in the ABG prosthesis is smaller than that in the AMLprosthesis. The bone resorption around the AML prosthesis may develop slowly after 10 years and will not affect the stability of the prosthesis for a long time.
Objective To investigate the surgical planning and the mid-term effectiveness of four major lower extremity arthroplasties (4JA) in patients with rheumatoid arthritis (RA). Methods A clinical data of 25 patients with RA, who received 4JA and were followed up more than 3 years between June 2012 and September 2018, was retrospectively analyzed. There were 3 males and 22 females, with an average age of 48.6 years (range, 27-80 years). The body mass index ranged from 16.0 to 28.4 kg/m2, with an average of 20.48 kg/m2. The duration of RA ranged from 2 to 35 years (median, 21 years). There were 8 cases (12 sides) of knee valgus, 6 cases (12 side) of acetabular retraction, and 5 cases (10 sides) of hip stiffness. Among them, 20 patients underwent hip surgery first, and 5 patients underwent knee surgery first. Hip joint function was evaluated by Harris score, Hip Disability and Osteoarthritis Outcome Score (HOOS), hip range of motion, and Trendelenburg sign; knee joint function was evaluated by American Hospital for Special Surgery (HSS) score, knee range of motion and muscle strength, and a timed up and go (TUG) test was performed at last follow-up. X-ray films were used to observe whether the prosthesis was loose or displaced. Results All 25 patients completed 4JA. Only 1 patient (1 side) had incision infection after operation, 3 patients (3 sides) had proximal femur fractures during operation. All patients were followed up 3.0-8.8 years, with an average of 5.8 years. At last follow-up, the Harris score, HOOS score, and range of motion of flexion, extension, and abduction of the hip joint significantly improved when compared with those before operation, and the patients with positive Trendelenburg sign decreased. The HSS score and range of motion of flexion and extension of the knee joint also significantly improved when compared with those before operation. There were significant differences in all indexes between pre- and post-operation (P<0.05). The muscle strength was grade V. The TUG test ranged from 7.8 to 15.34 seconds (mean,10.79 seconds). X-ray films showed the prosthesis was not loose or displaced. Conclusion When RA patients receive 4JA, adequate preoperative evaluation, rational selection of the timing and sequence of surgery, and maximal restoration of lower limb alignment can achieve good mid-term effectiveness.
It is clear that that bloody bone graft is better than tranditional nobloody bone graft. The autherdesigned the shelf oporation of gluteus minimus muscle pedicle ilinc graft in hip joint. Since 1986 , 14patients were operated. Follow-wp survey lasted 24 to 49 monthes. It was improved evidently forhip joint unsteadiness and clandicatory gait and bad complication did not hiappon. The operation wassimple and make use of materials nearby and union fastly. It didn t destroy myedynamia of ...
ObjectiveTo explore the clinical effect of total hip arthroplasty (THA) in the treatment of old central dislocation of the hip joint. MethodsBetween January 2010 and June 2014, 21 patients (21 hips) with old central dislocation of the hip joint underwent THA and autologous bone graft for acetabulum reconstruction. There were 13 males and 8 females, aged 60-75 years (mean, 67.4 years). The left hip was involved in 12 cases and the right hip in 9 cases, with a disease course of 1-20 years (mean, 9.6 years). The causes were falling from height in 6 cases, traffic accident in 9 cases, crushing in 4 cases, and others in 2 cases. Hip pain, limited activity, and lameness were the main clinical symptoms. Preoperative Harris score was 32.95±2.06 and visual analogue scale (VAS) was 8.14±0.73. ResultsPrimary healing of incision was obtained in all patients. The patients were followed up 1.9-6.4 years (mean, 4.6 years). The X-ray films showed bone graft fusion at 4-24 months (mean, 12.5 months); there were no complications of grafted bone absorption, osteolysis, and infection. During follow-up, no prosthetic loosening or sinking, and no translucent zones around the prosthesis were observed. Harris score was significantly improved to 87.67±2.01 at 1 week and 92.10±1.95 at 1 year; and VAS score was significantly decreased to 2.57±0.81 at 1 week and 0.19 ±0.51 at 1 year (P < 0.05). ConclusionTHA is an effective surgical treatment for old central dislocation of the hip joint, because it can restore normal hip rotation center and reconstruct the hip joint function.
In order to help a surgeon to determine a proper canal filing cutting path in a hip replacement operation conveniently, this paper presents a kind of probe with combined structure. Firstly, the doctor can use this kind of combined probe to choose canal filing cutting path. Then, the doctor can use computer to guide the surgeon to file femoral cavity along the selected canal filing cutting path. Through hip replacement corpse experiments, filing effects and used time of using combined probe group and separate control group were analyzed. The experiment results showed that the methods introduced in this paper could lower the difficulty of hip replacement operations, improve the implantation of hip stem prostheses further, and reduce the incidence of surgical complications.
Objective To review progress of clinical application ofmorselized bone and to investigate relative exploration on it.Methods The recent articles on morselized bone in the field of clinicand experimental research were extensively reviewed, and relative examination of morselized bone referring to method and mechanism were investigated carefully.Results Morselized bone worked well clinically, especially inrevision ofartificial total hip joint, and it was proved effective with lots of advantages.Conclusion Morselized bone functions well clinically. Although its mechanism requires a further research, it still has a promising value in clinical application.
Total hip replacement (THR) is replacing the prosthesis stem similar to human bone that takes advantage of the material with both good mechanical properties and biocompatibility to the damaged articular surface. Thus it can not only alleviate or even eliminate the pain but also effectively maintain the joint stability and freedom and restore its normal performance. Finite element analysis was used in this study to establish a 3D model of artificial hip stem, and explore its fatigue properties of different materials to ensure the safety and reliability. The calculating obtained two results of different metal hip prosthesis, including lifetime and deformation. The minimum service life of titanium prosthesis reaches 568 million times, which satisfies ISO standards, while the stainless steel does not suit to be a prosthesis material.
The orientation of the acetabular cup in hip joint anteroposterior radiograph is a key factor in evaluating the postoperative outcomes of total hip arthroplasty (THA). Currently, measurement of the acetabular cup anteversion angle primarily relies on manual drawing of auxiliary lines by orthopedic surgeons and calculations using scientific calculators. This study proposes an automated computer-aided measurement method for the acetabular cup anteversion angle based on hip joint anteroposterior radiograph. The proposed method segments hip prosthesis images using an improved Otsu algorithm, identifies feature points at the acetabular cup opening by combining circle-fitting theory and the cup’s geometric characteristics, and fits an ellipse to the cup opening to calculate the anteversion angle. A total of 104 hip joint anteroposterior radiographs, including 71 right-sided and 81 left-sided prostheses, were analyzed. Two orthopedic surgeons independently measured the postoperative anteversion angles, and the results were compared with computer-generated measurements for correlation analysis. Spearman and Pearson correlation analyses demonstrated significant correlations between the proposed method and manual measurements for both the right group (r = 0.795, P < 0.01) and the left group (r = 0.859, P < 0.01). This method provides a reliable reference for orthopedic surgeons to assess postoperative prognosis.