Objective To investigate the feasibility and effectiveness of the novel bone hook combined with finger-guided technique in the treatment of irreducible intertrochanteric femoral fractures in elderly. Methods Between January 2021 and August 2023, 23 elderly patients with irreducible intertrochanteric femoral fractures were treated with the novel bone hook combined with finger-guided technique. There were 10 males and 13 females; the age ranged from 68 to 93 years (mean, 76.2 years). The time from injury to operation ranged from 36 to 76 hours (mean, 51.2 hours). According to the classification standard proposed by TONG Dake et al in 2021, there were 10 cases of typeⅠA, 1 case of typeⅠB, 6 cases of type ⅡA, 4 cases of type ⅡB, and 2 cases of type ⅡC. The operation time, intraoperative blood loss, intraoperative fluoroscopy frequences, and quality of fracture reduction were recorded. The fracture healing time and occurrence of postoperative complications were observed during follow-up. At last follow-up, the Harris scoring system was used to evaluate the hip joint function. Results The operation time was 42-95 minutes (mean, 52.1 minutes). The intraoperative blood loss was 40-420 mL (mean, 126.5 mL). Intraoperative fluoroscopy was performed 14-34 times (mean, 20.7 times). According to the criteria proposed by Chang et al, the quality of fracture reduction was rated as good in 20 cases and acceptable in 3 cases. All patients were followed up 6-20 months (mean, 10.2 months). X-ray film showed that all fractures healed with the healing time of 3.0-5.5 months (mean, 4.0 months). At last follow-up, the Harris score of the hip joint ranged from 82 to 97 points (mean, 90.4 points). Among them, 14 cases were rated as excellent and 9 cases as good. No complication such as coxa vara, cutting of the cephalomedullary nail, nail withdrawal, or nail breakage occurred during follow-up. Conclusion The treatment of elderly patients with irreducible intertrochanteric femoral fractures by using the novel bone hook combined with finger-guided technique can achieve high-quality fracture reduction and fixation, and has a good effectiveness.
ObjectiveTo explore effectiveness of reduction and internal fixation via modified anterolateral supra-fibular-head approach in treatment of tibial plateau fractures involving posterolateral column.MethodsBetween January 2016 and September 2018, 19 patients diagnosed as tibial plateau fractures involving posterolateral column were treated with reduction and internal fixation via modified anterolateral supra-fibular-head approach. There were 11 males and 8 females with an average age of 43.2 years (range, 28-65 years). The causes of tibial fracture were traffic accident (12 patients), falling injury (5 patients), and falling from height (2 patients). According to the Schatzker typing, the tibial fractures were rated as type Ⅱ in 9 cases, type Ⅲ in 4 cases, type Ⅴ in 4 cases, and type Ⅵ in 2 cases. The time from injury to operation was 5-13 days (mean, 8.5 days). There were 2 patients with osteoporosis. The operation time, intraoperative blood loss, and postoperative complications were recorded. The knee X-ray film was reviewed regularly to observe the fracture healing. At last follow-up, the fracture reductions were evaluated by Rasmussen radiological score. The knee joint function was evaluated by Hospital for Special Surgery (HSS) score system.ResultsThe average operation time was 95 minutes (range, 65-130 minutes). The average intraoperative blood loss was 220 mL (range, 150-350 mL). All incisions healed by first intention. No complications such as infection or deep venous thrombosis occurred. All patients were followed up 12-20 months (mean, 15.4 months). X-ray films showed that the fractures healed with the healing time of 12-20 weeks (mean, 14.5 weeks). No complications such as loosening or breakage of internal fixation occurred. At last follow-up, according to the Rasmussen radiological score, the fracture reductions were evaluated as excellent in 13 cases, good in 4 cases, fair in 1 case, and poor in 1 case. HSS scores of knee joint function were excellent in 14 cases, good in 3 cases, fair in 1 case, and poor in 1 case. The knee joint range of motion was 90°-135°, with an average of 113.4°.ConclusionApplication of modified anterolateral supra-fibular-head approach in reduction and internal fixation for tibial plateau fractures involving posterolateral column has the advantages of full exposure, less trauma, safety, and reliable reduction and fixation.
Objective To design a new extracorporeal reduction device for percutaneous pedicle screw fixation of thoracolumbar fractures (short for “new reduction device”), and to evaluate its effectiveness. Methods According to the mechanism of thoracolumbar fractures and biomechanics characteristic of reduction, a new reduction device was designed and used in a combination with long U-shaped hollow pedicle screw system. Between January 2014 and January 2016, 36 patients (group A) with single segment thoracolumbar fracture without neurological complications underwent percutaneous pedicle screw fixation, and the clinical data were compared with those of another 39 patients (group B) with thoracolumbar fracture underwent traditional open pedicle screw fixation. There was no significant difference in gender, age, cause of injury, classification of fractures, segments of fractures, injury to operation interval, height percentage of injury vertebrae, and kyphotic angle between 2 groups (P>0.05). The 2 groups were compared in terms of operation time, length of incision, intraoperative blood loss, drainage volume, visual analogue scale (VAS) at postoperative 24 hours, fluoroscopy frequency, ambulation time, height percentage of injury vertebrae, kyphotic angle and correction. Results Group A was significantly better than group B in the operation time, length of incision, intraoperative blood loss, drainage volume, VAS score at postoperative 24 hours, and ambulation time (P<0.05). However, fluoroscopy frequency of group B was significantly less than that of group A (P<0.05). All patients were followed up 11.2 months on average (range, 7-15 months). There was no intraoperative and postoperative complications of iatrogenic nerve injury, infection, breakage of internal fixation. Mild pulling-out of pedicle screws occurred in 1 case of group A during operation. The kyphotic angle and height percentage of the fractured vertebral body were significantly improved at 3 days after operation when compared with preoperative ones (P<0.05), but no significant difference was found between 2 groups at 3 days after operation (P>0.05). Conclusion Minimally invasive extracorporeal reduction device for percutaneous pedicle screw fixation is an effective and safe treatment of thoracic vertebrae and lumbar vertebrae fractures, because of little trauma, less bleeding, and quicker recovery.
Objective To investigate the effectiveness of disc reduction and anchorage in treatment of diacapitular condylar fracture with disc displacement. Methods Between June 2019 and June 2021, 20 patients (27 sides) with diacapitular condylar fractures with disc displacement were treated with disc reduction and anchorage combined with internal fixation. There were 15 males and 5 females with a median age of 40 years (range, 8-65 years). The fractures were caused by falling from height in 3 cases, traffic accident in 3 cases, and falling in 14 cases. Among them, there were 13 cases of unilateral fracture and 7 cases of bilateral fractures. Five sides were type A fractures and 22 sides were type B. There were 14 simple diacapitular condylar fractures, 12 diacapitular condylar fractures combined with mandibular chin fractures, and 1 diacapitular condylar fracture combined with mandibular angle fracture. The maximum opening was 5-20 mm (mean, 9.7 mm). The time from injury to operation was 4-20 days, with an average of 11.6 days. The postoperative imaging examination was performed to evaluate the reduction of fracture and disc. The maximum opening at 6 months after operation was recorded, and the clinical dysfunction index (Di) of Helkimo index was used to evaluate the temporomandibular joint function. Results All incisions healed by first intention. All 20 patients were followed up 6-10 months (mean, 8 months). Postoperative imaging examination showed that 27 fractures were well reduced, of which 26 were anatomically reduced and 1 was basically reduced; the reduction of the temporomandibular joint disc was excellent in 25 sides, good in 1 side, and poor in 1 side, and the effective rate of disc reduction and anchorage was 96.3%. The occlusion relationship of the patient was stable and basically reached the pre-injury level, the incision scar was hidden, and the mouth opening significantly improved when compared with the preoperative level. The maximum mouth opening was 32-40 mm (mean, 36.8 mm) at 6 months after operation. Maximum opening was more than 35 mm in 17 cases. At last follow-up, joint function reached Di 0 grade in 8 sides, DiⅠ grade in 18 sides, and DiⅡ grade in 1 side. After operation, 2 cases of opening deviation, 1 case of joint click, and 2 cases of temporary disappearance of frontal striae on affected side occurred, which recovered to normal after symptomatic treatment. ConclusionFor diacapitular condylar fractures with disc displacement, it is necessary to adopt disc reduction and anchorage at the same time of fracture reduction and internal fixation, which can achieve good clinical results.
Objective This review summarized the first 10-year progresses and controversies in the concept of anteromedial cortical support reduction, to provide references for further study and clinical applications.Methods Relevant domestic and foreign literature on cortical support reduction was extensively reviewed to summarize the definition of positive, neutral, and negative support, anteromedial cortices at the inferior corner, intraoperative technical tips for fracture reduction, radiographic assessment at different periods, comparison between positive versus neutral and medial versus anterior support, and the clinical efficacy of Chang reduction quality criteria (CRQC) and postoperative stability score. Results Anteromedial cortical support reduction was only focused on the cortex of anteromedial inferior corner, with no concern the status of lateral wall or lesser trochanter. Anteromedial cortex was seldom involved by fracture comminution, it was thicker, denser, and stronger, and was the key for mechanical buttress of the head-neck fragment to share compression load. Positive, neutral, and negative support were also called “extramedullary, anatomic, and intramedullary reduction”, respectively. There was hardly seen parallel cortical apposition, but characterized by some kinds of head-neck rotation, for example 10°-15° flexed rotation for positive cortical contact and support. Due to intraoperative compression and postoperative impaction, the status of cortical support may be changed at different time of radiographic examination. The positive medial cortex support was more reliable with less reduction loss than its neutral counterpart, and the anterior cortex contact was more predictive than the medial cortex for final results. As incorporation the bearing of cortex apposition and using a 4-point score, CRQC demonstrated more efficacy and was gradually accepted and applied in the evaluation of trochanteric fracture reduction quality. Postoperative stability score (8 points) provided a assessment tool for early weight-bearing in safety to prevent mechanical failure. Conclusion Anteromedial cortical support reduction is a key point for stability reconstruction in the treatment of trochanteric femur fractures. Evidence has definitely shown that non-negative (positive and neutral) is superior to negative (loss of cortical support). There is a tendency that positive cortex support is superior to neutral, but high quality study with large sample size is needed for a clear conclusion.
ObjectiveTo explore effectiveness of intermediate screw assisted reduction and fixation technique in the treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures. Methods A clinical data of 22 patients with Schatzker type Ⅴ and Ⅵ tibial plateau fractures, who were admitted between June 2022 and December 2023 and met the selection criteria, was retrospectively analyzed. During operation, the intermediate screw assisted reduction and fixation technique was used. There were 14 males and 8 females with an average age of 46.3 years (range, 17-65 years). The fractures were caused by traffic accident in 13 cases, by falls in 5 cases, and by falling from height in 4 cases. According to Schatzker classification criteria, 9 cases were type Ⅴ and 13 cases were type Ⅵ. The interval between injury and operation was 5-12 days (mean, 7.9 days). The operation time, intraoperative fluoroscopy times, and length of hospital stay were recorded. The range of motion of knee joint and Hospital for Special Surgery (HSS) score were recorded at last follow-up. X-ray films were taken to review the fracture healing. Rasmussen score, tibial plateau varus angle (TPVA), and posterior tibial slope (PTS) were estimated before operation, at immediate after operation, and at last follow-up in order to evaluate the fracture reduction effect and postoperative outcome. Results The operation time was 85-140 minutes (mean, 103.9 minutes). Intraoperative fluoroscopy was performed 7-15 times (mean, 10.1 times). All incisions healed by first intention after operation, and no complication such as nerve or blood vessel injury occurred. The length of hospital stay ranged from 8 to 17 days (mean, 12.4 days). All patients were followed up 10-22 months (mean, 14.8 months). At last follow-up, the range of motion of knee joint was 110°-140° (mean, 125°). HSS score was rated as excellent in 16 cases, good in 5 cases, and fair in 1 case, with an excellent and good rate of 95.5%. X-ray films reexamination showed that all fractures healed with the healing time of 12-17 weeks (mean, 14.8 weeks). No internal fixation failure occurred. Rasmussen score, TPVA, and PTS at immediate after operation and at last follow-up were significantly superior to those before operation (P<0.05). And there was no significant difference between immediately after operation and last follow-up (P>0.05). Conclusion The treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures with intermediate screw assisted reduction and fixation technique is reliable, which can reduce the difficulty of reduction and fixation, improve the efficiency of reduction and fixation, reduce the operation time, achieve satisfactory reduction and fixation effect and postoperative prognosis, and achieve good recovery of knee joint function.
Objective To explore the effectiveness of proximal femoral nail antirotation (PFNA) combined with minimally invasive clamp reduction technique by Kocher pincers in the treatment of irreducible intertrochanteric femoral fracture in the elderly. Methods The clinical data of 35 elderly patients with irreducible intertrochanteric femoral fractures who were treated with PFNA combined with minimally invasive clamp reduction technique by Kocher pincers between January 2016 and December 2022 were retrospectively analysed. There were 16 males and 19 females, aged from 63 to 95 years (mean, 75.2 years). The causes of injury included traffic accident in 3 cases and falling in 32 cases. The time from injury to operation was 2-11 days (mean, 3.6 days). According to AO/Orthopaedic Trauma Association (AO/OTA) classification system for intertrochanteric fractures, there were 14 cases of type A1, 18 cases of type A2, and 3 cases of type A3. According to the displacement of fracture by intraoperative fluoroscopy, there were 5 cases with only coronal displacement, 17 cases with only sagittal displacement, and 13 cases with both coronal and sagittal displacement. The operation time, intraoperative blood loss, rate of hemoglobin decline at 1 day after operation, length of hospital stay, and fracture healing time were recorded. The reduction quality of fracture during operation was evaluated according to reduction quality criteria proposed by Chang et al. The Harris scoring system was used to evaluate the hip joint function at last follow-up. Results The operation time was 45-105 minutes (mean, 54.4 minutes); the intraoperative blood loss was 80-300 mL (mean, 116.3 mL). The reduction quality of fracture during operation was good in 22 cases (62.9%) and acceptable in 13 cases (37.1%). The rate of hemoglobin decline at 1 day after operation ranged from 6.2% to 18.6% (mean, 10.2%); the length of hospital stay was 5-18 days (mean, 7.2 days). One case died of respiratory failure due to pulmonary infection, 2 cases were lost to follow-up, and the remaining 32 cases were followed up 6-24 months (mean, 10.6 months). All 32 patients achieved bony union and the healing time was 3-9 months (mean, 3.6 months). There was no complication such as incision infection, internal fixation failure, or coxa varus during follow-up. At last follow-up, the Harris score of hip joint was 67-96 (mean, 88.9); among them, 19 cases were excellent, 10 cases were good, 2 cases were fair, and 1 case was poor, with an excellent and good rate of 90.6%. Conclusion For the elderly patients with irreducible intertrochanteric femoral fracture, the application of PFNA combined with minimally invasive clamp reduction technique by Kocher pincers can achieve high-quality fracture reduction, which has the advantages of simple reduction operation, less trauma, and can avoid the radiation exposure of operators during maintenance reduction.
Objective To explore effectiveness of positive support reduction and internal fixation in the treatment of femoral neck fractures. Methods A clinical data of 74 patients with femoral neck fractures treated with hollow screw internal fixation between September 2017 and September 2021 was retrospectively analyzed. Based on the quality of fracture reduction, they were divided into positive support reduction group (group A, n=25), negative support reduction group (group B, n=21), and anatomical reduction group (group C, n=28). There was no significant difference in baseline data such as gender, age, cause of injury, disease duration, fracture side, Garden classification, and fracture line position classification between groups (P>0.05). The occurrence of complications such as early fixation failure, femoral neck shortening, non-union of fractures, and femoral head necrosis in three groups, as well as the Harris score of the hip joint were recorded and compared. Results All patients had primary healing of incisions after operation and were followed up more than 12 months. The follow-up time for groups A, B, and C was (21.1±5.7), (22.6±4.3), and (21.9±4.1) months, respectively; there was no significant difference between groups (P>0.05). There was no significant difference in the incidences of non-union of fractures, early internal fixation failure, and the femoral head necrosis between groups (P>0.05). The incidence and length of femoral neck shortening, and the hip Harris score at last follow-up in groups A and C were all superior to those in the group B, with significant difference (P<0.05). There was no significant difference in the above indicators between groups A and C (P>0.05). Conclusion Positive support reduction can provide a good biomechanical environment for the healing of femoral neck fractures, thereby achieving a higher fracture healing rate, reducing the occurrence of femoral neck shortening, minimizing the function of hip joint, and achieving effectiveness similar to anatomical reduction.
Objective To evaluate the safety and effectiveness of reducing posterior malleolar fractures via the modified Rammelt transfibular approach. Methods A retrospective analysis was conducted on 26 patients with ankle fractures who met the selection criteria and were admitted between September 2023 and May 2024. There were 13 males and 13 females, aged from 14 to 59 years (median, 43.5 years). Causes of injury included traffic accident (1 case), falls (7 cases), and sprains (18 cases). Time from injury to operation ranged from 1 to 13 days (mean, 3.9 days). According to the Lauge-Hansen classification, there were 5 supination-external rotation (SER) type Ⅲ fractures and 21 SER type Ⅳ fractures. According to the Bartoní?ek classification for posterior malleolar fractures, there were 12 type Ⅱ fractures, 10 type Ⅲ fractures, and 4 type Ⅳ fractures. During operation, the fracture was exposed via the modified Rammelt transfibular approach; then, the fracture reduction was achieved under direct vision using techniques such as towel clip traction, posterolateral compression, and lifting with a posterior transverse periosteal elevator; finally, the fracture was fixed using anteroposterior cannulated screws or Kirschner wires. The incision healing was observed after operation. At 4 months after operation, X-ray film and CT were reviewed to evaluate the quality of fracture reduction. The medial clear space, tibiofibular clear space, and the anterior/posterior tibiofibular syndesmotic distances were measured. At last follow-up, the ankle function was assessed using the American Orthopaedic Foot & Ankle Society (AOFAS) score and the range of motion was measured. Results The marginal necrosis occurred in 2 lateral malleolar incisions, and superficial infection occurred in 1 lateral malleolar incision; the remaining incisions healed by first intention. All 26 patients were followed up 13-21 months (mean, 15.6 months). X-ray films showed that fractures in 25 patients achieved clinical union within 3-8 months (mean, 5.4 months); 1 case had delayed union of the lateral malleolus. At 4 months after operation, no significant difference was found between the injured and healthy sides in the medial clear space, tibiofibular clear space, or the anterior/posterior tibiofibular syndesmotic distances (P>0.05). No malreduction of the posterior malleolus or the tibiofibular syndesmosis occurred. At last follow-up, the AOFAS score ranged from 80 to 100 (mean, 91.9). The range of motion ranged from 17° to 22° (mean, 21.0°) in active ankle dorsiflexion and from 40° to 49° (mean, 44.6°) in plantar flexion. Internal fixator was removed in 12 patients at 1 year after operation, with no ankle instability occurring. Ankle joint degeneration was observed in 1 patient at last follow-up. Conclusion The modified Rammelt transfibular approach is a safe and reliable technique. It enables precise reduction under direct vision, improves the quality of reduction for the distal tibial articular surface and the tibiofibular syndesmosis, and provides satisfactory ankle functional recovery in short-term follow-up.
ObjectiveTo introduce the reduction concept of anteromedial cortical support in the treatment of intertrochanteric fracture, summarize the history, characteristics, biomechanics, and clinical applications, discuss the unsolved problems and prospect the future directions.MethodsRelevant domestic and foreign studies on cortical support reduction of intertrochanteric fracture in recent years were reviewed. Conclusions were drawn combined with clinical experience.ResultsThe positive cortical supportive reduction of intertrochanteric fracture, as a stable non-anatomical fracture reduction technique, has dual effects on mechanical buttress and biological bone healing. It does not increase the difficulty of doctors’ surgical procedure. For patients, it decreases the loss of femoral neck length, the loss of neck-shaft angle, the incidence rate of coxa vara, and maintains stable mechanical structure of the pelvis. It also shows a lower rate of instrument-related complications, and higher limb function scores. The mechanical stability of medial cortex apposition is more important than that of anterior cortex. For the best stability of the fracture, both sides should get positive support reduction pattern.ConclusionAnteromedial cortical support reduction can improve the postoperative stability of intertrochanteric fracture, enable better imaging and functional prognosis. As a kind of non-anatomic form of functional reduction, it can be used as a suboptimal choice secondary to anatomic reduction.