ObjectiveTo explore effectiveness of intermediate screw assisted reduction and fixation technique in the treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures. Methods A clinical data of 22 patients with Schatzker type Ⅴ and Ⅵ tibial plateau fractures, who were admitted between June 2022 and December 2023 and met the selection criteria, was retrospectively analyzed. During operation, the intermediate screw assisted reduction and fixation technique was used. There were 14 males and 8 females with an average age of 46.3 years (range, 17-65 years). The fractures were caused by traffic accident in 13 cases, by falls in 5 cases, and by falling from height in 4 cases. According to Schatzker classification criteria, 9 cases were type Ⅴ and 13 cases were type Ⅵ. The interval between injury and operation was 5-12 days (mean, 7.9 days). The operation time, intraoperative fluoroscopy times, and length of hospital stay were recorded. The range of motion of knee joint and Hospital for Special Surgery (HSS) score were recorded at last follow-up. X-ray films were taken to review the fracture healing. Rasmussen score, tibial plateau varus angle (TPVA), and posterior tibial slope (PTS) were estimated before operation, at immediate after operation, and at last follow-up in order to evaluate the fracture reduction effect and postoperative outcome. Results The operation time was 85-140 minutes (mean, 103.9 minutes). Intraoperative fluoroscopy was performed 7-15 times (mean, 10.1 times). All incisions healed by first intention after operation, and no complication such as nerve or blood vessel injury occurred. The length of hospital stay ranged from 8 to 17 days (mean, 12.4 days). All patients were followed up 10-22 months (mean, 14.8 months). At last follow-up, the range of motion of knee joint was 110°-140° (mean, 125°). HSS score was rated as excellent in 16 cases, good in 5 cases, and fair in 1 case, with an excellent and good rate of 95.5%. X-ray films reexamination showed that all fractures healed with the healing time of 12-17 weeks (mean, 14.8 weeks). No internal fixation failure occurred. Rasmussen score, TPVA, and PTS at immediate after operation and at last follow-up were significantly superior to those before operation (P<0.05). And there was no significant difference between immediately after operation and last follow-up (P>0.05). Conclusion The treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures with intermediate screw assisted reduction and fixation technique is reliable, which can reduce the difficulty of reduction and fixation, improve the efficiency of reduction and fixation, reduce the operation time, achieve satisfactory reduction and fixation effect and postoperative prognosis, and achieve good recovery of knee joint function.
ObjectiveTo review and evaluate the basic principles and advantages of orthopedic robot-assisted technology, research progress, clinical applications, and limitations in the field of traumatic orthopedics, especially in fracture reduction robots. Methods An extensive review of research literature on the principles of robot-assisted technology and fracture reduction robots was conducted to analyze the technical advantages and clinical efficacy and shortcomings, and to discuss the future development trends in this field. Results Orthopedic surgical robots can assist orthopedists in intuitive preoperative planning, precise intraoperative control, and minimally invasive operations. It greatly expands the ability of doctors to evaluate and treat orthopedic trauma. Trauma orthopedic surgery robot has achieved a breakthrough from basic research to clinical application, and the preliminary results show that the technology can significantly improve surgical precision and reduce surgical trauma. However, there are still problems such as insufficient evaluation of effectiveness, limited means of technology realization, and narrow clinical indications that need to be solved. ConclusionRobot-assisted technology has a broad application prospect in traumatic orthopedics, but the current development is still in the initial stage. It is necessary to strengthen the cooperative medical-industrial research, the construction of doctors’ communication platform, standardized training and data sharing in order to continuously promote the development of robot-assisted technology in traumatic orthopedics and better play its clinical application value.
ObjectiveTo summarize the evolving concept and research progress on stability reconstruction in the surgical treatment of intertrochanteric fracture.MethodsRelated literature and author’s own experience concerning the surgical treatment of intertrochanteric fracture were reviewed and analyzed in terms of fracture pathoanatomy, stable and unstable pattern, adequate and in-adequate reduction, primary and secondary stability, postoperative stability evaluation, and early weight-bearing.ResultsIntertrochanteric fracture occur at the translational area of cervico-trochanteric junction, which has a nature tendency to varus instability. Fracture reduction quality is the paramount factor and is evaluated by two views, the anteroposterior and lateral Garden alignment and cortex apposition between the head-neck fragment and the femoral shaft. Rather than the posteromedial lesser trochanteric frag ment, the cortical support concept (positive, neutral, negative) emphasizes the reduction of anteromedial cortex to a nonanatomic positive apposition or an " anatomic” neutral apposition in intraoperative fluoroscopy. Postoperative radiographic stability score provides a quantitative assessment for early weight-bearing standing and walking. However, some fractures may lose cortical contact and buttress (negative) during the process of postoperative telescoping and secondary stability. Further studies are needed to elucidate the risk factors such as tilting, swing or rotation of the head-neck fragment, and propose new preventive methods.ConclusionStability reconstruction of intertrochanteric fracture requires adequate fracture reduction with Garden alignment and anteromedial cortical support apposition, and reliable sustainment by internal fixation implants. Early weight-bearing standing and walking is safe in patients with perfect postoperative stability score.
Objective To design a new extracorporeal reduction device for percutaneous pedicle screw fixation of thoracolumbar fractures (short for “new reduction device”), and to evaluate its effectiveness. Methods According to the mechanism of thoracolumbar fractures and biomechanics characteristic of reduction, a new reduction device was designed and used in a combination with long U-shaped hollow pedicle screw system. Between January 2014 and January 2016, 36 patients (group A) with single segment thoracolumbar fracture without neurological complications underwent percutaneous pedicle screw fixation, and the clinical data were compared with those of another 39 patients (group B) with thoracolumbar fracture underwent traditional open pedicle screw fixation. There was no significant difference in gender, age, cause of injury, classification of fractures, segments of fractures, injury to operation interval, height percentage of injury vertebrae, and kyphotic angle between 2 groups (P>0.05). The 2 groups were compared in terms of operation time, length of incision, intraoperative blood loss, drainage volume, visual analogue scale (VAS) at postoperative 24 hours, fluoroscopy frequency, ambulation time, height percentage of injury vertebrae, kyphotic angle and correction. Results Group A was significantly better than group B in the operation time, length of incision, intraoperative blood loss, drainage volume, VAS score at postoperative 24 hours, and ambulation time (P<0.05). However, fluoroscopy frequency of group B was significantly less than that of group A (P<0.05). All patients were followed up 11.2 months on average (range, 7-15 months). There was no intraoperative and postoperative complications of iatrogenic nerve injury, infection, breakage of internal fixation. Mild pulling-out of pedicle screws occurred in 1 case of group A during operation. The kyphotic angle and height percentage of the fractured vertebral body were significantly improved at 3 days after operation when compared with preoperative ones (P<0.05), but no significant difference was found between 2 groups at 3 days after operation (P>0.05). Conclusion Minimally invasive extracorporeal reduction device for percutaneous pedicle screw fixation is an effective and safe treatment of thoracic vertebrae and lumbar vertebrae fractures, because of little trauma, less bleeding, and quicker recovery.
ObjectiveTo measure the rotation angle of the head-neck fragment of intertrochanteric fracture after cephalomedullary nail fixation by three-dimensional CT imaging, and to explore its clinical significance.MethodsThe clinical data of 68 patients with unstable intertrochanteric fracture of AO/Orthopaedic Trauma Association (AO-OTA) type 31-A2 treated with cephalomedullary nail fixation and with complete intraoperative fluoroscopy and postoperative three-dimensional CT imaging data between July 2016 and October 2018 were retrospectively analyzed. Among them, there were 21 males and 47 females, aged 68-93 years, with an average age of 81.8 years. There were 31 cases of AO/OTA type 31-A2.2 and 37 cases of 31-A2.3. Fracture reduction quality was evaluated according to Baumgaertner et al. and Chang et al. criteria. The anteromedial cortical contact or not of each patient was observed by three-dimensional CT imaging on T3DView software after operation. The rotation of head-neck fragments were divided into three types: non-rotation, flexion rotation, and hyperextension rotation. The rotation angles of each type were measured and the relationship between the rotation type of the head-neck fragments and the contact of the anteromedial cortex was analyzed.ResultsThe reduction and fixation of the small trochanter were not performed in 68 patients. According to Baumgaertner et al. criteria, the quality of fracture reduction was excellent in 15 cases (22.1%), acceptable in 50 cases (73.5%), and poor in 3 cases (4.4%). According to Chang et al. criteria, 31 cases were excellent (45.6%), 33 cases were acceptable (48.5%), and 4 cases were poor (5.9%). Thirty-nine cases (57.4%) received anteromedial cortical support and 29 cases (42.6%) did not receive cortical support. Three-dimensional CT imaging showed non-rotation in 12 cases (17.6%), flexion rotation in 39 cases (57.4%), and hyperextension rotation in 17 cases (25.0%). There were 7 cases (58.3%), 30 cases (76.9%), and 2 cases (11.8%) of cortical support in non-rotation group, flexion rotation group, and hyperextension rotation group, respectively. The rotation angles were (1.05±0.61), (13.96±6.17), (8.21±3.88)°, respectively. There were significant differences between groups (P<0.05).ConclusionIn the unstable intertrochanteric fracture after cephalomedullary nail fixation, the rotation of head-neck fragment exists in most patients, and the types of flexion rotation and non-rotation can easily obtain cortical support reduction.
Objective To investigate the effectiveness of disc reduction and anchorage in treatment of diacapitular condylar fracture with disc displacement. Methods Between June 2019 and June 2021, 20 patients (27 sides) with diacapitular condylar fractures with disc displacement were treated with disc reduction and anchorage combined with internal fixation. There were 15 males and 5 females with a median age of 40 years (range, 8-65 years). The fractures were caused by falling from height in 3 cases, traffic accident in 3 cases, and falling in 14 cases. Among them, there were 13 cases of unilateral fracture and 7 cases of bilateral fractures. Five sides were type A fractures and 22 sides were type B. There were 14 simple diacapitular condylar fractures, 12 diacapitular condylar fractures combined with mandibular chin fractures, and 1 diacapitular condylar fracture combined with mandibular angle fracture. The maximum opening was 5-20 mm (mean, 9.7 mm). The time from injury to operation was 4-20 days, with an average of 11.6 days. The postoperative imaging examination was performed to evaluate the reduction of fracture and disc. The maximum opening at 6 months after operation was recorded, and the clinical dysfunction index (Di) of Helkimo index was used to evaluate the temporomandibular joint function. Results All incisions healed by first intention. All 20 patients were followed up 6-10 months (mean, 8 months). Postoperative imaging examination showed that 27 fractures were well reduced, of which 26 were anatomically reduced and 1 was basically reduced; the reduction of the temporomandibular joint disc was excellent in 25 sides, good in 1 side, and poor in 1 side, and the effective rate of disc reduction and anchorage was 96.3%. The occlusion relationship of the patient was stable and basically reached the pre-injury level, the incision scar was hidden, and the mouth opening significantly improved when compared with the preoperative level. The maximum mouth opening was 32-40 mm (mean, 36.8 mm) at 6 months after operation. Maximum opening was more than 35 mm in 17 cases. At last follow-up, joint function reached Di 0 grade in 8 sides, DiⅠ grade in 18 sides, and DiⅡ grade in 1 side. After operation, 2 cases of opening deviation, 1 case of joint click, and 2 cases of temporary disappearance of frontal striae on affected side occurred, which recovered to normal after symptomatic treatment. ConclusionFor diacapitular condylar fractures with disc displacement, it is necessary to adopt disc reduction and anchorage at the same time of fracture reduction and internal fixation, which can achieve good clinical results.
Objective This review summarized the first 10-year progresses and controversies in the concept of anteromedial cortical support reduction, to provide references for further study and clinical applications.Methods Relevant domestic and foreign literature on cortical support reduction was extensively reviewed to summarize the definition of positive, neutral, and negative support, anteromedial cortices at the inferior corner, intraoperative technical tips for fracture reduction, radiographic assessment at different periods, comparison between positive versus neutral and medial versus anterior support, and the clinical efficacy of Chang reduction quality criteria (CRQC) and postoperative stability score. Results Anteromedial cortical support reduction was only focused on the cortex of anteromedial inferior corner, with no concern the status of lateral wall or lesser trochanter. Anteromedial cortex was seldom involved by fracture comminution, it was thicker, denser, and stronger, and was the key for mechanical buttress of the head-neck fragment to share compression load. Positive, neutral, and negative support were also called “extramedullary, anatomic, and intramedullary reduction”, respectively. There was hardly seen parallel cortical apposition, but characterized by some kinds of head-neck rotation, for example 10°-15° flexed rotation for positive cortical contact and support. Due to intraoperative compression and postoperative impaction, the status of cortical support may be changed at different time of radiographic examination. The positive medial cortex support was more reliable with less reduction loss than its neutral counterpart, and the anterior cortex contact was more predictive than the medial cortex for final results. As incorporation the bearing of cortex apposition and using a 4-point score, CRQC demonstrated more efficacy and was gradually accepted and applied in the evaluation of trochanteric fracture reduction quality. Postoperative stability score (8 points) provided a assessment tool for early weight-bearing in safety to prevent mechanical failure. Conclusion Anteromedial cortical support reduction is a key point for stability reconstruction in the treatment of trochanteric femur fractures. Evidence has definitely shown that non-negative (positive and neutral) is superior to negative (loss of cortical support). There is a tendency that positive cortex support is superior to neutral, but high quality study with large sample size is needed for a clear conclusion.
Objective To summarize the morphological characteristics of sagittal beak-like deformity of head-neck fragment in femoral intertrochanteric fractures and to investigate the technical skills in fracture reduction. Methods A clinical data of 31 patients with femoral intertrochanteric fractures between May 2021 and April 2023 was retrospectively analyzed. The fractures had sagittal beak-like deformity of head-neck fragment in all patients. There were 13 males and 18 females, with an average age of 76.2 years (range, 68-83 years). The time from injury to operation was 36-76 hours (mean, 51.2 hours). Fractures were classified as type A1.2 in 10 cases, type A1.3 in 11 cases, type A2.2 in 6 cases, and type A2.3 in 4 cases according to the AO/Orthopaedic Trauma Association (AO/OTA)-2018 classification; and as type A1.3 in 10 cases, type A2.1 in 11 cases, type A2.2 in 6 cases, type A2.3 in 2 cases, and type A2.4 in 2 cases according to a novel comprehensive classification for femoral intertrochanteric fractures proposed by the “Elderly Hip Fracture” Research Group of the Reparative and Reconstructive Surgery Committee of the Chinese Rehabilitation Medical Association. Based on preoperative X-ray films, CT scan and three-dimensional reconstruction, the fractures were classified into two types: type 1 (14 cases), with uncomplicated fracture morphology, severe bone interlocking and (or) soft tissue incarceration; type 2 (17 cases), with severe fracture crushing, obvious dissociation between bone blocks, and severe soft tissue hinge destruction. After the failure of the closed reduction, all patients underwent fracture reduction assisted with instrument via anterior minimal incision and proximal femoral nail antirotation nails internal fixation. The operation time, intraoperative fluoroscopy, intraoperative visible blood loss, length of hospital stay, and incidence of complications were recorded. The fracture reduction quality and stability score were assessed at immediate after operation under fluoroscopy. The fracture healing was evaluated and healing time was recorded by X-ray films. The pain visual analogue scale (VAS) score was performed at 48 hours after operation and Parker-Palmer activity score at 3 months after operation for function evaluation. ResultsThe operation time was 39-58 minutes (mean, 46.3 minutes); fluoroscopy was performed 13-38 times (mean, 23.5 times) during operation; the intraoperative visible blood loss was 45-90 mL (mean, 65.3 mL). The fracture reduction quality and stability score were rated as good in 29 cases and acceptable in 2 cases. The pain VAS score was 2-6 (mean, 3.1) at 48 hours after operation. Eleven patients developed deep vein thrombosis of the lower limbs after operation. Patients were hospitalized for 6-10 days (mean, 7.3 days). All patients were followed up 5-8 months (mean, 6.5 months). All fractures healed at 3.5-8.0 months after operation (mean, 4.5 months). Parker-Palmer activity score at 3 months after operation was 9 in 28 cases and 6 in 3 cases. Conclusion The femoral intertrochanteric fracture with sagittal beak-like deformity of head-neck fragment is difficult to manually reduce. The pin combined with cannulated screw insertion to the neck cortex can hold the fragment and assist fracture reduction, which is a simple and effective technique.
ObjectiveTo introduce the reduction concept of anteromedial cortical support in the treatment of intertrochanteric fracture, summarize the history, characteristics, biomechanics, and clinical applications, discuss the unsolved problems and prospect the future directions.MethodsRelevant domestic and foreign studies on cortical support reduction of intertrochanteric fracture in recent years were reviewed. Conclusions were drawn combined with clinical experience.ResultsThe positive cortical supportive reduction of intertrochanteric fracture, as a stable non-anatomical fracture reduction technique, has dual effects on mechanical buttress and biological bone healing. It does not increase the difficulty of doctors’ surgical procedure. For patients, it decreases the loss of femoral neck length, the loss of neck-shaft angle, the incidence rate of coxa vara, and maintains stable mechanical structure of the pelvis. It also shows a lower rate of instrument-related complications, and higher limb function scores. The mechanical stability of medial cortex apposition is more important than that of anterior cortex. For the best stability of the fracture, both sides should get positive support reduction pattern.ConclusionAnteromedial cortical support reduction can improve the postoperative stability of intertrochanteric fracture, enable better imaging and functional prognosis. As a kind of non-anatomic form of functional reduction, it can be used as a suboptimal choice secondary to anatomic reduction.
Objective To introduce a new fluoroscopic method for assessing the quality of medial and lateral joint surface reduction during internal fixation of patellar fractures and to summarize the clinical outcomes of patients treated using this method. Methods A retrospective analysis was conducted on the clinical data of 52 patients with patellar fractures treated between January 2018 and January 2022 who met the inclusion criteria. There were 27 male and 25 female patients, aged 21-75 years, with an average age of 62 years. The types of patellar fractures included 9 transverse fractures, 37 comminuted fractures, and 6 longitudinal fractures. According to the AO/Orthopaedic Trauma Association (AO-OTA)-2018 fracture classification, there were 21 cases of type 34A, 6 cases of type 34B, and 25 cases of type 34C. The time from injury to operation ranged from 1 to 5 days, with an average of 2.3 days. Treatments included internal fixation with hollow screws or hollow screw tension bands, with or without anchor repair. During operation, the medial and lateral joint surfaces of the patella were observed using the tangential fluoroscopic method to assess the smoothness of reduction of the median ridge, lateral joint surface, medial joint surface, and lateral joint edge. Patients were followed up regularly, and X-ray films were taken to observe fracture healing. Knee joint range of motion, B?stman score, and Lysholm score were used to evaluate functional recovery. Results The tangential fluoroscopic method for the medial and lateral joint surfaces of the patella during operation showed satisfactory reduction of the joint surfaces and good positioning of the implants. All patients were followed up 12-16 months, with an average of 13.4 months. During the follow-up, fracture displacement occurred in 1 case and titanium cable breakage in 1 case. All patella fractures healed successfully, with a healing time of 8-16 weeks (mean, 11.4 weeks). At last follow-up, knee joint range of motion ranged from 120° to 140°, with an average of 136°. The B?stman score ranged from 20 to 30, with an average of 28, yielding excellent results in 45 cases and good results in 7 cases. The Lysholm score ranged from 88 to 100, with an average of 93, yielding excellent results in 40 cases and good results in 12 cases. Conclusion The intraoperative application of the tangential fluoroscopic method for the medial and lateral joint surfaces of the patella can quickly determine the fluoroscopic plane of the patella, accurately assess the quality of fracture reduction and the position of internal fixator, thereby improving effectiveness.