    • Biomechanical analysis and effectiveness evaluation of zone Ⅰ+Ⅱ+Ⅲ reconstruction of hemipelvis with rod-screw prosthesis

      ObjectiveTo analyze the biomechanical properties of the rod-screw prosthesis based on a pelvic three-dimensional finite element model including muscle and ligament, and evaluate the effectiveness of zoneⅠ+Ⅱ+Ⅲ reconstruction of hemipelvis with rod-screw prosthesis in combination with clinical applications. Methods A total of 21 patients who underwent hemipelvic tumor resection (zoneⅠ+Ⅱ+Ⅲ) and rod-screw prosthesis reconstruction between January 2015 and December 2020 were selected as the research subjects. Among them, there were 11 males and 10 females; the age ranged from 16 to 64 years, with an average age of 39.2 years. There were 9 cases of chondrosarcoma, 7 cases of osteosarcoma, 3 cases of Ewing sarcoma, and 2 cases of undifferentiated pleomorphic sarcoma. According to the Musculoskeletal Tumor Society Score (MSTS) staging, there were 19 cases of stage ⅡB and 2 cases of stage Ⅲ. Preoperative Harris Hip Score (HHS) and MSTS score were 54.4±3.1 and 14.1±2.0, respectively. Intraoperative 15 cases underwent extensive resection, 5 cases underwent marginal resection, and 1 case underwent intralesional resection. The CT image of 1 patient after reconstruction was used to establish a three-dimensional solid model of the pelvis via Mimics23Suite and 3-matic softwares. At the same time, a mirror operation was used to obtain a normal pelvis model, then the two solid models were imported into the finite element analysis software Workbench 2020R1 to establish three-dimensional finite element models, and the biomechanical properties of the standing position were analyzed. The operation time, intraoperative blood loss, and operation-related complications were recorded, and the postoperative evaluation was carried out with HHS and MSTS scores. Finally, the local recurrence and metastasis were reviewed. ResultsFinite element analysis showed that the peak stress of the reconstructed pelvis appeared at the fixed S1, 2 rod-screw connections; the peak stress without muscles was higher than that after muscle construction, but much smaller than the yield strength of titanium alloy. The operation time was 250-370 minutes, with an average of 297 minutes; the amount of intraoperative blood loss was 3 200-5 500 mL, with an average of 4 009 mL. All patients were followed up 8-72 months, with an average of 42 months. There were 7 cases of pulmonary metastasis, of which 2 cases were preoperative metastasis; 5 cases died, 16 cases survived, and the 5-year survival rate was 72.1%. There were 3 cases of local recurrence, all of whom did not achieve extensive resection during operation. The function of the affected limbs significantly improved, and the walking function was restored. The HHS and MSTS scores were 75.2±3.0 and 20.4±2.0 at last follow-up, respectively, and the differences were significant when compared with those before operation (t=22.205, P<0.001; t=11.915, P<0.001). During follow-up, 2 cases of delayed incision healing, 2 cases of deep infection, 1 case of screw loosening, and 1 case of prosthesis dislocation occurred, and no other complication such as prosthesis or screw fracture occurred. Conclusion The stress and deformation distribution of the reconstructed pelvis are basically the same as normal pelvis. The rod-screw prosthesis is an effective reconstruction method for pelvic malignant tumors.

      Release date:2022-05-07 02:02 Export PDF Favorites Scan
    • Effects of different alveolar bone finite element models on the biomechanical responses of periodontal ligament

      In the study of oral orthodontics, the dental tissue models play an important role in finite element analysis results. Currently, the commonly used alveolar bone models mainly have two kinds: the uniform and the non-uniform models. The material of the uniform model was defined with the whole alveolar bone, and each mesh element has a uniform mechanical property. While the material of the elements in non-uniform model was differently determined by the Hounsfield unit (HU) value of computed tomography (CT) images where the element was located. To investigate the effects of different alveolar bone models on the biomechanical responses of periodontal ligament (PDL), a clinical patient was chosen as the research object, his mandibular canine, PDL and two kinds of alveolar bone models were constructed, and intrusive force of 1 N and moment of 2 Nmm were exerted on the canine along its root direction, respectively, which were used to analyze the hydrostatic stress and the maximal logarithmic principal strain of PDL under different loads. Research results indicated that the mechanical responses of PDL had been affected by alveolar bone models, no matter the canine translation or rotation. Compared to the uniform model, if the alveolar bone was defined as the non-uniform model, the maximal stress and strain of PDL were decreased by 13.13% and 35.57%, respectively, when the canine translation along its root direction; while the maximal stress and strain of PDL were decreased by 19.55% and 35.64%, respectively, when the canine rotation along its root direction. The uniform alveolar bone model will induce orthodontists to choose a smaller orthodontic force. The non-uniform alveolar bone model can better reflect the differences of bone characteristics in the real alveolar bone, and more conducive to obtain accurate analysis results.

      Release date:2021-06-18 04:50 Export PDF Favorites Scan
    • Finite element method simulating bursting process of multi-chamber flexible package infusion bag

      This study aims to overcome the shortcomings such as low efficiency, high cost and difficult to carry out multi-parameter research, which limited the optimization of infusion bag configuration and manufacture technique by experiment method. We put forward a fluid cavity based finite element method, and it could be used to simulate the stress distribution and deformation process of infusion bag under external load. In this paper, numerical models of infusion bag with different sizes was built, and the fluid-solid coupling deformation process was calculated using the fluid cavity method in software ABAQUS subject to the same boundary conditions with the burst test. The peeling strength which was obtained from the peeling adhesion test was used as failure criterion. The calculated resultant force which makes the computed peeling stress reach the peeling strength was compared with experiment data, and the stress distribution was analyzed compared with the rupture process of burst test. The results showed that considering the errors caused by the difference of weak welding and eccentric load, the flow cavity based finite element method can accurately model the stress distribution and deformation process of infusion bag. It could be useful for the optimization of multi chamber infusion bag configuration and manufacture technique, leading to cost reduction and study efficiency improvement.

      Release date:2021-08-16 04:59 Export PDF Favorites Scan
    • Biomechanical effects of three internal fixation modes on femoral subtrochanteric spiral fractures in osteoporotic patients by finite element analysis

      Objective The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture. MethodsTen female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect. ResultsIn the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode (P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes (P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences (P<0.05). ConclusionUnder static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.

      Release date:2023-06-07 11:13 Export PDF Favorites Scan
    • Research on the Surface Potential Distribution of Spinal Cord Based on Finite Element Analysis

      Finite element analysis can be used to study the change of the structure and the interior field intensity of human and animal body organs and tissues with simulation experiment. We in our research used finite element analysis software to analyze and solve the spinal cord surface potential problems, and investigated the transmission features of signals generated by interneurons in spinal nerves which were related with body motion control and sensory processing. A three dimensional model of electrical source in rat spinal cord was built, and the influence on potential distribution on spinal cord surface caused by position changes of electrical source in transverse direction and dorsoventral direction were analyzed and calculated. We obtained the potential distribution curves of spinal cord surface and found that the potential distribution on spinal cord surface showed monotone. In addition, potentials of some registration points were smaller than that of registration points around.

      Release date: Export PDF Favorites Scan
    • Finite Element Analysis of Intravascular Stent Based on ANSYS Software

      This paper adopted UG8.0 to bulid the stent and blood vessel models. The models were then imported into the finite element analysis software ANSYS. The simulation results of ANSYS software showed that after endothelial stent implantation, the velocity of the blood was slow and the fluctuation of velocity was small, which meant the flow was relatively stable. When blood flowed through the endothelial stent, the pressure gradually became smaller, and the range of the pressure was not wide. The endothelial shear stress basically unchanged. In general, it can be concluded that the endothelial stents have little impact on the flow of blood and can fully realize its function.

      Release date: Export PDF Favorites Scan
    • Numerical study on the effect of middle ear malformations on energy absorbance

      In order to study the effect of middle ear malformations on energy absorbance, we constructed a mechanical model that can simulate the energy absorbance of the human ear based on our previous human ear finite element model. The validation of this model was confirmed by two sets of experimental data. Based on this model, three common types of middle ear malformations, i.e. incudostapedial joint defect, incus fixation and malleus fixation, and stapes fixation, were simulated by changing the structure and material properties of the corresponding tissue. Then, the effect of these three common types of middle ear malformations on energy absorbance was investigated by comparing the corresponding energy absorbance. The results showed that the incudostapedial joint defect significantly increased the energy absorbance near 1 000 Hz. The incus fixation and malleus fixation dramatically reduced the energy absorbance in the low frequency, which made the energy absorbance less than 10% at frequencies lower than 1 000 Hz. At the same time, the peak of energy absorbance shifted to the higher frequency. These two kinds of middle ear malformations had obvious characteristics in the wideband acoustic immittance test. In contrast, the stapes fixation only reduced the energy absorbance in the low frequency and increased energy absorbance in the middle frequency slightly, which had no obvious characteristic in the wideband acoustic immittance test. These results provide a theoretical reference for the wideband acoustic immittance diagnosis of middle ear malformations in clinic.

      Release date:2021-04-21 04:23 Export PDF Favorites Scan
    • Biomechanical analysis of ankle-foot complex during a typical Tai Chi movement?Brush Knee and Twist Step

      The purpose of this study is to analyze the biomechanics of ankle cartilage and ligaments during a typical Tai Chi movement–Brush Knee and Twist Step (BKTS). The kinematic and kinetic data were acquired in one experienced male Tai Chi practitioner while performing BKTS and in normal walking. The measured parameters were used as loading and boundary conditions for further finite element analysis. This study showed that the contact stress of the ankle joint during BKTS was generally less than that during walking. However, the maximum tensile force of the anterior talofibular ligament, the calcaneofibular ligament and the posterior talofibular ligament during BKTS was 130 N, 169 N and 89 N, respectively, while it was only 57 N, 119 N and 48 N during walking. Therefore, patients with arthritis of the ankle can properly practice Tai Chi. Practitioners with sprained lateral ligaments of the ankle joint were suggested to properly reduce the ankle movement range during BKTS.

      Release date:2021-04-21 04:23 Export PDF Favorites Scan
    • Research on Energy Distribution During Osteoarthritis Treatment Using Shock Wave Lithotripsy

      Extracorporeal shock wave treatment is capable of providing a non-surgical and effective treatment modality for patients suffering from osteoarthritis. The major objective of current works is to investigate how the shock wave (SW) field would change if a bony structure exists in the path of the acoustic wave. Firstly, a model of finite element method (FEM) was developed based on Comsol software in the present study. Then, high-speed photography experiments were performed to record cavitation bubbles with the presence of mimic bone. On the basis of comparing experimental with simulated results, the effectiveness of FEM model could be verified. Finally, the energy distribution during extracorporeal shock wave treatment was predicted. The results showed that the shock wave field was deflected with the presence of bony structure and varying deflection angles could be observed as the bone shifted up in the z-direction relative to shock wave geometric focus. Combining MRI/CT scans to FEM modeling is helpful for better standardizing the treatment dosage and optimizing treatment protocols in the clinic.

      Release date: Export PDF Favorites Scan
    • Remodeling simulation of human femur under bed rest and spaceflight circumstances based on three dimensional finite element analysis

      Astronauts who are exposed to weightless environment in long-term spaceflight might encounter bone density and mass loss for the mechanical stimulus is smaller than normal value. This study built a three dimensional model of human femur to simulate the remodeling process of human femur during bed rest experiment based on finite element analysis (FEA). The remodeling parameters of this finite element model was validated after comparing experimental and numerical results. Then, the remodeling process of human femur in weightless environment was simulated, and the remodeling function of time was derived. The loading magnitude and loading cycle on human femur during weightless environment were increased to simulate the exercise against bone loss. Simulation results showed that increasing loading magnitude is more effective in diminishing bone loss than increasing loading cycles, which demonstrated that exercise of certain intensity could help resist bone loss during long-term spaceflight. At the end, this study simulated the bone recovery process after spaceflight. It was found that the bone absorption rate is larger than bone formation rate. We advise that astronauts should take exercise during spaceflight to resist bone loss.

      Release date:2017-12-21 05:21 Export PDF Favorites Scan