• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "enhancement" 17 results
    • A Blinding Comparative Study of Multiparametric Magnetic Resonance Imaging in Diagnosing Prostate Cancer

      ObjectiveTo compare the effectiveness of T2 weighted image (T2WI) and some compounded MRI techniques, including T2WI combined with magnetic resonance spectroscopy (T2WI+MRS), T2WI combined with diffusion weighted imaging (T2WI+DWI) and T2WI combined with dynamic contrast-enhancement [T2WI+(DCE-MRI)] respectively, with 1.5 T MR scanner in diagnosing prostate cancer through a blinding method. MethodsBetween March 2011 and April 2013, two observers diagnosed 59 cases with a blinding method. The research direction of radiologist A was to diagnose prostate cancer. The observers diagnosed and scored the cases with T2WI, T2WI+(DCE-MRI), T2WI+MRS, T2WI+DWI and compositive method respectively. The data were statistically analyzed with receiver operating characteristic (ROC) curve. ResultsAccording to the ROC curve, both observers got the sequence of area under curve (AUC) as T2WI+DWI > T2WI+(DCE-MRI) > T2WI+MRS > T2WI. On the basis of the result from observer A, the AUC from each technique was similar. The AUC of T2+DWI was slightly bigger than others. The specificity of single T2WI was the lowest; the sensitivity of T2WI was slightly higher. The AUC of the compositive method was marginally larger than T2WI+DWI. According to the result from observer B, the AUC of T2WI+DWI was obviously larger than the others. The AUC of single T2WI was much smaller than the other techniques. The single T2WI method had the lowest sensitivity and the highest specificity. The AUC of T2WI+DWI was slightly larger than the compositive method. The AUC of T2WI+(DCE-MRI), T2WI+MRS, single T2WI methods from observer A was obviously higher than those from the score of observer B. The AUC of T2WI+DWI from the two observers was similar. ConclusionThe method of combined T2WI and functional imaging sequences can improve the diagnosing specificity when a 1.5 T MR scanner is used. T2WI+DWI is the best method in diagnosing prostate cancer with least influence from the experience of observers in this research. The compositive method can improve the diagnosis of prostate cancer effectively, but when there are contradictions between different methods, the T2WI+DWI should be considered as a key factor.

      Release date: Export PDF Favorites Scan
    • Differential diagnosis significance of 3.0T MRI united-sequence examination forbenign and malignant breast lesions

      Objective To explore the differential diagnosis significance of 3.0T MRI united-sequences examination in the diagnosis of benign and malignant breast lesions. Methods A total of 67 breast lesions of 59 patients were collected prospectively, which be treated at the Sichuan Provincial People’s Hospital during July 2015 to January 2017. All patients were underwent bilateral breast 3.0T magnetic resonance plain scan, diffusion weighted imaging, and dynamic enhanced scan successively before surgical operation. Analysis of morphological features of the benign and malignant breast lesions, the time-signal intensity curve (TIC), the apparent diffusion coefficient (ADC), and the combination diagnosis of them were performed. Results Of all 59 patients, 67 lesions were confirmed by histopathology, including 18 benign lesions and 49 malignant lesions. The morphological features (including margin, shape, border, and evenness), the types of TIC of dynamic enhancement, and ADC value between the benign lesions and malignant lesions were statistically significant (P<0.05). The sensitivity and specificity of Fischer scoring system was 89.8% (44/49) and 61.1% (11/18) respectively. The sensitivity and specificity of TIC types was 83.7% (41/49) and 77.8% (14/18) respectively. The diagnostic threshold of ADC value was 1.012×10–3 mm2/s, with the sensitivity and specificity for the diagnosis was 91.8% (45/49) and 83.3% (15/18) respectively. The sensitivity and specificity of the combination of Fischer scoring system and TIC type for diagnosis between benign and malignant breast lesions was 95.9% (47/49) and 72.2% (13/18) respectively. The sensitivity and specificity of the combination of Fischer scoring system, TIC type, and ADC value for benign and malignant breast lesions was 98.0% (48/49) and 83.3% (15/18) respectively. Conclusion The combination of Fischer scoring system, TIC type, and diffusion-weighted imaging for the differential diagnosis between benign lesions and malignant lesions was more effective than single imaging method.

      Release date:2018-07-18 01:46 Export PDF Favorites Scan
    • Research progress of microphone array based front-end speech enhancement technology for cochlear implant

      Microphone array based methods are gradually applied in the front-end speech enhancement and speech recognition improvement for cochlear implant in recent years. By placing several microphones in different locations in space, this method can collect multi-channel signals containing a lot of spatial position and orientation information. Microphone array can also yield specific beamforming mode to enhance desired signal and suppress ambient noise, which is particularly suitable to be applied in face-to-face conversation for cochlear implant users. And its application value has attracted more and more attention from researchers. In this paper, we describe the principle of microphone array method, analyze the microphone array based speech enhancement technologies in present literature, and further present the technical difficulties and development trend.

      Release date:2019-08-12 02:37 Export PDF Favorites Scan
    • Research on phase modulation to enhance the feature of high-frequency steady-state asymmetric visual evoked potentials

      High-frequency steady-state asymmetric visual evoked potential (SSaVEP) provides a new paradigm for designing comfortable and practical brain-computer interface (BCI) systems. However, due to the weak amplitude and strong noise of high-frequency signals, it is of great significance to study how to enhance their signal features. In this study, a 30 Hz high-frequency visual stimulus was used, and the peripheral visual field was equally divided into eight annular sectors. Eight kinds of annular sector pairs were selected based on the mapping relationship of visual space onto the primary visual cortex (V1), and three phases (in-phase[0o, 0o], anti-phase [0o, 180o], and anti-phase [180o, 0o]) were designed for each annular sector pair to explore response intensity and signal-to-noise ratio under phase modulation. A total of 8 healthy subjects were recruited in the experiment. The results showed that three annular sector pairs exhibited significant differences in SSaVEP features under phase modulation at 30 Hz high-frequency stimulation. And the spatial feature analysis showed that the two types of features of the annular sector pair in the lower visual field were significantly higher than those in the upper visual field. This study further used the filter bank and ensemble task-related component analysis to calculate the classification accuracy of annular sector pairs under three-phase modulations, and the average accuracy was up to 91.5%, which proved that the phase-modulated SSaVEP features could be used to encode high- frequency SSaVEP. In summary, the results of this study provide new ideas for enhancing the features of high-frequency SSaVEP signals and expanding the instruction set of the traditional steady state visual evoked potential paradigm.

      Release date:2023-08-23 02:45 Export PDF Favorites Scan
    • A Modified Speech Enhancement Algorithm for Electronic Cochlear Implant and Its Digital Signal Processing Realization

      In order to improve the speech quality and auditory perceptiveness of electronic cochlear implant under strong noise background, a speech enhancement system used for electronic cochlear implant front-end was constructed. Taking digital signal processing (DSP) as the core, the system combines its multi-channel buffered serial port (McBSP) data transmission channel with extended audio interface chip TLV320AIC10, so speech signal acquisition and output with high speed are realized. Meanwhile, due to the traditional speech enhancement method which has the problems as bad adaptability, slow convergence speed and big steady-state error, versiera function and de-correlation principle were used to improve the existing adaptive filtering algorithm, which effectively enhanced the quality of voice communications. Test results verified the stability of the system and the de-noising performance of the algorithm, and it also proved that they could provide clearer speech signals for the deaf or tinnitus patients.

      Release date: Export PDF Favorites Scan
    • Imaging findings of cystic liver lesions

      Objective To summarize ultrasonography, CT and (or) MRI imaging features of cystic liver lesions so as to improve its diagnostic accuracy. Methods The literatures relevant imaging studies of different types of cystic liver lesions at home and abroad were searched. Then with the etiology as clue, the imaging fetures of ultrasonography, CT and (or) MRI plain scan and enhancement scan were summarized. Results The cystic liver lesions had many types, their imaging findings were different and existed overlaps. The diagnosis and differential diagnosis of atypical cases were difficult. ① For the simple hepatic cyst, it was a round cystic mass with water-like echo, density and signal. The boundary was clear, and there was no separation in the cyst, without contrast enhancement. The sensitivity and specificity of diagnosing were higher by ultrasonography and MRI as compared with CT. ② For the bile duct hamartoma and Caroli diease, they were manifested as multiple cysts, widely distributed in the whole liver, without enhancement for the most lesions. The multiple cystic lesions without communicating with the bile duct was the key sign of differential diagnosis for these two dieases. ③ Enhancing mural nodules were more common in cystadenocarcinoma than cystadenoma. The accurate diagnosis of biliary cystadenoma depended on combination of ultrasonography, CT, and MRI findings. ④ For the cystic liver metastatic tumor, it was multiple cystic neoplasms in the liver parenchyma or around the liver. CT was the main method for the diagnosis, and which showed that the density was lower than that of the liver parenchyma, peripheral ring-enhanced lesion as enhanced scan. It was easy to distinguish with simple hepatic cyst by MRI. ⑤ For the cystic hepatocellular carcinoma, it presented as a multilocular cystic solid tumor. The presence of tumor thrombus in portal vein could help to the diagnosis. ⑥ For the undifferentiated embryonal sarcoma, CT plain scan showed the cystic low density mass with clear boundary, the edge with calcification, enhanced scan showed that the soft tissue composition presented continuous strengthening sign. There was no specific signal in MRI plain scan, and the periphery of the tumor was slowly strengthening. ⑦ For the liver abscess, it was easy to diagnose because it had different characteristic features in different pathological phase, but it was misdiagnosis of intrahepatic cholangiocarcinoma when its symptoms were atypical. ⑧ The ultrasonography and the CT were the optimal methods for the hepatic cystic echinococcosis and the hepatic alveolar echinococcosis respectively. The significances of imaging were to determine the activity of hydatid cyst and to identify anatomy structure among alveolar echinococcosis, bile duct and blood vessel, and judge invasion or not, MRCP was important for diagnosis. Conclusions Abdominal ultrasonography could be used as the first choice for diagnosis of cystic liver lesions, CT and MRI could be used as effective supplementary methods for it. A combination of various imaging techniques is key to diagnosis. Moreover, number and morphology of lesion, and solid component or not are important imaging features of diagnosis and differential diagnosis of cystic liver lesion.

      Release date:2017-05-04 02:26 Export PDF Favorites Scan
    • Research progress on the efficacy of platelet-rich plasma with different properties on rotator cuff injury

      Arthroscopic rotator cuff repair is widely used clinically, but the phenomenon of re-tear after repair is still common. Due to the special structure of the tendon-bone junction, the promotion of tissue regeneration from the perspective of biological enhancement has attracted attention. Platelet-rich plasma (PRP) is a supraphysiological concentration of autologous platelets, which can promote the healing of rotator cuff injury after repair. However, due to the lack of clinical use standards, not all PRPs are the same, there are clear differences between liquid PRP and solid platelet-rich fibrin, and many studies have not differentiated their properties. This article reviews the research progress of different types of PRP in the repair of rotator cuff injury, aiming to provide some reference for clinical treatment selection.

      Release date:2022-11-24 04:15 Export PDF Favorites Scan
    • CT and MRI fusion based on generative adversarial network and convolutional neural networks under image enhancement

      Aiming at the problems of missing important features, inconspicuous details and unclear textures in the fusion of multimodal medical images, this paper proposes a method of computed tomography (CT) image and magnetic resonance imaging (MRI) image fusion using generative adversarial network (GAN) and convolutional neural network (CNN) under image enhancement. The generator aimed at high-frequency feature images and used double discriminators to target the fusion images after inverse transform; Then high-frequency feature images were fused by trained GAN model, and low-frequency feature images were fused by CNN pre-training model based on transfer learning. Experimental results showed that, compared with the current advanced fusion algorithm, the proposed method had more abundant texture details and clearer contour edge information in subjective representation. In the evaluation of objective indicators, QAB/F, information entropy (IE), spatial frequency (SF), structural similarity (SSIM), mutual information (MI) and visual information fidelity for fusion (VIFF) were 2.0%, 6.3%, 7.0%, 5.5%, 9.0% and 3.3% higher than the best test results, respectively. The fused image can be effectively applied to medical diagnosis to further improve the diagnostic efficiency.

      Release date:2023-06-25 02:49 Export PDF Favorites Scan
    • Research of front-end speech enhancement and beamforming algorithm based on dual microphoneforcochlear implant

      Speech enhancement methods based on microphone array adopt many microphones to record speech signal simultaneously. As spatial information is increased, these methods can increase speech recognition for cochlear implant in noisy environment. Due to the size limitation, the number of microphones used in the cochlear implant cannot be too large, which limits the design of microphone array beamforming. To balance the size limitation of cochlear implant and the spatial orientation information of the signal acquisition, we propose a speech enhancement and beamforming algorithm based on dual thin uni-directional / omni-directional microphone pairs (TP) in this paper. Each TP microphone contains two sound tubes for signal acquisition, which increase the overall spatial orientation information. In this paper, we discuss the beamforming characteristics with different gain vectors and the influence of the inter-microphone distance on beamforming, which provides valuable theoretical analysis and engineering parameters for the application of dual microphone speech enhancement technology in cochlear implants.

      Release date:2019-06-17 04:41 Export PDF Favorites Scan
    • Value of CT arterial enhancement fraction based on histogram analysis in severity of liver cirrhosis

      ObjectiveTo investigate the diagnostic performance of parameters of arterial enhancement fraction (AEF) based on enhanced CT with histogram analysis in the severity of liver cirrhosis.MethodsThe patients with liver cirrhosis clinically confirmed and met the inclusion criteria were included from January 2016 to December 2018 in the First Affiliated Hospital of Chengdu Medical College, then them were divided into grade A, B, and C according to the Child-Pugh score. Meanwhile, the patients without liver disease were selected as the control group. All patients underwent the upper abdomen enhanced CT scan with three-phase and the biochemical examination of liver function. The parameters of AEF histogram were obtained by using the CT Kinetics software, and the aspartic aminotransferase and platelet ratio index (APRI) was calculated. The differences of parameters of AEF histogram and APRI among these patients with liver cirrhosis and without liver disease were analyzed. The diagnostic performance was evaluated by using the area under curve (AUC) of receivers operating characteristic curve.ResultsEighty-five patients with liver cirrhosis were included in this study, including 25, 41, and 19 patients with grade A, B, and C of Child-Pugh score, respectively, and there were 20 patients in the control group. The consistencies in measuring the parameters of AEF histogram twice for the same observer and between the two observers were good (intraclass correlation coefficient was 0.938 and 0.907, respectively). The mean, median, and kurtosis of AEF histogram and the APRI among the grade A, B, C of Child-Pugh score, and control group had significant differences (all P<0.001) and these indexes were positively correlated with the severity of liver cirrhosis (rs=0.811, P<0.001; rs=0.827, P<0.001; rs=0.731, P<0.001; rs=0.711, P<0.001). The AUC of the mean, median, kurtosis, and APRI in diagnosing grade A of liver cirrhosis was 0.829, 0.841, 0.747, and 0.718, respectively; which in diagnosing grade B of liver cirrhosis was 0.847, 0.734, 0.704, and 0.736, respectively; in diagnosing grade C of liver cirrhosis was 0.646, 0.825, 0.782, and 0.853, respectively.ConclusionThe mean and median of AEF histogram parameters based on enhanced CT with three-phase and serological APRI are useful in diagnosis of grage A, B, and C of liver cirrhosis, respectively.

      Release date:2020-02-24 05:09 Export PDF Favorites Scan
    2 pages Previous 1 2 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南