• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "diameter" 30 results
    • The Changes in Structure and Function of Left Ventricular in COPD Patients

      Objective To analyze the influence of COPD on the structure and function of left ventricular. Methods Sixty-nine COPD patients ( mean age: 69. 0 ±7. 8 yrs) and forty healthy controls ( mean age: 67. 8 ±7. 6 yrs) were enrolled in this study. Both groups underwent Doppler echocardiography.Heart rate ( HR) were recorded. Left ventricular end-diastolic volume ( LVEDV) , left ventricular enddiastolic diameter ( LVEDD) , interventricular septum( IVS) , stroke volume ( SV) , and cardiac output ( CO)were measured. The changes of left ventricular were compared between the COPD patients and the healthy controls, and also between the COPD patients with or without chronic cor pulmonale. Results Compared with the healthy controls, movement range of IVS, LVEDD, LVEDV, and SV reduced significantly ( P lt;0. 05) , and HR raised significantly in the COPD patients ( P lt; 0. 05) . CO had no significant difference between two groups ( P gt;0. 05) . Sub-group analysis indicated that the thickness and movement range of IVSwere greater in the patients with cor pulmonale secondary to COPD than those without cor pulmonale ( P lt;0. 05) . Conclusions In COPD patients, left ventricular chamber size decreases, and left ventricular systolic function is impaired. Left ventricular function is impaired more severe in cor pulmonale secondary to COPD than COPD without cor pulmonale.

      Release date: Export PDF Favorites Scan
    • Mid- and long-term effectiveness and failure causes analysis of large-head metal-on-metal total hip arthroplasty

      Objective To explore the effectiveness and failure causes of large-head metal-on-metal total hip arthroplasty (large-head MoM THA). Methods Between March 2007 and May 2010, 159 patients (183 hips) underwent large-head MoM THA, and the clinical data were analyzed. There were 50 females (54 hips) and 109 males (129 hips) with an average age of 50 years (range, 20-78 years). Single hip was involved in 135 cases (left hip in 69 cases and right hip in 66 cases) and double hips in 24 cases. The causes included femoral head necrosis in 74 cases (93 hips), Legg-Calve-Perthes in 1 case (1 hip), osteoarthritis in 18 cases (19 hips), developmental dysplasia of the hip in 17 cases (18 hips), osteoarthritis after hip septic infection in 8 cases (8 hips), traumatic arthritis of the hip in 6 cases (6 hips), femoral neck fracture in 17 cases (17 hips), ankylosing spondylitis in 8 cases (11 hips), rheumatoid arthritis of hip in 9 cases (9 hips), and adult onset Still’s disease in 1 case (1 hip). Before operation, visual analogue scale (VAS) was 6.59±0.87; Harris score was 45.99±8.07. Results Healing of incisions by first intention was achieved, and no operative complication occurred. The patients were followed up 1.2-8.2 years (mean, 6.1 years). Implant failure was observed in 15 cases (17 hips), and the 5-year survival rate of large-head MoM THA was 91.80% (168/183). The causes of implant failure after THA were inflammatory pseudotumor in 4 cases (4 hips), acetabular aseptic loosening in 3 cases (3 hips), osteolysis in 4 cases (5 hips), acetabular aseptic loosening combined with inflammatory pseudotumor in 3 cases (3 hips), and functional disused in 1 case (2 hips). Of them, 9 cases (11 hips) did not receive revision surgery for various reasons, while 6 cases (6 hips) underwent revision surgery at 1.2-5.4 years (mean 3.7 years) after large-head MoM THA. At last follow-up, VAS and Harris score were 1.72±1.48 and 81.37±10.75 respectively, showing significant differences when compared with preoperative scores (t=–35.547,P=0.000;t=33.823,P=0.000). The function was excellent in 44 hips, good in 89 hips, fair in 33 hips, and poor in 17 hips. Conclusion Large-head MoM THA has a high revision rate during mid- and long-term follow-up because of inflammatory pseudotumor, acetabular aseptic loosening, and osteolysis. Early revision can effectively improve the function of the hip and improve patients’quality of life.

      Release date:2017-03-13 01:37 Export PDF Favorites Scan
    • RELATIONSHIP BETWEEN TIBIA CALLUS DIAMETER RATIO AND PROGNOSIS DURING TIBIA LENGTHENING

      Objective To investigate the relationship between the tibia callus diameter ratio(CDR) and prognosis during tibial distraction and the occurrenceof late deformity or fracture. Methods We measured tibiallengthening callus diameter and added up the cases of angular deformity and fracture in 68 casesfrom January 1996 to December 2001, to calculated callus diameter ratios and compare the relationship between the tibia callus diameter during tibial distraction and the occurrence of late callus angular deformity or fracture. Results In 23 cases of CDRlt;80%, 13 cases had new bone fracture, 21 cases had angular deformity gt;5 degree. In 6 cases of 81%lt;CDRlt;85%, there were 4 cases of angular deformity gt;5 degree. In the other 39 cases of CDRgt;85%, there were no fracture and angular deformity. Conclusion When the CDR was gt;85%, there wereno angular deformity and fracture, but when the CDR was lt;80%, the complications of fracture and angular deformity occur. CDR is a better alarming index for preventing the complications occurring in tibial lengthening.

      Release date: Export PDF Favorites Scan
    • Study on the surgical indication for patients with simple ascending aortic dilatation

      ObjectiveTo compare the ascending aortic diameter and postoperative outcomes of patients with simple ascending aortic dissection or simple ascending aortic dilatation and to study the reliability of the surgical indication in present guideline for Chinese patients with ascending aortic dilatation.MethodsThe clinical data of patients with aortic aneurysm and aortic dissection who underwent surgery at Beijing Anzhen Hospital, Capital Medical University from 2010 to 2017 were retrospectively reviewed. After exclusion of patients with Marfan syndrome, heart valve and other diseases, 139 patients were divided into two groups: a simple ascending aorta dilatation group (56 patients) and a simple ascending aortic dissection group (83 patients). The ascending aortic diameter and postoperative outcomes of two groups were compared. ResultsThe inner ascending aortic diameter (57.30±9.41 mm vs. 50.72±9.53 mm, P <0.001) and the inner ascending aortic diameter index (31.12±5.38 vs. 27.22±6.40, P<0.001) in the simple ascending aorta dilatation group were significantly greater than those in the simple ascending aortic dissection group. For male patients, the results were similar (60.28±10.80 mm vs. 47.40±6.53 mm; 30.00±6.33 vs. 23.60±3.72, both P<0.001). But for the female patients, there was no significant difference between the two groups (54.90±7.47 mm vs. 53.81±10.84 mm; 32.03±4.37 vs. 30.58±6.56, both P>0.05). The mortality, the incidence of tracheotomy and postoperative reopen rate in the simple ascending aortic dissection group were higher.ConclusionIn this study, the inner diameter of the ascending aorta in the group of ascending aorta is mostly < 5.5 cm. In our opinion, the present surgical indication for Chinese patients with ascending aortic dilatation is not enough. In the future clinical studies, we also need to find more reasonable surgical indications.

      Release date:2019-10-12 01:36 Export PDF Favorites Scan
    • Effectiveness of multiple small-diameter drilling decompression combined with hip arthroscopy for early osteonecrosis of the femoral head

      Objective To evaluate the effectiveness of multiple small-diameter drilling decompression combined with hip arthroscopy for early oeteonecrosis of the femoral head (ONFH). Methods Between March 2010 and December 2013, 91 patients with early ONFH were treated with the operation of multiple small-diameter drilling decompression combined with hip arthroscopy in 39 cases (53 hips, group A) or with drilling decompression alone in 52 cases (74 hips, group B). The patients in 2 groups had obvious hip pain and limited motion before operation. There was no significant difference in gender, age, etiology, effected side, stage of osteonecrosis, and preoperative Harris score between 2 groups (P>0.05). Results All operations succeeded and all incisions healed by first intention. The operation time was significantly longer in group A [(73.3±10.6) minutes] than in group B [(41.5±7.2) minutes] (t=8.726, P=0.000). Temporary of sciatic nerve apraxia after operation occurred in 2 patients of group A, and no complication occurred in other patients. Patients were followed up 24-52 months (mean, 39.3 months) in group A and 24-48 months (mean, 34.6 months) in group B. At last follow-up, the Harris scores were 83.34±8.76 in group A and 76.61±9.22 in group B, showing significant differences when compared between 2 groups (t=–4.247, P=0.029) and when compared with preoperative values in 2 groups (t=–10.327, P=0.001; t=–8.216, P=0.008). X-ray films showed that the collapse of the femoral head was observed in 6 hips (1 hip at stage Ⅰand 5 hips at stage Ⅱ) in group A, and in 16 hips (4 hips at stageⅠand 12 hips at stage Ⅱ) in group B; and hip arthroplasty was performed. The total effective rates were 88.68% (47/53) in group A and 78.38% (58/74) in group B, respectively; showing significant difference between 2 groups (χ2=5.241, P=0.041). Conclusion Multiple small-diameter drilling decompression combined with hip arthroscopy is effective in pain relief, improvement of hip function, slowing-down the process of femoral head necrosis, delaying the need for total hip arthroplasty in patients with early ONFH.

      Release date:2017-09-07 10:34 Export PDF Favorites Scan
    • Effect of Inner Diameter of Pancreatic Duct Following Pancreaticoduodenectomy on Pancreatic Fistula

      Objective To analyze the effect of inner diameter of pancreatic duct following pancreaticoduodenectomy on pancreatic fistula. Methods From January 1995 to December 2008, 256 patients underwent pancreaticoduodenectomy were divided into four groups based on the types of pancreaticojejunostomy: end-to-side “mucosa-to-mucosa” anastomosis group (n=115), end-to-end “mucosa-to-mucosa” anastomosis group (n=71), end-to-end invaginated pancreaticojejunostomy group (n=43) and pancreaticogastrostomy group (n=27). Alternatively, 238 patients were divided into two groups according to drainage ways: stenting tube for internal drainage group (n=132) and stenting tube for external drainage group (n=106). Furthermore, 233 cases were divided into three groups on the basis of inner diameter of pancreatic duct: ≤0.2 cm group (n=54), 0.2-0.4 cm group (n=93) and ≥0.4 cm group (n=76). Then, the incidence rate of pancreatic fistula of each group was compared. Results The incidence of pancreatic fistula was 8.20% (21/256). The incidence of pancreatic fistula for different types of pancreaticojejunostomy was as follow: end-to-side “mucosa-to-mucosa” anastomosis group (7.83%, 9/115), end-to-end “mucosa-to-mucosa” anastomosis group (7.04%, 5/71), end-to-end pancreaticogastrostomy invaginated group (13.95%, 6/43) and pancreaticogastrostomy group (3.70%, 1/27), in which there wasn’t significant difference in 4 groups (χ2=2.763,P=0.430). There was no significant difference of the incidence of pancreatic fistula between stenting tube for internal drainage group (9.10%, 12/132) and stenting tube for external drainage group (8.49%, 9/106), χ2=0.126, P=0.722. The incidence of pancreatic fistula in ≥0.4 cm group, 0.2-0.4 cm group and ≤0.2 cm group was respectively 0, 15.05% (14/93) and 11.11%(6/54), and the difference was significant (χ2=12.009, P=0.002). No correlation was found between the incidence of pancreatic fistula of different inner diameter of pancreatic duct and the types of pancreaticojejunostomy (χ2=1.878, P=0.598). Conclusion The inner diameter of pancreatic duct is an important factor for postoperative pancreatic fistula. No relationship is found between the types of pancreaticojejunostomy and pancreatic fistula in this study.

      Release date:2016-09-08 11:05 Export PDF Favorites Scan
    • Effect of respiratory effort on inferior vena cava diameter variability

      Objective To analyze the quantitative relationship between respiratory effort and inferior vena cava (IVC) diameter variability in healthy adults, and explore the effects of respiratory effort on the fluid responsiveness with IVC diameter variability. Methods From October 2022 to May 2023, a cross-sectional study was conducted in healthy young subjects who met the criteria. Respiratory effort was evaluated by using portable pulmonary function to measure the subjects’ inspiratory conditions in three states (quiet breathing, moderate inspiration, and maximal inspiration). At the same time, the IVC internal diameter was measured by bedside ultrasound and the IVC diameter variability was calculated. The correlation between inspiratory volume and IVC diameter variation was analyzed, and the receiver operator characteristic (ROC) curve was drawn. The sensitivity and specificity of fluid responsiveness induced by inspiratory effort were predicted according to the area under the ROC curve (AUC). Results A total of 95 subjects were screened, aged 27.13±5.77 years, of whom 30 (32%) subjects were males. During quiet breathing, 41.1% of subjects had IVC inner diameter variation ≥50%. For moderate inspiration, it was 68.4%. At maximum inspiration, this proportion is more than 85%. Inspiratory volume was moderately positively correlated with IVC diameter variation, and the correlation coefficient r=0.45. With the IVC diameter variation ≥50% as the positive criterion for fluid responsiveness, the AUC of fluid responsiveness induced by inspiratory effort was 0.73 (95% confidence interval 0.67 - 0.78, P<0.001), and the inspiratory volume threshold was 13 mL/kg ideal body weight when the maximum Youden index was 0.41. That is, moderate force breathing can induce fluid responsiveness, with sensitivity of 79.57% and specificity of 61.62%. Conclusion The degree of respiratory effort significantly affects the IVC inner diameter variation, and there may be false positives in the evaluation of fluid responsiveness according to IVC inner diameter variation in the case of spontaneous breathing.

      Release date:2024-07-29 01:12 Export PDF Favorites Scan
    • Assessment of the internal mammary artery using ultrasound in patients with coronary artery disease before coronary artery bypass grafting

      ObjectiveTo investigate the feasibility and effectiveness of using ultrasound to evaluate the internal mammary artery (IMA) and explore the related factors affecting the quality of IMA.MethodsFrom July 2020 to January 2021, for patients who underwent coronary artery bypass grafting at the Department of Cardiovascular Surgery, Fuwai Hospital, ultrasound was applied to measure bilateral IMA at the parasternal second intercostal space. There were 62 males and 18 females with an average age of 59.9±8.3 years. The clinical data of the patients were recorded and analyzed.ResultsA total of 160 IMA were measured. The IMA was detected in 99.4% (159/160), and the one that was not measured was proved to be occluded by enhanced CT. A total of 157 (98.1%) IMA intima were smooth, 2 (1.3%) were found to have uneven intimal thickening and less smooth, and only 1 (0.6%) was occluded. The intravascular diameter, peak systolic flow rate, peak diastolic flow rate, and blood flow rate of the left second intercostal IMA were 1.9±0.3 mm, 66.8±17.7 cm/s, 6.4 (0.0, 9.7) cm/s, 19.7±9.4 mL/min; and those of the right one were 2.1±0.3 mm, 69.7±18.5 cm/s, 6.0 (0.0, 9.2) cm/s and 22.8±11.5 mL/min, respectively. IMA vessel diameter and blood flow were greater on the right than those on the left side in the same individual (P<0.01). In univariate analysis, sex and body surface area were the factors that influenced the size of the IMA vessel among different individuals, and by linear regression analysis, the size of the IMA vessel was only related to body surface area among different individuals. On univariate analysis, diabetes mellitus was the only factor affecting IMA blood flow, with a mean reduction in blood flow of 18.4% (left) and 21.7% (right) in the diabetic group (P<0.05).ConclusionPreoperative evaluation of the IMA using ultrasound over the parasternal second intercostal space is easy, noninvasive, and has a high success rate. The internal diameter of the IMA is positively correlated with body surface area, and blood flow is significantly reduced in patients with diabetes.

      Release date:2023-03-01 04:15 Export PDF Favorites Scan
    • Influence of different sintering temperatures on mesoporous structure and ectopic osteogenesis of biphasic calcium phosphate ceramic granule materials

      ObjectiveTo detect the difference in the osteogenesis ability of biphasic calcium phosphate (BCP) ceramic granular materials with different mesoporous diameters prepared at different sintering temperatures through in vivo and in vitro experiments, so as to provide evidence for screening BCP materials with better clinical application parameters.MethodsThree kinds of BCP (materials 1, 2, 3) were prepared by mixing hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP) at a ratio of 8∶2 and sintered at 1 050, 1 150, and 1 250℃ for 3 hours, respectively. The internal porosity and the diameter, volume, and area of the mesopore were measured by Brunauer-Emmett-Teller test (BET); the composition of the material was evaluated by X-ray diffraction (XRD); the microscopic surface morphology of the material was observed by scanning electron microscopy (SEM). The 3rd generation bone marrow mesenchymal stem cells (BMSCs) from Sprague-Dawley rats were co-cultured with the materials 1, 2, and 3 for 7 days in vitro respectively (groups A, B, and C), and the cells adhesion on the materials was observed by SEM and phalloidine staining, respectively. Cell proliferation activity was measured by cell counting kit 8 method. In vivo, 9 muscle bags were made in dorsal muscles of 9 beagles, respectively. The muscle bags were randomly divided into 3 groups (3 per beagle in each group) and materials 1, 2, and 3 were placed into the muscle bags of groups A, B, and C, respectively. After 1, 2, and 3 months of operation, 3 beagles were anesthetized and the samples were stained with HE, Masson, and Safranin, and the bone formation area ratio in the BCP gap was calculated. Real-time fluorescence quantitative PCR (qRT-PCR) was performed to detect the expressions of bone-related genes [including alkaline phosphatase (ALP), osteopontin (OPN), and osteocalcin (OC)].ResultsThe BET test showed that with the increase of sintering temperature, the internal porosity of the particles did not change significantly, but the diameter, volume, and area of the mesopores gradually decreased. The XRD detection showed that the XRD waves of HA and β-TCP could be seen in all 3 kinds of materials; SEM showed that there were widely distributed macropores on the surface of 3 kinds of BCPs, and the interpores connected with the others. In vitro, BMSCs adhered and proliferated on the surfaces of 3 kinds of BCPs, and the cell biocompatibility of the materials in groups B and C was better than that in group A. In vivo, obvious osteoid tissue deposition could be observed in the intergranular space of 3 kinds of BCPs from 2 months after implantation. The bone formation area ratio of each group increased with time. The bone formation area ratio in group A was significantly higher than that in groups B and C at 2 and 3 months after implantation, and in group A than in group B at 1 month (P<0.05). qRT-PCR showed that the expressions of osteogenic related genes peaked at 2 months in group A, and gradually increased with time in groups B and C. The relative expressions of ALP and OPN mRNAs in group A were significantly higher than those in groups B and C at 1 month after implantation, the relative expression of OC mRNA in group A was significantly higher than that in groups B and C at 2 months after operation, the relative expression of ALP mRNA in groups B and C and the relative expression of OPN mRNA in group B were significantly higher than those in group A, all showing significant differences (P<0.05); there was no significant difference in the relative expression of each gene among the other groups at each time point (P>0.05).ConclusionThe mesoporous diameter of BCP decreases with the increase of sintering temperature. Different mesoporous diameters lead to different ectopic osteogenesis of BCP materials. BCP material with mesoporous diameter of 12.57 nm has better osteogenic ability which can activate the osteogenic gene earlier. The mesoporous diameter is expected to be an adjustable index for optimizing the osteogenic capacity of BCP materials.

      Release date:2021-01-29 03:56 Export PDF Favorites Scan
    • Effect of sinus diameter on the opening and closing performance of aortic valve under the expansion of aortic root

      This study aims to explore the effect of aortic sinus diameter on aortic valve opening and closing performance in the case of no obvious disease of aortic valve and annulus and continuous dilation of aortic root. A total of 25 three-dimensional aortic root models with different aortic sinus and root diameters were constructed according to the size of clinical surgical guidance. The valve sinus diameter DS is set to 32, 36, 40, 44 and 48 mm, respectively, and the aortic root diameter DA is set to 26, 27, 28, 29 and 30 mm, respectively. Through the structural mechanics calculation with the finite element software, the maximum stress, valve orifice area, contact force and other parameters of the model are analyzed to evaluate the valve opening and closing performance under the dilated state. The study found that aortic valve stenosis occurs when the DS = 32 mm, DA = 26, 27 mm and DS = 36 mm, DA = 26 mm. Aortic regurgitation occurs when the DS = 32, 36 and 40 mm, DA = 30 mm and DS = 44, 48 mm, DA = 29, 30 mm. The other 15 models had normal valve movement. The results showed that the size of the aortic sinus affected the opening and closing performance of the aortic valve. The smaller sinus diameter adapted with the larger root diameter and the larger sinus diameter adapted with the smaller root diameter. When the sinus diameter is 40 mm, the mechanical performance of the valve are good and it can well adapt with the relatively large range of aortic root dilation.

      Release date:2019-12-17 10:44 Export PDF Favorites Scan
    3 pages Previous 1 2 3 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南