• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "avulsion fracture" 27 results
    • Effectiveness of multidirectionally three-dimensional steel wire ring sleeve fixation in treatment of inferior patellar pole avulsion fractures

      ObjectiveTo explore the method and effectiveness of multidirectionally three-dimensional steel wire ring sleeve fixation in the treatment of inferior patellar pole avulsion fractures.MethodsBetweern January 2015 and January 2019, 22 patients with inferior patellar pole avulsion fractures were admitted and treated. There were 12 males and 10 females. The age ranged from 20 to 69 years, with an average age of 39.4 years. The causes of injury included 9 cases of traffic accident and 13 cases of falling. All of them were unilateral closed injury of knee joint, including 7 cases of skin contusion around patella. Preoperative range of motion of the affected knee was (20.82±7.16)° (range, 10°-35°). The time from injury to operation ranged from 3 to 12 days, with an average of 5.9 days. During the operation, the inferior patellar avulsion fracture was reduced with forceps; the patella was circumferentially ligated through the distal bone surface of the fracture with 0.8 mm diameter steel wire; then 3 longitudinal bone tunnels were made in the upper patella, respectively. The 0.8 mm diameter steel wire passed through the bone tunnel, and the longitudinal ring was attached to the ring to fix the upper and inferior patellar fracture. Tighten the transverse and longitudinal rings with No.2 tendon suture line, then longitudinally ringed and sutured to strengthen the patella. The knee range of motion, fracture healing time, and complications were recorded. The functional recovery of the knee joint was evaluated by B?stman score.ResultsAll incisions healed by first intention, and no incision related complications occurred. All the 22 patients were followed up 13 months to 5 years with an average of 26.7 months. The fracture healing time was 9-12 weeks (mean, 10.9 weeks). At last follow-up, the knee range of motion was (129.77±2.35)° (range, 126°-135°), showing significant difference when compared with preoperative one (t=?67.022, P=0.000). The B?stman score ranged from 31 to 36, with an average of 34.3. No reduction loss, fracture of steel wire, failure of internal fixation, and other complications occurred during follow-up.ConclusionMultidirectionally three-dimensional steel wire ring sleeve fixation in the treatment of inferior patellar pole avulsion fractures has the advantages of reliable fixation, early functional recovery, and fewer complications, so the effectiveness is satisfactory.

      Release date:2021-02-24 05:33 Export PDF Favorites Scan
    • EFFECTIVENESS OF ARTHROSCOPIC TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE WITH NON-ABSORBABLE SUTURE FIXATION COMBINED WITH MINI-PLATE

      Objective To evaluate the surgical techniques and effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture with non-absorbable suture fixation combined with the mini-plate. Methods Between January 2009 and March 2012, 32 patients with ACL tibial eminence avulsion fractures were treated. There were 18 males and 14 females, aged 12-40 years (mean, 17.5 years). The injury causes included traffic accident injury in 15 cases, sport injury in 6 cases, and falling injury in 11 cases. The time from injury to operation ranged 7-18 days with an average of 9.5 days. Before operation, the results of Lachman test were all positive; the Lysholm score was 52.13 ± 4.22 and the International Knee Documentation Committee (IKDC) score was 44.82 ± 2.44. According to Meyers-McKeever classification criteria, there were 12 cases of type II and 20 cases of type III. After arthroscopic poking reduction of fracture, tibial eminence avulsion fractures were fixed with the Ethibond non-absorbable sutures bypass figure-of-eight tibial tunnel combined with the metacarpal and phalangeal mini-plate. Results Primary healing was obtained in all incisions; no joint infection or skin necrosis occurred after operation. All patients were followed up with an average time of 22.4 months (range, 12-50 months). The patients showed negative Lachman test at 12 weeks after operation. Except 3 patients having knee extension limitation at last follow-up, the knee extension range of motion (ROM) was normal in the other patients; the knee flexion ROM was normal in all patients. The Lysholm score and IKDC score were significantly improved to 94.19 ± 0.93 and 94.35 ± 1.22 at last follow-up, showing significant differences when compared with preoperative values (t=55.080, P=0.000; t=101.715, P=0.000). Conclusion The arthroscopic treatment of ACL tibial eminence avulsion fracture with Ethibond non-absorbable suture fixation combined with mini-plate is an effective procedure with the advantages of minimal trauma, reliable fixation, and satisfactory recovery of the knee joint function.

      Release date:2016-08-31 04:12 Export PDF Favorites Scan
    • EFFECTIVENESS COMPARISON OF TWO ARTHROSCOPIC DIFFERENT FIXATIONS FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURES

      Objective To compare the effectiveness of arthroscopic screw and suture fixations in treatment of anterior cruciate ligament tibial eminence avulsion fractures. Methods Between January 2002 and January 2009, 43 patients with freshanterior cruciate ligament tibial eminence avulsion fracture were treated, which were rated as types II and III according to Meyers- McKeever-Zaricznyj classification. Fractures were fixed with either screw (screw group, n=21) or nonabsorbable suture (suture group, n=22). There was no significant difference in sex, age, disease duration, and fracture type between 2 groups (P gt; 0.05). The range of motion (ROM) and Lysholm score were compared between 2 groups, and the knee stabil ity was evaluated based on the Lachman test and KT-2000 measurement. Results The operation time was 48-60 minutes (mean, 51.6 minutes) in the screw group, and 55-68 minutes (mean, 63.2 minutes) in the suture group, showing significant difference (t=4.645, P=0.032). Incisions healed by first intention and no compl ication occurred in 2 groups. All patients were followed up (5.7 ± 0.6) years in the screw group and (5.3 ± 0.5) years in the suture group. The fracture healed completely in both groups; the heal ing time was (3.3 ± 0.6) months in the screw group and (3.2 ± 0.4) months in the suture group, showing significant difference (t=3.723, P=0.019). Between the screw group and the suture group, no significant difference was found in ROM [(128.6 ± 10.1)° vs. (130.2 ± 14.1)°, P gt; 0.05] and Lysholm score (94.6 ± 14.5 vs. 95.1 ± 17.2, P gt; 0.05). The stabil ities based on KT-2000 measurement were also similar between 2 groups at last follow-up [(0.9 ± 0.3) mm vs. (1.0 ± 0.4) mm, P gt; 0.05]. Lachman test of 2 groups were negative. Conclusion Boththe screw and nonabsorbable suture fixation techniques for anterior cruciate l igament tibial eminence avulsion fracture (type II or III) have good results in terms of functional outcome and stabil ity. However, some patients show flexion contractures of 5° or 10°.

      Release date:2016-08-31 05:44 Export PDF Favorites Scan
    • EFFECTIVENESS OF ARTHROSCOPIC ULTRA-Braid SUTURE PLANE FIXATION FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURES

      ObjectiveTo investigate the surgical technique and effectiveness of arthroscopic ULTRA-Braid suture plane fixation for anterior cruciate ligament (ACL) tibial eminence avulsion fractures. MethodsBetween June 2012 and October 2014, 16 cases of ACL tibial eminence avulsion fracture were treated with ULTRA-Braid suture plane fixation under arthroscopy. There were 10 males and 6 females, aged from 17 to 38 years (mean, 25.8 years). The left knee was involved in 5 cases and the right knee in 11 cases. The causes were traffic accident injury in 9 cases, falling from height injury in 4 cases, and sports injury in 3 cases. The average interval from injury to operation was 7 days (range, 5-10 days) except 1 patient who received operation at 6 weeks after injury. The knee joint swelling was obvious; the result of Lachman test was positive; and the knee joint Lysholm score was 45.38±9.87. According to classification standard introduced by Meyers-McKeever-Zaricznyj, 7 cases were rated as type Ⅱ, 8 cases as type Ⅲ, and 1 case as type Ⅳ, excluding ligament and meniscus injury. ResultsAll the incisions healed by first intention. The patients received follow-up of 6-18 months (mean, 10 months). The postoperative X-ray and CT showed anatomic reduction (12 cases) or near anatomic reduction (4 cases); all fractures healed at 6 months after operation. The result of Lachman test was negative in the other 15 patients except 1 patient (Ⅱ degree). One patient had slight knee pain at 6 months postoperatively, and pain symptom disappeared after 1 year; the other cases resumed daily activities. Lysholm score at last follow-up was 98.13±2.34, showing significant difference when compared with preoperative score (t=-20.801, P=0.000). ConclusionArthroscopic ULTRA-Braid suture plane fixation for ACL tibial eminence avulsion fractures is an effective procedure with the advantages of minimal trauma, reliable fixation, satisfactory functional recovery, and simultaneously avoiding the second surgery.

      Release date: Export PDF Favorites Scan
    • Arthroscopic treatment of anterior cruciate ligament tibial eminence avulsion fracture with double heads compressive cannulated screw fixation in adolescents

      ObjectiveTo discuss the effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture in adolescents by using double heads compressive cannulated screw fixation.MethodsTwenty-four patients with ACL tibial eminence avulsion fractures were treated by arthroscopic reduction and internal fixation with double heads compressive cannulated screw fixation between June 2014 and June 2017. There were 15 males and 9 females with an average age of 12.3 years (range, 5-18 years). The body mass index was 19.3-26.4 kg/m2 (mean, 23.3 kg/m2). The injury causes included traffic accident injury in 10 cases, sports injury in 8 cases, and falling injury in 6 cases. According to the Meyers-McKeever classification, there were 19 cases of type Ⅱ and 5 cases of type Ⅲa. All patients’ drawer test and pivot shift test were positive. The interval between injury and operation was 3-14 days (mean, 6.2 days). During the follow-up period, the fracture healing condition of patients were determined by X-ray examination; Lysholm score, International Knee literature Committee (IKDC) score, and Tegner score were used to evaluate the knee function.ResultsPrimary healing of incision was obtained in all patients after operation. All the 24 patients were followed up 6-32 months (mean, 16.4 months). At 6 weeks after operation, 3 patients had difficulty in knee flexion. After the release of the knee joint by manipulation, the knee joint function recovered normally at 6 months after operation. At last follow-up, the X-ray films showed that all the fractures healed and no epiphyseal dysplasia, knee joint deformity, or leg length discrepancy occurred. The Lysholm score, IKDC score, and Tegner score were improved from preoperative 44.3±5.4, 43.7±4.4, and 3.0±1.3 to postoperative 93.1±4.3, 94.6±3.3, and 8.1±1.2, the differences were all significant (t=25.152, P=0.000; t=28.634, P=0.000; t=13.226, P=0.000).ConclusionThe arthroscopic reduction and internal fixation with double heads compressive cannulated screw in treatment of ACL tibial avulsion fracture (Meyers-McKeever type Ⅱ and Ⅲ) in adolescents has so many advantages, such as minimal trauma, simple operation, firm fixation, little effect on the epiphyseal plate, and has a good joint function recovery.

      Release date:2018-09-03 10:13 Export PDF Favorites Scan
    • ARTHROSCOPICALLY ASSISTED TREATMENT OF ACUTE TIBIAL INSERTION AVULSION FRACTURE OF POSTERIOR CRUCIATE LIGAMENT VIA POSTEROMEDIAL INCISION

      Objective To investigate the effectiveness of arthroscopically assisted treatment of acute tibial insertion avulsion fracture of the posterior cruciate ligament (PCL) via posteromedial incision. Methods Between January 2010 and January 2012, 22 patients with acute tibial insertion avulsion of the PCL underwent arthroscopic reduction and fixation via posteromedial incision. There were 14 males and 8 females with an average age of 32 years (range, 18-48 years). The injury causes included traffic accident injury in 14 cases, sport injury in 4 cases, and falling injury in 4 cases. The disease duration ranged from 7 to 16 days (mean, 10 days). Of 22 patient, 14 had simple PCL injury, 6 had PCL injury with meniscus injury, and 2 with cartilage injury. The results of posterior drawer test were positive in all patients. The preoperative Lysholm score was 51.1 ± 3.4. Results All incisions healed by first intention without infection, deep venous thrombosis of lower limbs, or vessel and nerve injuries. All patients were followed up 12-24 months (mean, 18.4 months). X-ray films showed that all fractures healed with the healing time of 2-4 months (mean, 3 months). The Lysholm score was improved to 96.0 ± 2.2 at 6 months after operation, showing significant difference when compared with preoperative score (t=43.020, P=0.000). Conclusion Arthroscopically assisted treatment of acute tibial insertion avulsion fracture of the PCL via posteromedial incision is a safe, easy, and effective method.

      Release date:2016-08-31 04:07 Export PDF Favorites Scan
    • Study on development and biomechanics test of plastic rod-hook plate

      ObjectiveTo develop a new type of internal fixation device which can be used to treat the minor avulsion fracture of the medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process, and investigate the reliability and effectiveness of the device through biomechanical test.MethodsEighty human’s bone specimens with complete medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process were selected and measured the anatomic indexes (the height, width, and thickness of medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process). The CT three-dimensional reconstruction data of 200 healthy adults which including medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process was also selected and measured the anatomic indexes by Mimics software. The plastic rod-hook plate was designed according to the measured results and prepared. Forty fresh porcine lower limb specimens were randomly divided into groups A and B (20 in each group), and 8 adult lower limb specimens including 4 left and 4 right were also randomly divided into groups A and B (4 in each group). All specimens were prepared for avulsion fracture of medial malleolus. Then, the fractures were fixed with plastic rod-hook plate in group A and wire anchor in group B. The load and axial torsion test of ankle joint were carried out by universal biomechanical testing machine.ResultsAccording to the anatomical characteristics, a plastic rod-hook plate was designed successfully. The biomechanical test results between animal and human specimens were consistent. There was a linear relationship between load and displacement in the ankle distal load test. The displacement when loaded to the maximum load was significantly lower in group A than in group B (P<0.05). The torsion angle and torque were significantly higher in group A than in group B when the internal fixation failed in the axial torsion test of the ankle joint (P<0.05), and the torsion angle was significantly smaller in group A than in group B when the torque was 1 N·m (P<0.05), and the maximum torque was also significantly higher in group A than in group B (P<0.05). However, there was no significant difference in torsion angle between the two groups in the maximum torque (P>0.05).ConclusionThe biomechanical properties of plastic rod-hook plate is obviously better than wire anchor, and the fixation of avulsion fracture with plastic rod-hook plate is easy to operate, which is expected to be used in the clinical treatment of minor avulsion fractures such as medial malleolus, lateral malleolus, base of the fifth metatarsal, and ulna styloid process.

      Release date:2019-11-21 03:35 Export PDF Favorites Scan
    • ARTHROSCOPIC TREATMENT FOR TIBIAL EMINENCE AVULSION FRACTURE USING ABSORBABLE DOUBLE SUTURE ANCHORS

      Objective To investigate the outcomes of arthroscopic reduction and internal fixation of tibial eminence avulsion fracture using absorbable double suture anchors. Methods Between February 2007 and August 2009, 18 patients with tibial eminence avulsion fracture were treated with arthroscopic reduction and fixation using absorbable doublensuture anchors. There were 12 males and 6 females with an average age of 30.6 years (range, 17-48 years). The disease causes were traffic accident injury in 4 cases, sport injury in 8 cases, and fall ing from height injury in 6 cases; the locations were left side in 7 cases and right side in 11 cases. The results of the anterior drawer test and Lachman test were positive. According to Meyers-McKeever classification, 10 cases were rated as type II, 7 as type III, and 1 as type IV fractures. The time from injury to treatment was 6-20 days (mean, 10.2 days). Results Incision healed primarily. All the patients were followed up 29.1 months (range, 13-43 months). The X-ray films showed good reduction of fracture immediately after operation and fracture heal ing at 3 months. At the last follow-up, the range of motion of knee was 0-130°. The results of Lachman test and anterior drawer test were negative in 18 cases and 16 cases, repectively; and the results of anterior drawer test were weakly positive in 2 cases. The mean Lysholm score was significantly improved from 53.9 ± 6.7 preoperatively to 91.6 ± 4.2 postoperatively (t=22.100, P=0.000). The Inter national knee Documentation Commitee (IKDC) 2000 subject score improved from 58.1 ± 3.7 preoperatively to 92.8 ± 5.9 postoperatively (t=20.700, P=0.000). Conclusion Arthroscopic treatment using absorbable double suture anchors for tibial eminence avulsion fracture can provide satisfactory reduction, stable fixation, and good heal ing of the avulsed fragment, which is a minimally-invasive, simple, and effective treatment for patients with tibial eminence avulsion fracture.

      Release date:2016-08-31 05:42 Export PDF Favorites Scan
    • EFFECTIVENESS OF MINI INCISION AND ABSORBABLE SCREW FIXATION FOR TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE

      ObjectiveTo investigate the effectiveness of open reduction by mini incision and absorbable screw internal fixation for the treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture. MethodsBetween January 2006 and July 2012, 90 patients (90 knees) with ACL tibial eminence avulsion fracture were treated. There were 58 males and 32 females, aged from 10 to 58 years with an average of 33.7 years. The causes of injury were traffic accident injury in 60 cases, sports injury in 22 cases, and falling injury in 8 cases. The disease duration was 1-365 days with a median of 106 days. Combined injuries included 14 cases of meniscus injury, 5 cases of medial collateral ligament injury, and 3 cases of avulsion fracture of the anterior horn of the lateral meniscus. All patients underwent open reduction by mini incision and internal fixation with absorbable screw. Postoperative rehabilitation exercise was performed. ResultsTwo patients had delayed healing of incision, and others obtained primary healing. All the patients were followed up 6-72 months (mean, 40.1 months). X-ray examination showed that bone union was achieved in all patients at 3-12 months after operation; nail tail came off in 7 cases at 4-13 months after operation, and the nail tail was taken out under arthroscopy. At 6-12 months after operation, the range of motion (ROM), Tegner score, Lysholm score, and International Knee Documentation Committee (IKDC) score were significantly increased when compared with preoperative ones (P < 0.05). ConclusionA combination of open reduction by mini incision and absorbable screw internal fixation for the treatment of ACL tibial eminence avulsion fracture has the advantages of easy operation, firm fixation, and satisfactory functional rehabilitation, so it is a safe and effective method for the treatment of ACL tibial eminence avulsion fracture.

      Release date: Export PDF Favorites Scan
    • ARTHROSCOPICALLY ASSISTED TREATMENT OF POSTERIOR CRUCIATE LIGAMENT AVULSION FRACTURE WITH MENISCUS POSTERIOR HORN TEAR

      ObjectiveTo evaluate the effectiveness of arthroscopically assisted treatment of posterior cruciate ligament (PCL) tibial eminence avulsion fractures associated with meniscus posterior horn tear. MethodsBetween January 2012 and December 2014, 21 patients with PCL avulsion fracture and meniscus posterior horn tear were arthroscopically treated with polyester suture and hollow screw fixation. There were 10 males (10 knees) and 11 females (11 knees), aged 14-53 years (mean, 35.7 years). The causes included sport injury in 11 cases, traffic accident injury in 9 cases, and daily life injury in 1 case. Based on the anteroposterior and lateral X-ray films, CT, and MRI, PCL avulsion fractures were diagnosed, and 2 cases had anterior cruciate ligament avulsion fractures. The results of posterior drawer test were positive in all patients, with no end point in 14 cases and with soft end point in 7 cases; all patients showed tibial sink. The preoperative International Knee Documentation Committee (IKDC) score and Lysholm score were 46.5±5.5 and 43.3±4.5 respectively. The time from injury to operation was 6-22 days (mean, 10 days). ResultsThe operation time was 60-100 minutes (mean, 75 minutes). Primary healing of incision was obtained in all patients, without no complication of infection. The mean follow-up time was 27.4 months (range, 12-46 months). The results of posterior drawer test were negative in 19 cases, and positive in 2 cases (having hard end point). Tibial sink disappeared. At last follow-up, X-ray film showed good healing of fracture, and no displacement. The patients had no locking knee, snapping or tenderness of joint space, and the Mcmurray sign was negative; the IKDC score and Lysholm score were significantly improved to 92.0±2.5 and 92.7±2.6 respectively (t=-39.903, P=0.000; t=-43.242, P=0.000). The range of motion was normal in 20 patients (0-130°) except 1 patient having limited flexion (0-80°), whose range of motion returned to 0-120° after release. ConclusionThe arthroscopic fixation technique has satisfactory results for the reduction and fixation of PCL avulsion fracture associated with meniscus posterior horn tear because of easy operation, firm fixation, and economic price.

      Release date:2016-10-21 06:36 Export PDF Favorites Scan
    3 pages Previous 1 2 3 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南