• <table id="gigg0"></table>
  • west china medical publishers
    Author
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Author "ZHONG Gang" 18 results
    • CLINICAL RESEARCH PROGRESS OF HETEROTOPIC OSSIFICATION OF ELBOW AFTER INJURY

      Objective To review the basic research and cl inical progress of elbow heterotopic ossification after injury. Methods The recent l iterature concerning heterotopic ossification of the elbow was reviewed. Results Heterotopic ossification was caused by variety of stimul i and conditions. The current methods of prevention and treatment were to improve surgical techniques, to reduce trauma and bleeding, to rinse the area with bone fragments with plenty of salt water, and to use non-steroidal anti-inflammatory drugs. Conclusion Once heterotopic ossification occurred, surgical treatment is unique treatment method, so emphasis is to prevent heterotopic ossification.

      Release date:2016-09-01 09:03 Export PDF Favorites Scan
    • Artificial Humeral Head Replacement in the Treatment of Fractures of the Proximal Humerus

      目的:回顧性研究人工肱骨頭置換治療復雜肱骨近端骨折患者的肩關節的情況,以進一步提高療效。方法:對我院2004年至2007年27例肱骨近端骨折患者采用肱骨頭置換術治療,術中修復關節囊和肩袖,術后隨訪5~38月,評價其肩關節功能。結果:采用半關節成形改良評分系統SSMH綜合評分,優:5例,良:17例,可:5例,優良率:815%。肩關節活動:平均前屈上舉:96°,外旋:36°,內旋至L2水平。X片示假體無松動斷裂,位置良好。結論:對于復雜的肱骨近端骨折,人工肱骨頭置換是有效治療手段,能夠最大限度恢復期肩關節活動功能。

      Release date:2016-09-08 09:56 Export PDF Favorites Scan
    • RESEARCH PROGRESS IN REPAIR AND RECONSTRUCTION OF ISOLATED TRAUMATIC RADIAL HEAD DISLOCATION WITH ANNULAR LIGAMENT INJURY IN CHILDREN

      Objective To review the research progress in the repair and reconstruction of isolated traumatic radial head dislocation with annular l igament injury in children. Methods In recent years, the related l iterature concering isolated traumatic radial head dislocation with annular l igament injury in children was reviewed. Results For isolated traumatic radial head dislocation with annular l igament injury in children, the surgery should be chosen as the main treatment, includingopen reduction and annular l igament reconstruction surgery. Triceps aponeurosis is usually used as reconstruction materials of annular l igament, mainly because the position of taking material of annular l igament is at the operative incision with less surgery trauma and short operative time; aponeurosis is tough and thick with rigid fixation and low risk of re-dislocation. Artificial materials are paid attention to increasingly because they are easy to get, have rigid fixation, and can avoid operative injury caused by taking material of annular l igament. Conclusion Currently active annular l igament reconstruction surgery should be taken; triceps aponeurosis is widely adopted as reconstruction materials of annular l igament and artificial materials have come to be a new research trend.

      Release date:2016-08-31 05:42 Export PDF Favorites Scan
    • Application of skin stretcher for repair of postoperative skin and soft tissue defects in tibial fractures

      ObjectiveTo discuss the efficacy of skin stretcher applied for repair of postoperative skin and soft tissue defects in tibial fractures.MethodsBetween April 2016 and March 2017, 15 cases with skin and soft tissue defects after tibial fractures fixation were treated with the skin stretcher. There were 11 males and 4 females with an age of 24-59 years (mean, 37.5 years). The causes of injury included traffic accident in 7 cases, bruise in 3 cases, falling from height in 3 cases, and falling in 2 cases; without nerve and vascular injury in all patients. These cases were followed up 1-3 months after their first surgery, consisting of 3 closed fractures treated with open reduction and plate and screw fixation, 12 open fractures treated with external fixation after debridement. The area of skin defects ranged from 14 cm×5 cm to 20 cm×7 cm, all of which were stripped or spindle shaped skin defects. First, the skin was penetrated by two Kirschner wires which were locked by skin stretchers on both sides of the skin defect longitudinally. Then, the tension of skin stretchers was timely adjusted according to the skin flap blood supply and muscle compression. Finally, Kirschner wires and skin stretchers were removed when the edge of skin contacted and been sutured.ResultsAll skin and soft tissue defects were covered after stretching for 6-13 days. The interrupted sutured wounds healed at 12 days. Clinical scores of wound healing decreased from 3.40±0.51 at immediate postoperatively to 1.27±0.46 at 12 days postoperatively, showing significant difference (t=12.911, P=0.000). All the patients were followed up 4-12 months (mean, 6.5 months). After stretching, the skin color, elasticity, and pain and touch feeling were similar with the normal skin, and the hair growth was normal. After operation, 1 case of nail tract infection and 2 cases of calf discomfort occurred, and all were relieved after treatment.ConclusionIt is an effective method for repairing postoperative skin and soft tissue defects in tibial fractures with the application of skin stretchers.

      Release date:2018-05-02 02:41 Export PDF Favorites Scan
    • Treatment of peri-implant refracture after intramedullary nail fixation for intertrochanteric fractures

      ObjectiveTo investigate the occurrence, treatment, and effectiveness of peri-implant refracture after intramedullary nail fixation for intertrochanteric fractures.MethodsThe clinical data of 16 patients with peri-implant refracture after intramedullary nail fixation for intertrochanteric fractures who met the inclusion criteria between April 2014 and November 2019 were retrospectively analyzed. There were 7 males and 9 females with an average age of 78.4 years (range, 65-93 years). The 14 cases of initial intertrochanteric fractures were classified according to the classification of AO/Orthopaedic Trauma Association (AO/OTA): 5 cases of type A1, 7 cases of type A2, and 2 cases of type A3; the other 2 cases were intertrochanteric combined with subtrochanteric fractures (Seinsheimer type Ⅴ). According to the classification of peri-implant refracture which was proposed by Chan et al., there were 10 cases of type 1 (6 cases of type 1A, 3 cases of type 1B, 1 case of type 1C) and 6 cases of type 2 (4 cases of type 2A and 2 cases of type 2B). The average interval between refracture and initial surgery was 14.6 months (range, 1-52 months). The incidence of peri-implant refracture in short nail group (the length of intramedullary nail used in initial surgery≤240 mm) was 1.92% (11/573), while the incidence of long nail group (the length of intramedullary nail used in initial surgery≥340 mm) was 1.66% (5/301), showing no significant difference between the two groups (χ2=0.073, P=0.786). The peri-implant refractures were revised with extended intramedullary nail (5 cases) or fixed with additional limited invasive stabilization system (11 cases).ResultsThe average operation time was 115.8 minutes (range, 78-168 minutes) and the average intraoperative blood loss was 283.1 mL (range, 120-500 mL). One patient died of myocardial infarction at 3 months after operation, and the other 15 patients were followed up 9-46 months (mean, 16.8 months). The peri-implant refractures healed at 14-20 weeks (mean, 16.4 weeks) after operation. There was no complications such as incision infection, nonunion, internal fixator loosening and rupture, screw cutting-out, and the second refracture during the follow-up. At last follow-up, all injured limbs regained walking function, and the Hospital for Special Surgery (HSS) score was 56-92 (mean, 80.2). The results were classified as excellent in 2 cases, good in 10, fair in 2, and poor in 1, with the excellent and good rate of 80%.ConclusionStress concentration at the tip of initial intramedullary nail and distal interlocking screw aera is the main cause of peri-implant refracture after intramedullary nail fixation for intertrochanteric fractures. Revision with extended intramedullary nail or fixation with limited invasive stabilization system according to the length of initial intramedullary nail and the type of refracture can get satisfactory effectiveness.

      Release date:2021-03-26 07:36 Export PDF Favorites Scan
    • DESIGN OF INSTRUMENTS FOR MENISCAL SUTURE WITH TENDON

      To design a new suit of instruments for meniscal suture with tondon, and then authenticate their feasibil ity and the therapeutic effect of the new technique. Methods Instruments were developed, including new ones and others which was improved according to the current instruments. From October 2005 to December 2006, 45 patients with meniscal injury were treated by meniscal suture with tendon. There were 29 males and 16 females, aged 17-40 years (mean 28 years). Injury was caused by sports in 33 cases, by traffic accident in 5 cases, by fall ing in 3 case and others in 4 cases. The disease course was 3 days to 6 months (mean 2 months). There were 23 cases accompanying with anterior cruciate l igament injury and 6 cases accompanying with posterior cruciate l igament injury. E-MRI showed 2 cases of degree II and 43 cases of degree III. Arthroscope showed that injury was at medial meniscus in 39 cases and at lateral meniscus in 6 cases. The pre-operationalLysholm score was 53.0 ± 10.3. Autogeneic or xenogenic tendon was made into suture l ine guided by stitch at the two ends. Thetherapeutic effect of the new technique was authenticated by cl inical results, including the change of symptoms and phy sical signs, and by comparing the pre-operational Lysholm score with the post one. Results Nineteen pieces of instruments weredeveloped. All the operation were successful, with no harm to nerves and vessels. The follow-up was 6 months to 24 mo nths (mean15 months). At the last follow-up, all the symptoms disappeared, including pain, swell ing and locking, etc. The Lysholm sc oreafter 6 months of operation was 87.8 ± 9.2, showing statistically significant difference when compared with per-operati on ( P lt; 0.01). Conclusion It is feasible to suture injured menisci with the new instruments and technique. It is an effective way to repair menisci with tendon according to the short-term results.

      Release date:2016-09-01 09:14 Export PDF Favorites Scan
    • TREATMENT OF PROXIMAL ULNA AND OLECRANON FRACTURES BY RECONSTRUCTION PLATE COMBINED WITH TENSION BAND WIRING

      Objective To review the efficacy of reconstruction plate combined with tension band wiring for treating proximal ulna and olecranon fractures. Methods Between November 2004 and September 2009, 10 patients with proximal ulna and olecranon fractures were treated by reconstruction plate combined with tension band wiring. There were 6 males and4 females with an average age of 45.3 years (range, 21-75 years). Five fractures were caused by traffic accident, 2 by fall ing from height, 2 by tumbl ing, and 1 by a machine strangulation. The locations were the left side and the right side in 5 cases respectively. One case was open fracture (Gustilo II) and the other 9 were closed fractures. Olecranon fractures included 4 cases of traverse fractures and 6 cases of comminuted fractures, and proximal ulna fractures included 6 cases of comminuted fractures and 4 cases of obl ique fractures. The combined fractures included 6 radial head fractures, 4 coronoid process fractures, 2 proximal humerus fractures, and 3 scapula fractures; other injury included 1 elbow dislocation and 1 shoulder dislocation. Two patients had secondary operation; the other 8 patients received the primary operations and the time from injury to operation varied from 7 days to 20 days, with an average of 11 days. Results One case had infection at the incision 1 week after operation, and recovered after 2 months of antibiotics and debridement; incisions healed by first intention in other 9 patients. All patients were followed up 12-64 months (mean, 40.5 months). The X-ray films showed that fracture heal ing was achieved at 10-24 weeks (mean, 12 weeks). There was no ulnar nerve symptom in all cases. Heterotopic ossification occurred in 1 case at 2 months and stiffness of the elbow in 1 case at 3 months after operation; they were both cured after symptomatic treatment. Proximal migration of Kirschner wires was found in 1 case at 6 months after operation, whose implants were taken out at 9 months after the first operation because fracture had healed. At last follow-up, the flexion and extension arc of the elbow averaged 92.8°(range, 23-130°), and the arc of forearm rotation averaged 124.4° (range, 42-175°). According to the American Hospital for Special Surgery (HSS) evaluation method, the results were classified as excellent in 6 cases, good in 2, fair in 1, and poor in 1. Conclusion Treating proximal ulna and olecranon fractures by reconstruction plate combined with tension band wiring allows patients to do postoperative exercise early and could effectively avoid compl ications.

      Release date:2016-08-31 05:41 Export PDF Favorites Scan
    • Treatment of the SubAcute and Old Scaphoid Fracture by Internal Fixation with Herbert Screws and Orthopedic External Fixation Support

      【摘要】 目的 評價切開復位Herbert螺釘內固定加外支架治療對亞急性和陳舊性舟狀骨骨折的治療效果。方法 2008年2月—2009年5月,對15例受傷后4周以上(平均7.6周)入院診斷為亞急性和陳舊性舟狀骨骨折的患者均采用Herbert螺釘內固定加外支架治療,術后隨訪5~16個月,平均12.5個月,按Gartland amp; Werley和改良Green amp; O’Brein評分系統進行評價治療效果。結果 15例患者均進行有效隨訪,末次隨訪Gartland amp; Werley評分優8例,良5例,中2例,優良率為86.7%,改良Green amp; O’Brein評分優7例,良5例,中3例,優良率為80%。結論 此方法是治療亞急性和陳舊性舟狀骨骨折的有效措施,值得推廣。

      Release date:2016-09-08 09:37 Export PDF Favorites Scan
    • BIOMECHANICAL STUDY ON PROXIMALLY BASED CONJOINED TENDON TRANSFER FOR CORACOACROMIAL LIGAMENT RECONSTRUCTION AS ANTEROSUPERIOR RESTRAINT OF SHOULDER JOINT

      Objective To simulate anterosuperior instabil ity of the shoulder by a combination of massive irreparable rotator cuff tears and coracoacromial arch disruption in cadaveric specimens, use proximally based conjoined tendon transfer forcoracoacromial l igament (CAL) reconstruction to restrain against superior humeral subluxation, and investigate its feasibility and biomechanics property. Methods Nine donated male-adult and fresh-frozen cadaveric glenohumeral joints were applied to mimic a massive irreparable rotator cuff tear in each shoulder. The integrity of the rotator cuff tendons and morphology of the CAL were visually inspected in the course of specimen preparation. Cal ipers were used to measure the length of the CAL’s length of the medial and the lateral bands, the width of coracoid process and the acromion attachment, and the thickness in the middle, as well as the length, width and thickness of the conjoined tendon and the lateral half of the removed conjoined tendon. The glenohumeral joints were positioned in a combination of 30° extension, 0° abduction and 30° external rotation. The value of anterosuperior humeral head translation was measured after the appl ication of a 50 N axial compressive load to the humeral shaft under 4 sequential scenarios: intact CAL, subperiosteal CAL release, CAL anatomic reattachment, entire CAL excision after lateral half of the proximally based conjoined tendon transfer for CAL reconstruction. Results All specimens had an intact rotator cuff on gross inspection. CAL morphology revealed 1 Y-shaped, 4 quadrangular, and 4 broad l igaments. The length of the medial and lateral bands of the CAL was (28.91 ± 5.56) mm and (31.90 ± 4.21) mm, respectively; the width of coracoid process and acromion attachment of the CAL was (26.80 ± 10.24) mm and (15.86 ± 2.28) mm, respectively; and the thickness of middle part of the CAL was (1.61 ± 0.36) mm. The length, width, and thickness of the proximal part of the proximally based conjoined tendon was (84.91 ± 9.42), (19.74 ± 1.77), and (2.09 ± 0.45) mm, respectively. The length and width of the removed lateral half of the proximally conjoined tendon was (42.67 ± 3.10) mm and (9.89 ± 0.93) mm, respectively. The anterosuperior humeral head translation was intact CAL (8.13 ± 1.99) mm, subperiosteal CAL release (9.68 ± 1.97) mm, CAL anatomic reattachment (8.57 ± 1.97) mm, and the lateral half of the proximally conjoined tendon transfer for CAL reconstruction (8.59 ± 2.06) mm. A significant increase in anterosuperior migration was found after subperiosteal CAL release was compared with intact CAL (P lt; 0.05). The translation after CAL anatomic reattachment and lateral half of the proximally conjoined tendon transfer for CAL reconstruction increased over intact CAL, though no significance was found (P gt; 0.05); when they were compared with subperiosteal CAL release, the migration decreased significantly (P lt; 0.05). The translation of lateral half of the proximally conjoined tendon transfer for CAL reconstruction increased over CAL anatomic reattachment, but no significance was evident (P gt; 0.05). Conclusion The CAL should be preserved or reconstructed as far as possible during subacromial decompression, rotator cuff tears repair, and hemiarthroplasty for patients with massive rotator cuff deficiency. If preservation or the insertion reattachment after subperiosteal release from acromion of the CAL of the CAL is impossible, or CAL is entirely resected becauseof previous operation, the use of the lateral half of the proximally based conjoined tendon transfer for CAL reconstruction isfeasible.

      Release date:2016-09-01 09:08 Export PDF Favorites Scan
    • CLINICAL RESULTS OF OPEN ARTHROLYSIS BY ELEVATED LATERAL AND MEDIAL COLLATERAL LIGAMENT-MUSCULATURE COMPLEX FROM SUPRACONDYLAR RIDGE OF HUMERUS IN TREATMENT OF POST-TRAUMATIC ELBOW STIFFNESS

      Objective To evaluate the results of open arthrolysis by elevated the lateral and medial collateral l igament-musculature complex from the supracondylar ridge of the humerus in treatment of post-traumatic elbow stiffness. Methods From March 2003 to December 2007, 33 patients with post-traumatic elbow stiffness were treated with open arthrolysis by elevated the lateral and medial collateral l igament-musculature complex from the supracondylar ridge of the humerus. There were 23 males and 10 females, aged 17-70 years old (mean 41.8 years old). According to Morrey, 15 caseswere extremely serious (less than 30° extension-flexion arc) and 18 cases were serious (30-60° extension-flexion arc). The range of motion of the elbow stiffness was (32.5 ± 28.9)° and the Mayo score was 51.9±13.1 before operation. All initial fractures were healed according to cl inical examination and X-rays films. All patients present with a post-traumatic elbow stiffness and the average period from initial trauma to elbow arthrolysis was 16.9 months (2-72 months). Results Wound infection occurred in 1 patient and cured after dressing change and anti-infectious treatment. The wounds healed by first intension in 32 cases. No patient showed sign of elbow instabil ity and debil itating pain. All patients were followed up 6 months to 5 years (mean 3.3 years). At last follow up, the Mayo score was 82.3 ± 14.4 and the range of motion of elbow stiffness was (108.8 ± 36.0)°; showing significant differences when compared with preoperation (P lt; 0.05). According to Mayo evaluation, the results were excellent in 11 cases, good in 18 cases, fair in 2 cases, and poor in 2 cases, the excellent and good rate was 87.88%. Thirty-one patients achieve satisfactory results. Two patients were not satisfied with the result, but the satisfactory results were achieved by a second arthrol ysis. Conclusion Open elbow arthrolysis and postoperative rehabil itation for patients with elbow stiffness can improve joint function and ensure the stabil ity of elbows.

      Release date:2016-09-01 09:08 Export PDF Favorites Scan
    2 pages Previous 1 2 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南