Objective To summarize the research progress of secondary fracture of adjacent vertebral body after percutaneous vertebroplasty (PVP) and percutaneous kyphoplasty (PKP). Methods Recent literature concerning PVP and PKP was extensively reviewed and summarized. Results The main reasons of secondary fracture of adjacent vertebral body after PVP and PKP are the natural process of osteoporosis, the initial fracture type, the bone cement, the surgical approach, the bone mineral density, and other factors. Conclusion Secondary fracture of adjacent vertebral body after PVP and PKP is a challenge for the clinician, a variety of factors need to be suficiently considered and be confirmed by a lot of basic and clinical epidemiological studies.
Objective To evaluate the effectiveness of Confidence high viscosity bone cement system and postural reduction in treating acute severe osteoporotic vertebral compression fracture (OVCF). Methods Between June 2004 and June2009, 34 patients with acute severe OVCF were treated with Confidence high viscosity bone cement system and postural reduction. There were 14 males and 20 females with an average age of 72.6 years (range, 62-88 years). All patients had single thoracolumbar fracture, including 4 cases of T11, 10 of T12, 15 of L1, 4 of L2, and 1 of L3. The bone density measurement showed that T value was less than —2.5. The time from injury to admission was 2-72 hours. All cases were treated with postural reduction preoperatively. The time of reduction in over-extending position was 7-14 days. All patients were injected unilaterally. The injected volume of high viscosity bone cement was 2-6 mL (mean, 3.2 mL). Results Cement leakage was found in 3 cases (8.8%) during operation, including leakage into intervertebral space in 2 cases and into adjacent paravertebral soft tissue in 1 case. No cl inical symptom was observed and no treatment was pearformed. No pulmonary embolism, infection, nerve injury, or other complications occurred in all patients. All patients were followed up 12-38 months (mean, 18.5 months). Postoperatively, complete pain rel ief was achievedin 31 cases and partial pain refief in 3 cases; no re-fracture or loosening at the interface occurred. At 3 days after operation and last follow-up, the anterior and middle vertebral column height, Cobb angle, and visual analogue scale (VAS) score were improved significantly when compared with those before operation (P lt; 0.05);and there was no significant difference between 3 days and last follow-up (P gt; 0.05). Conclusion Confidence high viscosity bone cement system and postural reduction can be employed safely in treating acute severe OVCF, which has many merits of high viscosity, long time for injection, and easy-to-control directionally.
ObjectiveTo evaluate the feasibility and short-term effectiveness of bilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach for osteoporotic vertebral compression fracture (OVCF) of lumbar.MethodsA retrospective analysis was made on the clinical data of 93 patients with OVCF of lumbar who met the selection criteria between January 2018 and June 2019. According to the different surgical methods, they were divided into group A (44 cases, treated with bilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach) and group B [49 cases, treated with percutaneous kyphoplasty (PKP) via bilateral transpedicle approach]. There was no significant difference in gender, age, body mass index, T value of bone mineral density, injury cause, fractured level, time from injury to operation, comorbidities, and preoperative Cobb angle of injured vertebra, visual analogue scale (VAS) score, and Oswestry disability index (ODI) between the two groups (P>0.05). The operation time, intraoperative fluoroscopy times, bone cement injection amount, and incidence of bone cement leakage were recorded and compared between the two groups; Cobb angle of the injured vertebrae, VAS score, and ODI were measured before operation, at 2 days and 1 year after operation. The contralateral distribution ratio of bone cement was calculated according to the anteroposterior X-ray film at 2 days after operation.ResultsThe operation time and the intraoperative fluoroscopy times in group A were significantly less than those in group B (P<0.05). There was no bone cement adverse reactions, cardiac and cerebrovascular adverse events, and no complications such as puncture needles erroneously inserted into the spinal canal and nerve injuries occurred in the two groups. Bone cement leakage occurred in 6 cases and 8 cases in groups A and B, respectively, all of which were asymptomatic paravertebral or intervertebral leakage, and no intraspinal leakage occurred; the bone cement injection amount and incidence of bone cement leakage between the two groups showed no significant differences (P>0.05). The contralateral distribution ratio of bone cement in group A was significantly lower than that in group B (t=2.685, P=0.009). Patients in both groups were followed up 12-20 months, with an average of 15.3 months. The Cobb angle of the injured vertebrae, VAS score, and ODI in the two groups were significantly improved at 2 days after operation, however, the Cobb angle of the injured vertebra at 1 year after operation was significantly lost when compared with the 2 days after operation, the VAS score and ODI at 1 year after operation were significantly further improved when compared with the 2 days after operation, the differences were all significant (P<0.05). There was no significant difference in the Cobb angle of the injured vertebrae, VAS score, and ODI between the two groups at each time point after operation (P>0.05).ConclusionBilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach is comparable to bilateral PKP in short-term effectiveness with regard to fracture reduction, reduction maintenance, pain relief, and functional improvement. It has great advantages in reducing operation time and radiation exposure, although it is inferior in bone cement distribution.
ObjectiveTo evaluate the effectiveness of Curved Diffusion Needle in unilateral percutaneous vertebroplasty (PVP) by compared with bilateral PVP. MethodsA clinical data of 93 patients with osteoporotic vertebral compression fracture (OVCF) treated with PVP between January 2020 and January 2021 was retrospectively analyzed, including 47 patients underwent unilateral PVP assisted with Curved Diffusion Needle (unilateral group) and 46 patients underwent bilateral PVP (bilateral group). There was no significant difference in gender, age, cause of injury, time from injury to operation, T value of bone mineral density, AO classification, distribution of injured vertebrae, and preoperative visual analogue scale (VAS) score, Oswestry disability index (ODI), relative height of injured vertebrae, and Cobb angle between the two groups (P>0.05). The operation time, the amount of bone cement injection, the incidence of bone cement leakage, the bone cement diffusion distribution, VAS score, ODI, the relative height of injured vertebrae, and Cobb angle were recorded and compared between the two groups. Results All operations successfully completed. The operation time was significantly shorter in unilateral group than in bilateral group (t=?13.936, P=0.000), and the amount of bone cement injection was significantly less in unilateral group than in bilateral group (t=?13.237, P=0.000). The incidence of bone cement leakage in unilateral group was 19.14%, which was significantly lower than that in bilateral group (39.13%) (χ2=4.505, P=0.034). The score of bone cement distribution in unilateral group was 7.0±1.3, of which 41 cases were excellent and 6 cases were well. The score of bilateral group was 7.4±0.8, of which 43 cases were excellent and 3 cases were well. There was no significant difference in score and grading of bone cement distribution between the two groups (t=?1.630, P=0.107; Z=?1.013, P=0.311). All patients were followed up and the follow-up time was 3-10 months (mean, 6.5 months) in unilateral group and 3-10 months (mean, 6.1 months) in bilateral group. The VAS score, ODI, the relative height of injured vertebrae, and Cobb angle at 24 hours after operation and last follow-up were significantly better than those before operation in the two groups (P<0.05). There were significant differences in all indicators between 24 hours after operation and last follow-up (P<0.05). There was no significant difference in all indexes between the two groups (P>0.05) at the same time point after operation. During follow-up, there was no complication such as contralateral vertebral collapse, refracture, adjacent vertebral fracture, or local kyphosis in the two groups. ConclusionUnilateral PVP assisted with Curved Diffusion Needle for OVCF is beneficial to the distribution of bone cement, which can not only achieve similar effectiveness to bilateral PVP, but also achieve shorter operation time, less bone cement injection, and lower risk of bone cement leakage.
ObjectiveTo compare the short-term effectiveness and safety of unipedicular versus bipedicular percutaneous kyphoplasty (PKP) for osteoporotic vertebral compression fracture (OVCF) with posterior wall broken.MethodsThe clinical data of 68 patients with OVCF with posterior wall broken and without posterior ligament complex injury and spinal cord nerve injury between June 2013 and December 2018 were retrospectively analyzed. According to the different operative approaches, the patients were divided into two groups: group A (36 cases received PKP via bilateral pedicle puncture) and group B (32 cases received PKP via unilateral pedicle paracentesis). There was no significant difference between the two groups in gender, age, fracture vertebra distribution, time from injury to operation, preoperative pain visual analogue scale (VAS) score, Oswestry disability index (ODI), and height of injured vertebra (P>0.05). The operation time, intraoperative fluoroscopy times, and bone cement volume were recorded and compared between the two groups. The VAS score and ODI score were used to evaluate the effectiveness before operation, at 1 day and 6 months after operation; the height of injured vertebra was measured on the lateral X-ray film, and the recovery height of injured vertebra at 1 day after operation and the loss height of injured vertebra at 6 months after operation were calculated; the intraoperative and postoperative complications of the two groups were recorded.ResultsThe operation time, intraoperative fluoroscopy times, and bone cement volume of group B were significantly less than those of group A (P<0.05). All patients were followed up 10-35 months, with an average of 18 months. During the operation, there were 2 cases (5.56%) of cement leakage in group A and 9 cases (28.13%) in group B, showing significant difference (χ2=4.808, P=0.028). There was no adverse reactions of bone cement, iatrogenic spinal cord injury, infection of puncture port, or other complications in the two groups. During the follow-up period, there were 3 cases (8.3%) of adjacent vertebral fractures in group A and 2 cases (6.3%) in group B, showing no significant difference between the two groups (χ2=0.027, P=0.869). The height of injured vertebra of the two groups at 1 day and 6 months after operation were significantly improved when compared with preoperative ones (P<0.05). There was no significant difference in the height of injured vertebrae and the recovery height of injured vertebra at 1 day after operation between the two groups (P>0.05). However, at 6 months after operation, the height of injured vertebra in group B was significantly lower than that in group A (P<0.05), and the loss height of injured vertebra in group B was significantly higher than that in group A (P<0.05). The VAS score and ODI score at 1 day and 6 months after operation were significantly improved when compared with preoperative ones in both groups (P<0.05), but there was no significant difference between the two groups (P>0.05).ConclusionBoth bipedicular and unipedicular PKP can obtain satisfactory effectiveness for the treatment of OVCF with posterior wall broken, but the former may have advantages of lower cement leakage rate and less height loss.
Objective To explore the effectiveness of posterior single-level osteotomy with 360° release and correction for the treatment of osteoporotic vertebral compression fractures (OVCF) complicated with moderate to severe kyphosis. Methods A retrospective analysis was conducted on 11 patients with OVCF complicated with moderate to severe kyphosis between January 2022 and March 2023. There were 4 males and 7 females with an average age of 57 years ranging from 47 to 69 years. The disease duration ranged from 3 to 15 months, with an average of 7 months. Fracture segments included T11 in 3 cases, T12 in 5, L1 in 2, and L2 in 1. The T value of lumbar spine bone density was ?5.0 to ?2.0, with an average of ?3.5. The preoperative neurological function was grade E according to Frankel grading. The Pfirrmann classification of the intervertebral disc above the injured vertebra was grade Ⅲ in 8 cases and grade Ⅳ in 3 cases. All patients underwent posterior single-level osteotomy with 360° release and correction. The operation time, intraoperative blood loss, hospital stay, and postoperative complications were recorded. Thoracolumbar local kyphosis Cobb angle, the mean height of the functional spinal unit (FSU), the sagittal vertical axis (SVA), and the sagittal index (SI) were measured. The visual analogue scale (VAS) score and Oswestry disability index (ODI) were used to evaluate the improvement of pain and function before operation, at 1 month after operation, and at last follow-up. Results The operation successfully completed in all patients, and there was no obvious complication. The operation time ranged from 100 to 190 minutes, with an average of 153 minutes, and the intraoperative blood loss ranged from 200 to 800 mL, with an average of 468 mL. The length of hospital stay was 8-14 days (mean, 12 days). All patients were followed up 6-24 months, with an average of 12.4 months. At last follow-up, all the 11 patients had bony fusion in the osteotomy area, and there was no displacement or subsidence of the Cage, no complication such as internal fixation failure or pseudarthrosis formation was found. The Cobb angle of local thoracolumbar kyphosis, the mean height of FSU, SVA, and SI significantly improved immediately after operation and at last follow-up when compared with preoperative ones, and the VAS score and ODI also significantly improved at 1 month after operation and at last follow-up (P<0.05); there was no significant difference in above indexes between the two time points after operation (P>0.05). Conclusion Posterior single-level osteotomy with 360° release and correction is an effective surgical method for treating OVCF complicated with moderate to severe kyphosis, with definite early effectiveness.
ObjectiveTo evaluate the effectiveness of percutaneous vertebroplasty (PVP) in the treatment of osteoporotic vertebral compression fractures with or without intravertebral clefts by unilateral approach and the impact of intravertebral clefts on the effectiveness. MethodsThe clinical data of 65 patients who met the inclusion criteria of osteoporotic vertebral compression fracture were retrospectively analyzed. According to having intravertebral clefts or not, the patients were divided into 2 groups: cleft group (group A, n=25) and non-cleft group (group B, n=40). There was no significant difference in gender, age, cause of injury, the level of fracture vertebrae, degree of damage, and interval of injury and operation between 2 groups (P gt; 0.05). All patients were given PVP procedure by unilateral approach. The operation time, the injected volume of bone cement, time to ambulate, complications, and adjacent vertebral re-fracture were recorded. The height of anterior and middle column and the posterior convex Cobb angle of injured spine were measured on the lateral X-ray film in standing position at preoperation and 1, 48 weeks after operation. The visual analogue scale (VAS) score and Oswestry disability index (ODI) system were used to evaluate the pain relief and improvement of daily activity function respectively at preoperation and 1, 4, and 48 weeks after operation. ResultsThere was no significant difference in the operation time and time to ambulate between 2 groups (P gt; 0.05). The injected volume of bone cement in group B was significantly less than that in group A (t=1.833, P=0.034). Asymptomatic cement leakage occurred in 6 patients (4 in group A and 2 in group B), in group A including 1 case of venous leakage, 2 cases of paravertebral leakage, and 1 case of intradiscal leakage; in group B including 2 cases of venous leakage. No symptomatic pulmonary embolism was observed. The vital sign was stable during operation and postoperatively. All patients were followed up 12-30 months (mean, 18.5 months). No re-fracture of the vertebrae occurred during the follow-up. The postoperative VAS score, ODI, the height of anterior and middle column, and the posterior convex Cobb angle of injured spine were improved significantly when compared with the preoperative ones in 2 groups (P lt; 0.05), but no significant difference was found between 2 groups at pre- and post-operation (P gt; 0.05). ConclusionPVP by unilateral approach is safty and efficacy in the treatment of osteoporosis vertebral compression fracture combined with intravertebral clefts. Intravertebral clefts have no significant impact on the effectiveness in the pain relief and function improvement.
Objective To evaluate the efficacy of percutaneous kyphoplasty (PKP) in hyperextension position for the treatment of osteoporotic vertebral compression fracture (OVCF) with vacuum phenomenon. Methods Between April 2004and August 2009, 35 patients who suffered from OVCF with vacuum phenomenon were treated with PKP in hyperextension position, 8 patients were excluded because of lost follow-up. In 27 follow-up cases, there were 9 males and 18 females with an average age of 75 years (range, 58-90 years) and with an average disease duration of 9.8 months (range, 2-17 months). One vertebral body was involved in 26 cases and 2 vertebral bodies were involved in 1 case. According to the imaging examination and Krauss et al. criterion, all patients were diagnosed as having vertebral vacuum phenomenon. Refer to the lateral X-ray views, the height and the kyphotic angle of the involved vertebral body were measured pre- and postoperatively. The surgical outcomes were evaluated by using visual analogue scale (VAS) and Oswestry disabil ity index (ODI) system. Results All operations were performed successfully with no severe compl ication. The mean follow-up of 27 patients was 32 months (range, 24-58 months). The mean cl inical heal ing time of OVCF was 4 months (range, 3-6 months). The VAS score, ODI system, anterior and medial height of involved vertebral body, kyphotic angle of involved vertebral body were improved significantly at 1 week after operation and at last follow-up (P lt; 0.05); there was no significant difference between at 1 week after operation and at last follow-up (P gt; 0.05). There was no significant difference in the posterior height of involved vertebral body among different postoperative time-points (P gt; 0.05). Asymptomatic cement leakage occurred in 3 patients. Adjacent vertebral fracture occurred in 1 patient at 7 months. Intravertebral vacuums showed a compact and sol id cement fill ing pattern. Conclusion PKP in hyperextension position can significantly rel ieve back pain, restore vertebral height, and correct local kyphosis in the treatment of OVCF with vacuum phenomenon.
ObjectiveTo investigate the risk factors of adjacent fractures after percutaneous vertebroplasty (PVP) for osteoporotic vertebral compression fracture (OVCF).MethodsA total of 2 216 patients who received PVP due to symptomatic OVCF between January 2014 and January 2017 and met the selection criteria were selected as study subjects. The clinical data was collected, including gender, age, height, body mass, history of smoking and drinking, whether the combination of hypertension, diabetes, coronary arteriosclerosis, chronic obstructive pulmonary disease (COPD), bone mineral density, the number of fractured vertebrae, the amount of cement injected into single vertebra, the cement leakage, and whether regular exercise after operation, whether regular anti-osteoporosis treatment after operation. Firstly, single factor analysis was performed on the observed indicators to preliminarily screen the influencing factors of adjacent fractures after PVP. Then, logistic regression analysis was carried out for relevant indicators with statistical significance to screen risk factors.ResultsAll patients were followed up 12-24 months, with an average of 15.8 months. Among them, 227 patients (10.24%) had adjacent fractures. The univariate analysis showed that there were significant differences between the fracture group and non-fracture group in age, gender, preoperative bone density, history of smoking and drinking, COPD, the number of fractured vertebrae and the amount of bone cement injected into the single vertebra, as well as regular exercise after operation, regular anti-osteoporosis treatment after operation (P<0.05). Further multivariate logistic regression analysis showed that the elderly and female, history of smoking, irregular exercise after operation, irregular anti-osteoporosis treatment after operation, low preoperative bone density, large number of fractured vertebrae, and small amount of bone cement injected into the single vertebra were risk factors for adjacent fractures after PVP in OVCF patients (P<0.05).ConclusionThe risk of adjacent fractures after PVP increases in elderly, female patients with low preoperative bone mineral density, large number of fractured vertebrae, and insufficient bone cement injection. The patients need to quit smoking, regular exercise, and anti-osteoporosis treatment after PVP.
ObjectiveTo review the latest progress in minimally invasive treatment of osteoporotic vertebral compression fracture (OVCF). MethodsRelevant literature on minimally invasive treatment of OVCF was reviewed, different minimally invasive technologies were analyzed, compared, and future prospected. ResultsThere are various minimally invasive technologies for treatment of OVCF to aim at analgesia, deformity correction, and vertebral stabilization, thus improving the patients' quality of life. Percutaneous vertebroplasty as the classical technology has a good effectiveness on analgesia, while percutaneous kyphoplasty has a better performance in vertebral height restoration and a lower complication of cement leakage. Obvious deformity correction can be achieved by skyphoplasty, with a risk of endplate damage and uncertain vertebral height maintenance. With OptiMesh vertebroplasty, physiological environment within the fractured vertebra is less likely to be disturbed, but paravertebral tissues are more vulnerable due to a bigger working cannal. Compared with traditional bone cement, Cortoss has advantages of less toxicity, less heat release, and proper stiffness. In addition, the combination use of different minimally invasive technologies has greatly extended the surgical indications of OVCF and improved the success rate. ConclusionMinimally invasive treatment of OVCF is becoming more safety and efficacy with the development of new material and technology, however, further studies are required for quality confirmation and better improvement.