Lung cancer is one of the malignant tumors with the greatest threat to human health, and studies have shown that some genes play an important regulatory role in the occurrence and development of lung cancer. In this paper, a LightGBM ensemble learning method is proposed to construct a prognostic model based on immune relate gene (IRG) profile data and clinical data to predict the prognostic survival rate of lung adenocarcinoma patients. First, this method used the Limma package for differential gene expression, used CoxPH regression analysis to screen the IRG to prognosis, and then used XGBoost algorithm to score the importance of the IRG features. Finally, the LASSO regression analysis was used to select IRG that could be used to construct a prognostic model, and a total of 17 IRG features were obtained that could be used to construct model. LightGBM was trained according to the IRG screened. The K-means algorithm was used to divide the patients into three groups, and the area under curve (AUC) of receiver operating characteristic (ROC) of the model output showed that the accuracy of the model in predicting the survival rates of the three groups of patients was 96%, 98% and 96%, respectively. The experimental results show that the model proposed in this paper can divide patients with lung adenocarcinoma into three groups [5-year survival rate higher than 65% (group 1), lower than 65% but higher than 30% (group 2) and lower than 30% (group 3)] and can accurately predict the 5-year survival rate of lung adenocarcinoma patients.
Illumimaton intensities of 6 indirect opthalmoscopes and 5 slit lamps were measured and calculated. The results showed the retinal irradiance from these instruments is quite high with dilated pupils ahd clear media. Although such illuminating intensity is a potential risk factor for the human retina, with careful use and reduced intensity, they are relatively safe. We suggest that ophthalmologists try their best to avoid using brighter source beyond useful illumination and unnecessary wide slit. (Chin J Ocul Fundus Dis,1992,8:133-137)
OBJECTIVE:To investigate the value of psychophysical testing for the macular function in the diegnosis of diabetic retinopathy(DR). METHODS:To compare the testing results of macular light sensitivity and pattern visual evoked potential(P-VEP)of 30 eyes of 15 normal person with those of 82 eyes of 41 diabetic patients(27 eyes without DR,55 eyes with simple type DR ). RESULTS:The macular light sensitivity of diabetic patients is much lower than that of normal Control group(plt;0.05). In the diabetic group, 62.19% is abnormal in macular light sensitivity, 69.51% in P-VEP. CONCLUSION: Testing of macular light sensitivit y is helpful in finding of diabetic retinopathy and early deterioration of macular visual function in diabetics. (Chin J Ocul Fundus Dis,1996,12: 223-224)
PURPOSE:To evaluate the activitv of protein kinase C(PKC) in response to retinal photochemical insult in rat. Furthermore, to investigate the effect of dexamethasone(DXM ) on PKC activity. METHODS :The experiments were performed on 48 SI') rats whieh were separated into two groups,control and treated groups,and the latter received daily intraperitoneal injections of DXM (1 mg/kg)for 5 consecutive days,starting 3 days before light exposure. The animals were continually exposed to green fluorescent light (510nm~560nm) with an illuminance level of (1 900plusmn;106.9)lx for 24 hrs.The retinal enzyme activity of PKC was tested at 6 hrs,1 day,3 days,7 days,and 14 days after light exposure respectively. RESULTS:In animal models,PKC activity showed a transient increase in both groups at 6 hrs after light exposure and then decrease persistently there alter. The activity of PKC was unresponsive to DXM intervention. CONCLUSIONS :These results suggested that the persistent lower PKC activity might result in disturbance of retinal function in rat retinal photochemical injury. (Chin J Ocul Fundus Dis,1997,13: 78-80)
Objective To study the retinal light sensitivity of central visual field in normal children. Methods The QZS-Ⅱ automated perimetry was used to assess the visual field of centro-30deg;and centro-6deg; in normal or ametropic eyes in 60 eyes of 5~9 years old children. Results The mean sensitivity(MS)was not influenced by sex,age and laterality and ametropia of the eye.The normal type of dB distribution was obviously higher than the abnormal(P<0.01).We set normal range as 30deg;MS>19.3 dB, 6deg;MS>22.5 dB.The abnormality of value or distribution didnprime;t appear in the same field. Conclusions In normal children,the dB distribution of visual field was mainly of the normal type.We suggest that in evaluating function of visual filed of the children,the dB distribution of centro-30deg;and centro-6deg;field and the value of MS should be included. (Chin J Ocul Fundus Dis, 1999, 15: 137-138)
Objective To evaluate the efficacy of light cured composite resin and glass ionomer cement for wedge shaped defect filling. Methods PubMed, The Cochrane Library (Issue 3, 2016), EMbase, CNKI, CBM, VIP and WanFang Data were searched from inception to April 5th 2016, to collect randomized controlled trials (RCTs) of light cured composite resin versus glass ionomer cement for wedge shaped defect filling. According to the inclusion and exclusion criteria, two reviewers independently screened literature, extracted data and assessed the risk of bias of included studies. Then, meta-analysis was performed by RevMan 5.2 software. Results A total of 12 studies, involving 3 744 cases of teeth were included. Meta-analysis results showed that there was no significant difference in the two groups on the shedding rate after 2 years (OR=1.19, 95%CI 0.70 to 2.02,P=0.53). But the wear rate of the light cured composite resin group was significantly lower than that of the glass ionomer cement group (Peto OR=0.31, 95%CI 0.22 to 0.44,P<0.000 01). The light cured composite resin group had higher rate of micro leakage or secondary caries rate (OR=1.83, 95%CI 1.11 to 3.01,P=0.02) and incidence of endodontic or periapical lesions (Peto OR=2.84, 95%CI 1.82 to 4.45,P<0.000 01) than the glass ionomer cement group. Conclusion Glass ionomer cement for filling wedge-shaped defects of 2 years after the wear degree is higher than the light cured composite resin, but the occurrence probability of micro leakage or secondary caries and stimulation to pulp are lower than the light cured composite resin. Because of the limitations of the quality of the included studies, the above conclusion still needs to be verified by more high-quality studies.
Medical image registration plays an important role in medical diagnosis and treatment planning. However, the current registration methods based on deep learning still face some challenges, such as insufficient ability to extract global information, large number of network model parameters, slow reasoning speed and so on. Therefore, this paper proposed a new model LCU-Net, which used parallel lightweight convolution to improve the ability of global information extraction. The problem of large number of network parameters and slow inference speed was solved by multi-scale fusion. The experimental results showed that the Dice coefficient of LCU-Net reached 0.823, the Hausdorff distance was 1.258, and the number of network parameters was reduced by about one quarter compared with that before multi-scale fusion. The proposed algorithm shows remarkable advantages in medical image registration tasks, and it not only surpasses the existing comparison algorithms in performance, but also has excellent generalization performance and wide application prospects.
ObjectiveTo compare the safety, effectiveness, and stability of 3D Max lightweight patch and standard patch in laparoscopic transabdominal preperitoneal (TAPP) herniorrhaphy. MethodsThe clinical data of 147 patients who underwent laparoscopic TAPP herniorrhaphy with 3D Max from May 2013 to May 2014 in this hospital were collected. Of all the patients, the lightweight patches were used in 75 patients (observation group), the standard patches were used in 72 patients (control group). The mean operative time, mean early postoperative ambulation time, mean bleeding volume, postoperative pain, postoperative foreign body sensation, complications, average hospital stay, and average costs were compared between these two groups. The postoperative pain point was determined by using visual analogue scale (VAS). The foreign body sensation of postoperative groin area was determined basing on the pain point. ResultsThere were no significant differences in the terms of the mean operation time, the mean early postoperative ambulation time, the mean bleeding volume, the average costs, and the average hospital stay between the observation group and the control group (P > 0.05). On postoperative 2 d, the pain point of the observation group was slightly lower than that of the control group, but there was no statistically significant difference between these two groups (P=0.132); On postoperative 1 month and 6 months, the postoperative pain points of the observation group were significantly lower than those of the control group, the differences were statistically significant (P=0.031, P=0.018). There was no recurrence of hernia and complications in the two groups. ConclusionsThe cost of 3D Max lightweight patch in laparoscopic TAPP herniorrhaphy application is slightly higher than that in standard patch, but it could alleviate postoperative pain, reduce postoperative foreign body sensation, and make patients feel more comfortable. It is safe, effective, and stable in clinical application of laparoscopic TAPP herniorrhaphy.
Wistar rats weaned were raised through 10 weeks under cyclic illumination of 12 hours light and 12 hours darkness,with four different fluorescent colour lighting condition:75 lx and 300lx blue light,300 lux white and 300lux pink light to study the change of superoxide dismutases(SOD)and lipid peroxied(LPO)in the retina.This paper shows that photic oxidative reaction reduces SOD in the retina and oxidizes polyunsaturated fatty acids to become LPO and that complex visible light oxidizes retina easier than simple wave lengths visible light does.The shorter the wave lengths of visible light is and the brighter the illumination is the more serious the oxidative damage of the retina is. (Chin J Ocul Fundus Dis,1993,9:14-16)
Animal localization and trajectory tracking are of great value for the study of brain spatial cognition and navigation neural mechanisms. However, traditional optical lens video positioning techniques are limited in their scope due to factors such as camera perspective. For pigeons with excellent spatial cognition and navigation abilities, based on the beacon positioning technology, a three-dimensional (3D) trajectory positioning and tracking method suitable for large indoor spaces was proposed, and the corresponding positioning principle and hardware structure were provided. The results of in vitro and in vivo experiments showed that the system could achieve centimeter-level positioning and trajectory tracking of pigeons in a space of 360 cm × 200 cm × 245 cm. Compared with traditional optical lens video positioning techniques, this system has the advantages of large space, high precision, and high response speed. It not only helps to study the neural mechanisms of pigeon 3D spatial cognition and navigation, but also has high reference value for trajectory tracking of other animals.