A mechanical study on the bones of 29 rabbits following implantation of carbontendon was carried out. The rabbits were divided into seven groups according to the observation time (2,4,6,8,12,20 and 30 weeks after operation). A bundle of artificial tendon composed of 7,000 carbon fibers was passedthrough a tunnel in the tibia, and both ends of the artificial tendon were ligated to the muscle fibers. The mechanical strength and histological structure of the carbonbone junction and their relationship were studied in each group. Carbon fiberwas split and degradated in six to eight weeks after operation. The tensile strength of carbontendon in the soft tissue was decreased from 82±4.6N in the second week to 27±5.31N and6.3±1.81N in the sixth and eighth week respectively. The tensile strength of carbontendon increased from 3.01±1.2N to 6.1±2.01N at the carbon -tendon-bone junction in the bone. The tensile strength of carbon-tendon was unsatisfactory for implantation into bone. The carbon-tendon was split and degradated and the tensile strength was not b enough to cope with the early functional exercises.
The aim of this experiment was to study the osteogenesis in vivo of allogenic osteoblast combined culture with calcium phosphate composites. The osteoblasts were obtained by enzymatic digestion of periosteum from fibula subcultured to 13 generations, the cells were combined culture with hydroxyapatite and biphasic calcium phosphate. Subseguently, the composite was implanted into rabbits subcutaneously or intramuscularly. The blank material was implanted in the contralateral side as control. Four weeks later, all animals were sacrificed. All the implants were examined by gross observation, histological examination and EDXA. The results showed: 1. obvious ingrowth of connective tissue with very little inflammatory reaction; 2. new bone formation in the composites with deposit of Ca and P on the surface of osteoblast, but none in the blank materials; 3. no significant difference of new bone formation between the different sites of implantation or different materials, but those implanted intramuscularly had lamellae form of new bone while those implanted subcutaneously had only mineralization of extracellular matrix. The conclusion were: 1. the composites are biocompatible with prior osteogenesis property; 2. periosteal-derived allogenic osteoblasts obatined by enzymatic digestion could survive following implantation with bioactivity; 3. rich blood supply might be advantageous to new bone formation and its maturation.
OBJECTIVE: To evaluate the clinical effect of drilling procedure following the hydroxyapatite orbital implantation. METHODS: From February 1996 to April 2000, 146 consecutive patients who received hydroxyapatite orbital implant were drilled and inserted a motility peg 6 to 16 months after hydroxyapatite implantation. Among them, there were 97 males and 49 females, aged from 18 to 60 years old, of the 146 motility pegs, 36 were sleeved pegs and 110 were nonsleeved. Goldman visual field analyzer was applied to measure the degree of artificial eye’s movement before and after drilling. RESULTS: Followed up for 1 to 40 months, no secondary infection occurred. The mobility of the prosthesis increased from (18.7 +/- 3.8) degrees preoperatively to (42.3 +/- 3.7) degrees postoperatively. CONCLUSION: The delayed drilling procedure and motility peg insertion improve the range of movement and the sensitivity of the artificial eye with a low rate of complications.
From the results of this experiment, it showed that the implanted tendon was gradually extruded from the tibia hole and attached to the periosteum. The dominant breeding of tissue cells, cytodynamics, the perimeter ratio of tendon/bone and the effect of revascularization were discussed in detail.
Objective To design a novel stentless porcine aortic bioprosthesis and test the feasibility and its function in vitro after the valve was implanted by a modified method. Methods Six stentless porcine aortic bioprosthesis were divided into two groups according to different implantation, single layer suture group: new improvement stentless porcine aortic bioprosthesis sutured with single layer was implanted; double layer suture group: stentless porcine aortic bioprosthesis developmented by our laboratory used double layer suture was implanted. Each group contained three scales: 23 mm ,25 mm and 27 mm. Analogue ex vivo aortic valve replacement was performed , the feasibility of the new implantation was detected. Effective orifice area, transvalvular pressure gradient and regurgitation ratio were recorded at the cardiac output of 2.0 L/min, 3.5 L/min, 5.0 L/min and 7.0 L/min under the guideline of International Organization for tandardization (ISO)5840. Results The average aortic valve implantation time used for single layer suture and tradition double layer suture were 50 min and 70 min respectively. The transvalvular pressure gradient in the single layer suture group were significantly lower than those in double layer suture group under the flow of 5.0 L/min in 23 mm valve and 27 mm valve (13.51±0.51 mm Hg vs. 14.44±0.99 mm Hg, 7.36±0.19 mm Hg vs. 7.53±0.28 mm Hg;P<0.01);and the effective orifice area in the single layer suture group were larger than those in double layer suture group in the same case(1.87±0.06 cm2 vs. 1.76±0.08 cm2, 2.26±0.07 cm2 vs. 2.16±0.05 cm2;P<0.01). There was no statistically difference in other parameters between both groups. Conclusion The novel design of new improvement stentless porcine aortic bioprosthesis used single layer suture has good hemodynamic characteristics as the nature structure . The modified suture method decrease the implantation time.Nemerical data of the evaluation in vitro show that the difference between single layer suture group and double layer suture group in effective orifice area,transvalvular pressure gradient and regurgitation ratio haveno statistical significance. This experiment is the foundation of the animal and clinical experiment in the future.
Objective To investigate the biocompatibility of acellular urinary bladder submucosa (AUBS). Methods The acellular collagen matrix of human urinary bladder submucosa was developed using freeze-thawed enzymatic treatment and freeze-drying technique. Human oral keratinocytes were cultured and seeded on AUBS at a density of 2×106/ml in vitro.The proliferation of the cells were observed. Pockets were created in the abdominal muscle wall of 18 SD rats. AUBS in size 1 cm×1 cm was implanted into the pocket. The grafts were observed by light microscope 3, 6, 10, 14, 21 and 28 days after operation. Results AUBSmainly consisted of collagen fibers with a three-dimensional network structure. After the oral keratinocytes were seeded, continous oral epithelium layer was formed on the surface of AUBS after 10 days in vitro. Histological observation of the grafted AUBS showed progressive cell infiltration at 6 days. New capillaries formed at 14 days. The collagen fibers arranged regularly at 28 days after implantation. Conclusion Freeze-dried AUBS may be used as a suitable scaffold for tissue regeneration, which can induce cell proliferation both in vivo and in vitro and has good biocompatibilty.
Objective To explore the effective autologous bone marrow stem cell dosage for treatment of severe lower limb ischemia. Methods From December 2003 to December 2004, 22 cases of bilateral lower limb ischemia were treated with autologous bone morrow cell transplantation. All the patients were randomly divided into two groups according to ischemia degree. In group A(severe ischemia side), the amount of transplanted autologous bone marrow cells was more than 1×108, and ingroup B(mild ischemia side), the amount was less than 1×105. A series of subjective indexes, such as improvement of pain, cold sensation and numbness, and objective indexes, such as increase of ankle/brachial index (ABI) and transcutaneous oxygen pressure (TcPO2), angiography, amputation rate, and improvement of foot wound healing were used to evaluate the effect of autologous bone marrow stem cells implantation. Results The rates of pain relief were 90.0% in group A and 16.7% in group B (Plt;0.01); the rates of cold sensation relief were 90.5% in group A and 5.3% in group B(Plt;0.01);the improvement of numbness was 62.5% in group A and 9.1% in group B(Plt;0.01). Increase of ABI was 31.8% and 0 in groups A and B respectively(Plt;0.01) at 4 weeks after implantation. Increase of TcPO2was 94.4% and 11.1% in groups A and B respectively(Plt;0.01) at 4 weeks after implantation. Twelve cases of angiography showed rich new collateral vessels in 100% of the limbs in group A while no remarkable new collateral vessel in group B. The amputation rates were 4.5% in group A and 27.3% in group B(Plt;0.05) at 4 weeks after implantation. The rate of improvement of foot wound healing was 75% in group A and there was no changein wound healing in group B after 4 weeks of implantation. Conclusion The effectiveness of autologous bone marrow stem cell implantation depends on the number of implanted stem cells. Effectiveness is expected in most patients if the implanted stem cell is more than 1×108, whereas there would be little effect if the cell number is less than 1×105.
Objective To evaluate the effectiveness and safety of implanted sustained-release fluorouracil in gastric cancer surgery. Methods Literature search was conducted in the following databases: PubMed, EMbase, The Cochrane Library (Issue 6, 2012), CNKI, VIP and WanFang Data from inception to June, 2012. Randomized controlled trials (RCTs) or quasi-randomized controlled trials on implanted sustained-release fluorouracil for gastric cancer were included. Two reviewers independently identified the literature according to the inclusion and exclusion criteria, and then extracted the data and assessed the quality of the included studies. Then, meta-analysis was conducted using RevMan 5.1 software. Results A total of 7 studies involving 742 patients were included. The results of meta-analysis showed no significant difference in the rate of postoperative complications between the two groups (OR=0.93, 95%CI 0.54 to 1.59, P=0.79), while a significant reduction was found in the recurrence rate in the sustained-release fluorouracil group during 1 to 3 year follow-up (1 year after surgery: OR=0.32, 95%CI 0.22 to 0.46, P=0.02; 2 years after surgery: OR=0.19, 95%CI 0.08 to 0.42, Plt;0.001; 3 years after surgery: OR=0.40, 95%CI 0.24 to 0.67, P=0.004). As for the survival rate, no significant difference was found between the two groups 1 year after surgery (OR=1.98, 95%CI 0.92 to 4.25, P=0.08), while it was significantly higher in the sustained-release fluorouracil group than in the control group 2 to 3 years after surgery (2 years after surgery: OR=2.63, 95%CI 1.17 to 5.91, P=0.02; 3 years after surgery: OR=2.42, 95%CI 1.53 to 3.83, P=0.002). Adverse reaction rates in the sustained-release fluorouracil group were lower than those in the control group, but without significantly differences between the two groups (OR=1.22, 95%CI 0.49 to 3.07, P=0.67). Conclusion Compared with the control group, implanted sustained-release fluorouracil for gastric cancer can significantly reduce the recurrence rate 1 to 2 years after surgery and improve the overall survival rate 2 to 3 years after surgery without increasing the incidences of the postoperative complications and adverse reaction. However, due to the limitation of quantity and quality of the included studies, this conclusion should be further confirmed by more high quality, larger sample and multi-center RCTs.
In order to investigate the possibility of repairing injuried tendon with living artificial tendon, after combining culture, subcultured autogenous tendon cells with carbon fibers were implanted into the calcaneous tendon of rabbits. In different stages, the synthesis of type I collagen and their relevant morphological changes were observed. The results showed as follows: after implantation, tendon cells continued proliferating. Four weeks after implantation, tendon cells were detached from the carbon fibers and proliferated and produced collagen among the carbon fibers. The collagen fibrils were linked with each other to formed a dense structure. In the linkage site, the collagen fibrils originated from the implants joined to that from the ruptured end of the tendon, which meaned that the implant was healed with the recipient tendon. Observed under scanning electronic microscope, the tendon cells were lined among the carbon fibers evenly and in order, the collagen fibrils joined each other and formed an network, the fibrils were lined parallel to the carbon fibers. Under transparent electron microscope, the nucleolus were clear and organelle were abundant.
Objective To introduce a new type of bileaflet mechanical prosthetic heart valve (GK bileaflet valve)and evaluate clinically the early hemodynamic effect and short term follow-up after its replacement. Methods Sixty-one patients with heart valve diseases were operated upon. The mitral valve replacement was performed in 34 patients, aortic valve replacement in 16 patients and double valve replacement in 11 patients. A total of 72 GK bileaflet mechanical valves were implanted, 45 in mitral position, and 27 in aortic position. Blood consistency and hemodynamics were monitored. Follow-up was carried out routinely to check whether there were some valve-related complications. Results There was no early mortality (〈30 d). Only one patient died of trauma 2 months after the operation. Follow-up was 100% and extended 1 to 2. 5 years. Without valve-related complications all patients had lived for more than 1 to 2.5 years. In 98% (60/61) of survivors heart functional performance had improved to New York Heart Association class Ⅰ or Ⅱ . Conclusion Early clinical results and short term follow up demonstrate that GK bileaflet prosthetic heart valve exhibits excellent hemodynamic properties, satisfied blood consistency and a low incidence of valve-related complications. Midterm and long-term results should be observed further.