Heart valve disease (HVD) is one of the common cardiovascular diseases. Heart sound is an important physiological signal for diagnosing HVDs. This paper proposed a model based on combination of basic component features and envelope autocorrelation features to detect early HVDs. Initially, heart sound signals lasting 5 minutes were denoised by empirical mode decomposition (EMD) algorithm and segmented. Then the basic component features and envelope autocorrelation features of heart sound segments were extracted to construct heart sound feature set. Then the max-relevance and min-redundancy (MRMR) algorithm was utilized to select the optimal mixed feature subset. Finally, decision tree, support vector machine (SVM) and k-nearest neighbor (KNN) classifiers were trained to detect the early HVDs from the normal heart sounds and obtained the best accuracy of 99.9% in clinical database. Normal valve, abnormal semilunar valve and abnormal atrioventricular valve heart sounds were classified and the best accuracy was 99.8%. Moreover, normal valve, single-valve abnormal and multi-valve abnormal heart sounds were classified and the best accuracy was 98.2%. In public database, this method also obtained the good overall accuracy. The result demonstrated this proposed method had important value for the clinical diagnosis of early HVDs.
Objective To observe the midterm haemodynamic manifestation of the home made C-L pugestrut tilting disc mechanical valve in aortic valve replacement, and to evaluate its function. Methods Twenty patients underwent aortic valve replacement over 5 years were collected and divided into two groups, the C-L pugestrut group (n=10):aortic valve was replaced by home-made C-L pugestrut tilting disc mechanical valve(21mm); Medtronic-Hall group (n=10):aortic valve was replaced by Medtronic-Hall mechanical valve (21mm). The peak transprosthetic gradients (△P), mean transprosthetic gradients (△Pm)and effective orifice area(EOA) at rest were compared between two groups. Results At rest, △P of the C-L pugestrut group and Medtronic-Hall group were 11.63±3.23mmHg vs. 9. 78±3. 35mmHg; △Pm of the C-L pugestrut group and Medtronic-Hall group were 6. 25±2. 32 mmHg vs. 5.85±2.32mmHg: EOA of the C-L pugestrut group and Medtronic-Hall group were 1.07±0.17 cm2 vs. 1.25±0.27 cm2. There was no statistically significance in △P, △Pm and EOA between two groups(P〉0.05). Conclusions The midterm haemodynamic results of the home-made C-L pugestrut tilting disc mechanical valve show that it has comparable haemodynamic results to those of Medtronic-Hall mechanical valve ,and it has well-done function. The home-made C-L pugestrut valve is one of the reliable mechanical heart valves.
Objective To investigate and evaluate the safety and effectiveness of the Chimney technique in mitral valve reoperation. Methods The clinical data of mitral valve reoperation patients who underwent Chimney surgery in Wuhan Asia Heart Hospital from 2019 to 2021 were retrospectively analyzed. Results A total of 26 patients were collected, including 7 males and 19 females, aged 27-67 (53.46±11.18) years. All patients had previous mitral valve surgery, including 23 mitral valve replacements and 3 mitral valve repairs. All patients received Chimney technique using the ideal artificial sized mitral valve, and 1 patient died of neurological complications in hospital. The cardiopulmonary bypass time and the aortic cross-clamping time were 231.11±77.05 min and 148.50±52.70 min, respectively. The mean diameter of the implanted mitral valve prosthesis was 29.08±0.68 mm, which was statistically different from pre-replacement valve prosthesis size of 26.69±0.77 mm (P<0.001). The mean transvalvular pressure gradient of the prosthetic mitral valve measured on postoperative echocardiography was 14.77±5.34 mm Hg, which was statistically different from preoperative value of 20.92±9.83 mm Hg (P=0.005). Conclusion The Chimney technique is safe and effective for reoperation in patients with small mitral annuli, which can not only reduce the risk of reoperation, but also obtain larger prosthetic valve implants with good hemodynamic characteristics and clinical outcomes.
ObjectiveTo investigate effect of cardiac function and tricuspid regurgitation (TR) degree of concomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent mitral valve replacement (MVR), and provide an objective basis for clinical decision about concomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent MVR. MethodsA total of 36 patients who underwent MVR from April to October 2013 in Department of Cardiovascular Surgery, West China Hospital, Sichuan University were enrolled in this study. Preoperative echocardiography showed mild TR and tricuspid valve annular end-diastolic dimension (TVAEDD)/body surface area (BSA)>21 mm/m2. All the 36 patients were randomly divided into a tricuspid annuloplasty group (TAPG group, n=18, including 7 males and 11 females) and a no tricuspid annuloplasty group (NTAPG group, n=18, including 6 males and 12 females). One week and 6 months postoperative echocardiography were recorded. ResultsThere were no statistical differences in age, gender, heart rate, body surface area, preoperative cardiac function (NYHA), left atrium dimension (LAD), left ventricular dimension (LVD), maximal long-axis of RA (RAmla), mid-RA minor distance (RAmmd), right ventricle dimension (RVD2), left ventricular ejection fraction (LVEF), left ventricular fractional shortening (LVFS) between the two groups (P>0.05). Six-months postoperative left atrial-ventricular diameter significantly reduced than that before surgery in the two groups (P<0.05). In the TAPG group, six-months postoperative right ventricle dimension (RVD1), right ventricular wall thickness (RVWT), tricuspid valve annular end-diastolic dimension (TVAEDD), tricuspid valve annular end-systolic dimension (TVAESD) significantly decreased, while percent shorting of tricuspid valve annulus (PSTVA) did not change significantly (P>0.05), TR degree improved significantly (P<0.05), right ventricular fractional area change (RVFAC) and right ventricular ejection fraction (RVEF) significantly increased (P<0.05). In the NTAPG group, compared with preoperative data, six-months postoperative RVD1, RVWT significantly increased, TVAEDD, TVAESD, PSTVA did not change significantly (P>0.05), RVEF reduced significantly (P<0.05), RVFAC increased significantly but less than that in the TAPG group at the same period, constituent ratio of TR changed significantly (P<0.05), but postoperative moderate or more TR were recorded in 6 patients. ConclusionConcomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent mitral valve replacement (MVR) can help to decrease RVD1, RVWT, TVAEDD and TVAESD, improve the constituent ratio of TR, and increase RVFAC and RVEF.
Objective To introduce a new type of bileaflet mechanical prosthetic heart valve (GK bileaflet valve)and evaluate clinically the early hemodynamic effect and short term follow-up after its replacement. Methods Sixty-one patients with heart valve diseases were operated upon. The mitral valve replacement was performed in 34 patients, aortic valve replacement in 16 patients and double valve replacement in 11 patients. A total of 72 GK bileaflet mechanical valves were implanted, 45 in mitral position, and 27 in aortic position. Blood consistency and hemodynamics were monitored. Follow-up was carried out routinely to check whether there were some valve-related complications. Results There was no early mortality (〈30 d). Only one patient died of trauma 2 months after the operation. Follow-up was 100% and extended 1 to 2. 5 years. Without valve-related complications all patients had lived for more than 1 to 2.5 years. In 98% (60/61) of survivors heart functional performance had improved to New York Heart Association class Ⅰ or Ⅱ . Conclusion Early clinical results and short term follow up demonstrate that GK bileaflet prosthetic heart valve exhibits excellent hemodynamic properties, satisfied blood consistency and a low incidence of valve-related complications. Midterm and long-term results should be observed further.
At present, interventional therapy for structural heart disease is in a period of vigorous development. Among them, transcatheter aortic valve replacement, as a representative of the interventional treatment of heart valve disease, has made rapid progress, which is a bright spot in the field of cardiovascular disease. The future development of transcatheter tricuspid valve repair/replacement is also promising. With the availability of important clinical evidence, the indications of transcatheter aortic valve replacement have been extended to the full risk range of severe aortic stenosis. More and more data showed that transcatheter mitral and tricuspid valve interventions could effectively alleviate patients’ symptoms and improve their prognosis. Transcatheter valve interventions have developed rapidly and have made tremendous progress in China. This article will review and interpret the important progress in the field of transcatheter valve interventions.
Objective To summarize the outcomes and clinical features for surgical treatment of nonischemic heart valve disease(HVD) combined with coronary artery disease(CAD), so that to get better surgical result. Methods From January 2000 to June 2007, 105 patients with the mean age of 61.96±7.61 years (range 36-79 years), underwent the combined procedures.The etiology of HVD included: 59 rheumatic valve disease, 24 degenerative mitral lesion, 13 calcified aortic valve lesion, and 9 other aortic valve disease. CAD was preoperatively diagnosed by coronary arteriongraphy in 98 patients, and intraoperatively identified in 7 patients. Left ventricular ejection fraction was 50% or less in 45 patients. The total number of bypass grafts was 216 with the mean of 2.06 grafts per patient. Valve procedures included: 36 mitral valve valve replacement, 15 mitral repair,43 aortic valve replacement, 11 mitral valve and aortic valve replacement. Results There were 6 postoperative deaths with the mortality of 5.7%. The causes of death were 3 low cardiac output syndrome, 2 renal failure, and 1 heart arrest resulting in multiple organs failure. Ninety-three survivals were followed up from 1 month to 7 years, 6 patients were missed on follow-up. There were no late death. New York Heart Association class Ⅰ was observed in 25 patients, class Ⅱ53, class Ⅲ 10 and class Ⅳ 5. One patient still had existential chest pain. Conclusion There were no typical angina in majority of patients with nonischemic HVD combined with CAD, coronary arteriongraphy must be taken in patients with the age of 50 years and more, or with the risk factors for CAD.Intraoperative myocardial protection is very important because CAD further deteriorates myocardial dysfunction caused by HVD.The decreased left ventricular function is the important factor affecting the surgical results and it is hard to evaluate the underlying cause before the operation.
Objective To evaluate the right ventricular function of the patients 2 years after surgery by ultrasonic cardiography (UCG) who underwent mitral valve replacement (MVR) concomitant tricuspid annuloplasty (TAP). Method We finally identified 36 patients required MVR with tricuspid valve annular dilation concomitant merely mild tricuspid regurgitaion (TR) based on preoperative UCG in our hospital between April and November 2012 year. All patients were randomly divided into two groups by digital table including a tricuspid annuloplasty group (a TAP group, n=18, 7 males and 11 females at age of 45.67±12.49 years) and a no-tricuspid annuloplasty group (a NTAP group, n=18, 6 males and 12 females at age of 45.44±10.48 years). General clinical data and extracorporeal circulation data were recorded. UCG evaluation was practiced preoperation, alone with 1 week, 6 months, and 2 years after surgery. Results Two years postoperative maximal long-axis of RA (RAmla), mid-RA minor distance (RAmmd), right ventricle dimension-1(RVD1) , right ventricular fractional area change (RVFAC), 3D RV end-systolic volume (3DRVESV), tricuspid valve annular end-diastolic dimension (TVAEDD), tricuspid valve annular end-systolic dimension (TVAESD) of patients were all smaller in the TAP group than those in the NTAP group. Yet right ventricular ejection fraction (RVEF), percent shorting of tricuspid valve annulus (PSTVA) were greater in the TAP group than those in the NTAP group, although there was no statistical difference between the two groups in two years postoperative 3D RV end-diastolic volume (3DRVEDV). The patients in the TAP group had a superior trend than that of the NTAP group. Moreover, the patients' TR constituent ratio in the TAP group was much better than that of the NTAP group in 2 year after operation. Conclusions Concomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent MVR is favorable for the recovery of their 2 years postoperative function of tricuspid valve and right ventricle. It is benefit to reduce patient's long term postoperative TR residues and exacerbation.
Objective To analyze the medium-and long-term r esults of tricuspid valve replacement(TVR), to summarize the experience in opera tive therapy for tricuspid valve disease. Methods From January 1998 to May 2006, sixty seven patients had undergone TVR. The etiology was rheumatic disease in 25 cases, congenital disease in 37 cases, degenerative disease in 1 case, infective endocarditis in 3 cases, a nd cardiac tumor in 1 case. All operations were performed under general anesthes i a and by cardiopulmonary bypass. Bioprostheses was replaced in 28 patients, whil e mechanical valve was replaced in 39 patients. Associated procedure included mi tral valve replacement in 13 cases, mitral valve replacement and aortic valve replac ement in 12 cases, repair of ventricular septal defect in 1 case, repair of atri al septal defect in 1 case, and radioablation of atrial fibrillation in 3 case s. Results The operative mortality was 11.94% (8/67),among these patients , 6 cases died of serious heart failure,1 case died of ventricular fibrillation, 1 case died of multi organ failure. During follow-up, 1 patient died of biopro thesis dysfunction 1 year after the operation, 1 patient died of cerebral emboli s m 6 years after the operation. Through statistical analysis, it showed that the mortality of TVR in rheumatic tricuspid valve disease was higher than that in co ngenital tricuspid valve disease [5.56%(2/36)vs. 24.00% (6/25); χ2=4.425 , P=0.036]; the mortality in second time operation was higher than that in first time operation [30.00%(3/10)vs. 8.77% (5/57);χ2=3.646,P=0.033 ]; while there was no significant difference in immediate and long-term result s with different choice of bioprosthetic or mechanical valve in TVR (χ2=0.002 , P=0.961). Conclusion Operative an d follow-up mortality is high in the TVR, valve replac ement is the last selection for the treatment of serious tricuspid disease, appr opriate operative technique and perioperative therapy is the key for success o f the operation.
Abstract: Objective To summarize the clinical experience of 13 patients of tricuspid valve replacement and to investigate the indication and method. Methods From January 1994 to December 2005, the clinical datum of the thirteen patients suffering from tricuspid valve disease were reviewed, including rheumatic heart disease 6 cases, congenital heart disease 3 cases, infective endocarditis 3 cases and right ventricular tumor 1 case. All the cases underwent tricuspid valve replacement. Results Two reoperative rheumatic heart disease patients died early after operation and their cardiac function was New York Heart Association (NYHA) class Ⅳ before operation. The followup interval was 3 months to 12 years in 11 cases. There were 2 late death, one died of recurrence of infective endocarditis, and another died of the recurrence of the tumor. One Ebstein anomaly case’s NYHA functional recovered to class Ⅲ, eight cases’s recovered to NYHA classⅠ-Ⅱ. Conclusion The tricuspid valve disease may be a secondary lesion from many causes. Indication of tricuspid valve replacement must be strictly commanded. The late results of tricuspid valve mechanical prostheses replacement is satisfactory.