• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "Heart valve" 48 results
    • Echocardiography Expression in Heart Valve Damage with Rheumatoid Arthritis

      【摘要】隨著超聲心動圖的普及與發展,無癥狀性類風濕性關節炎心臟瓣膜改變的檢出率逐漸增多。臨床應重視類風濕性關節炎心臟瓣膜損害以及超聲心動圖在這類疾病中的診斷價值,以期改善患者預后。【Abstract】 Objective More and more cardiac valve changes are detected in asymptomatic patients with rheumatoid arthritis by echocardiography. It is essential to pay attention to the clinical features of heart valves damage and the diagnostic value of echocardiography on that in order to improve the prognosis of patients.

      Release date:2016-09-08 09:45 Export PDF Favorites Scan
    • Self-management of Anticoagulation Monitoring for Patients Following Mechanical Heart Valve Replacement: A non-randomized Controlled Trial

      Objective To discuss the application value in increasing the frequency of monitoring and ensuring the safety of anticoagulation therapy in patient self-monitoring (PST) and self-management (PSM) of portable coagulometer. Method This non-randomized prospective controlled study was conducted in 100 patients receiving oral warfarin anticoagulation therapy after heart valve replacement and met the inclusion criteria in our hospital between March 2013 and April 2014 year. All the patients were divided into three groups including an outpatient follow-up group(outpatient group), a self-monitoring group and a self-management group. Meanwhile, the patients in the outpatient group visited professional institutions, performed international normalized ratio (INR) testing with central lab and adjusted the dosage of orally administered warfarin by the doctors. And the other two groups performed INR testing with CoaguChek XS portable coagulometer by themselves, and the patients in the self-management group performed management by themselves. The follow-up time was 6 months. The dates of time in therapeutic range (TTR), fraction of time in therapeutic range (FTTR) and anticoagulation complications in the three groups were analyzed and compared. Results There was no significant difference in the INR results obtained from the follow-up time among the three groups (P=0.845) . TTR value of INR of the outpatient group, the self-monitoring group, and the self-management group was 45.9% (4368.0 days/9517.0 days), 61.2% (6057.0 days/9897.0 days), and 65.4% (2833.8 days/4333.0 days), respectively with a statistical difference among the three groups (P<0.001) . FTTR value of INR obtained from the outpatient group, the self-monitoring group, and the self-management group was 48.3% (99 times/205 times), 60.7% (164 times/270 times), and 64.9% (100 times/154 times) respectively. There was a statistical difference in the FTTR between the outpatient group and the self-monitoring group (P=0.007) , and also between the outpatient group and the self-monitoring group (P=0.002) . But there was no statistical difference between the self-monitoring group and the self-management group (P=0.392) . There were not any major bleeding and thrombosis complications in all study. And there was no statistical difference in the total complications, thrombosis, and bleeding complications rates between the outpatient group and the self-monitoring group, and also between the outpatient group and the self-management group (P>0.05) . Conclusions The patients receiving oral anticoagulation after heart valve replacement or their care providers were able to perform PST and PSM. The use of portable coagulometer for self-monitoring and self-management can increase the frequency of anticoagulation monitoring and achieve better INR target value control. PST and PSM could achieve higher quality of anticoagulation management and life and without increasing the risk of oral anticoagulation than the traditional monitoring method. The monitoring frequency of once a month is reasonable for the patients receiving oral anticoagulation more than half a year after heart valve replacement.

      Release date: Export PDF Favorites Scan
    • Intermediateterm Results after Mechanical Valve Replacement in P atients Small Aortic Root

      Objective To observe the intermediate-term outcome and heart function in patients with small aortic root,and to investigate the feasi bility of small size prosthesis. Methods From July 1990 to Jun e 2003, 62 patients underwent 19mm aortic valve prosthesis(19mm group). The resu lts were compaired with other 62 patients receiving larger prosthesis(≥21 mm,21 mm group). Clinical symptoms, signs, electrocardiogram(ECG) and echocardiogr a phy (UCG) were followedup, KaplanMeier survival curve was used for analysis. Results In 19mm group, there were 38 patients with ≥Ⅱ/Ⅵ grade systolic murmur in aortic valve area,18 patients with ECG ST segm ent change and 11 patients with chest pain and/or chest distress. Postoperative cardiac function showed that 33 patients with heart function New York Heart Ass ociation(NYHA) class Ⅱ and 29 patients with NYHA class Ⅲ. Postoperative ECG sh owed in 21mm group,6 patients with ECG ST segment change,3 patients with chest distress and 6 patients with occasional chest pain and there were 48 patients with NYHA class Ⅱ and 14 patients with NYHA class Ⅲ,there was statis tically difference in heart function between two groups(P=0.020). Th ere was a significant regression of left ventricular end diastolic diameter(LVEDD),left ventricular wall thickness, mass index,and pressure gradients in both groups(P<0.05), and left ventricular ejection f raction (LVEF)had a significant increase in patients 5 years after operation tha n that before operation(P<0.05), and there was no statistically differenc e in both groups(P>0.05). Actual survival at 1,5 years were 93.5%,74 .2% in 19mm group compared with 95.2%,790% in the 21mm valve group, there were no statistically difference in both groups (P=0.231,0.110). Conc lus ion Patients with 19mm prosthetic aortic valves can experience a satisf actory improvement and get excellent intermediate-term survival.

      Release date:2016-08-30 06:09 Export PDF Favorites Scan
    • Study on the Physical Characteristics of Decellularized Porcine Pulmonary Valved Conduits Crosslinked by Carbodiimide

      Abstract: Objective To observe the physical characteristics of decellularized porcine pulmonary valved conduits crosslinked by carbodiimide (EDC). Methods [WTBZ]Twenty porcine pulmonary valved arteries were mobilized on relative asepsis condition. They were cut longitudinally into three samples at the junction position of pulmonary valve (every sample was comprised of a part of the pulmonary conduit wall and the corresponding valve). The samples were randomly divided into three groups by lotdrawing method. Group A was the control group which was made up of the fresh porcine arterial valved conduit samples without any other treatments. Group B was comprised of porcine pulmonary samples decellularized by trypsindetergent digestion. Group Cincluded the decellularized porcine pulmonary samples crosslinked by EDC. We observed the water content, thickness, tensile strength, and shrinkage temperature of all the samples, based on which the physical characeteristics of these samples were analyzed. Results [WTBZ]Complete cellfree-pulmonary conduit matrix was achieved by trypsindetergent digestion. Compared with group A, in group B, the water content of pulmonary wall was significantly higher (P=0.000), while the water content of pulmonary valve was not significantly different; the thickness of pulmonary wall and valve (P=0.000,0.000) and tensile strength of pulmonary wall and valve (Plt;0.01) was significantly lower, while shrinkage temperature was not significantly different. Compared with group B, in group C, the water content of pulmonary wall was significantly lower (P=0.000), while the water content of pulmonary valve, and the thickness of pulmonary wall and valve were not significantly different; the tensile strength of pulmonary wall (Plt;0.01) and valve (P=0.000), and the shrinkage temperature of them (P=0.000, 0.000) were significantly higher. Compared with group A, in group C, the water content of pulmonary wall and valve, and the tensile strength of them were not statistically different, while the thickness of pulmonary wall and valve was significantly lower (P=0.000, 0.000), and the shrinkage temperature of them was significantly higher (P=0.000, 0.000). Conclusion [WTBZ]EDC crosslinking method is available for treating decellularized porcine pulmonary valved conduits in order to enhance its tensile strength, and decrease water content of pulmonary wall.

      Release date:2016-08-30 05:57 Export PDF Favorites Scan
    • Concomitant Tricuspid Annuloplasty for Patients with Tricuspid Valve Annulus Dilation and Mild Tricuspid Regurgitation Underwent Mitral Valve Replacement: A Randomized Controlled Trial

      ObjectiveTo investigate effect of cardiac function and tricuspid regurgitation (TR) degree of concomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent mitral valve replacement (MVR), and provide an objective basis for clinical decision about concomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent MVR. MethodsA total of 36 patients who underwent MVR from April to October 2013 in Department of Cardiovascular Surgery, West China Hospital, Sichuan University were enrolled in this study. Preoperative echocardiography showed mild TR and tricuspid valve annular end-diastolic dimension (TVAEDD)/body surface area (BSA)>21 mm/m2. All the 36 patients were randomly divided into a tricuspid annuloplasty group (TAPG group, n=18, including 7 males and 11 females) and a no tricuspid annuloplasty group (NTAPG group, n=18, including 6 males and 12 females). One week and 6 months postoperative echocardiography were recorded. ResultsThere were no statistical differences in age, gender, heart rate, body surface area, preoperative cardiac function (NYHA), left atrium dimension (LAD), left ventricular dimension (LVD), maximal long-axis of RA (RAmla), mid-RA minor distance (RAmmd), right ventricle dimension (RVD2), left ventricular ejection fraction (LVEF), left ventricular fractional shortening (LVFS) between the two groups (P>0.05). Six-months postoperative left atrial-ventricular diameter significantly reduced than that before surgery in the two groups (P<0.05). In the TAPG group, six-months postoperative right ventricle dimension (RVD1), right ventricular wall thickness (RVWT), tricuspid valve annular end-diastolic dimension (TVAEDD), tricuspid valve annular end-systolic dimension (TVAESD) significantly decreased, while percent shorting of tricuspid valve annulus (PSTVA) did not change significantly (P>0.05), TR degree improved significantly (P<0.05), right ventricular fractional area change (RVFAC) and right ventricular ejection fraction (RVEF) significantly increased (P<0.05). In the NTAPG group, compared with preoperative data, six-months postoperative RVD1, RVWT significantly increased, TVAEDD, TVAESD, PSTVA did not change significantly (P>0.05), RVEF reduced significantly (P<0.05), RVFAC increased significantly but less than that in the TAPG group at the same period, constituent ratio of TR changed significantly (P<0.05), but postoperative moderate or more TR were recorded in 6 patients. ConclusionConcomitant tricuspid annuloplasty for patients with tricuspid valve annulus dilation and mild TR underwent mitral valve replacement (MVR) can help to decrease RVD1, RVWT, TVAEDD and TVAESD, improve the constituent ratio of TR, and increase RVFAC and RVEF.

      Release date: Export PDF Favorites Scan
    • In vitro experience in tissue engineering heart valve with poly-hydroxybutyrate-co-hydroxyvalerate

      Objective To evaluate the feasibility to fabricate tissue engineered heart valve leaflet with poly hydroxybutyrate co hydroxyvalerate (PHBV) scaffold. Methods Constructive characteristics of PHBV were observed by scanning electron microscope. PHBV was implanted subcutaneously in rabbit and extirpated at 2,4,6,8, and 10 weeks in order to study its biocompatibility and biodegradability. Cell growth curve, smooth muscle α actin and ultra microscopic characteristics were observed in canine aortic valve interstitial cells. The cells were seeded on the PHBV and their function of prostaglandin I 2 (PGI 2) synthesis was determined. Results Porous diameter of PHBV was 130μm, PHBV had good biocompatibility and completely degraded at the end of the 10th week. Smooth muscle α actin were expressed in canine aortic valve interstitial cells and grew well. Cells implanted on PHBV grew well, PGI 2 were synthesized and secreted( P lt;0.05). Conclusion It is feasible to fabricate a tissue engineering heart valve leaflet in vitro with PHBV scaffold.

      Release date:2016-08-30 06:27 Export PDF Favorites Scan
    • Mid-term results of surgical treatment for prosthetic valve endocarditis

      Objective To analyze the mid-term results of surgical treatment for prosthetic valve endocarditis (PVE). Methods We retrospectively analyzed the clinical data of 22 PVE patients operated in our institution from January 2006 to June 2016. There were 14 males and 8 females, aged 31-62 (49.6±11.8) years. PVE occurred following single valve replacements in 20 patients, including aortic valve replacements in 12 and mitral valve replacements in 8. Two patients suffered PVE after multi-valve replacement, which was aortic and mitral valves. Mechanical valves were used in all patients. Early PVE (<1 year after valve implantation) was detected in 10 patients, and late PVE (>1 year after valve implantation) in 12 patients. Blood culture was negative in 6 patients. Fifteen patients underwent emergent or urgent surgery (within one week after definite diagnosis) and 7 elective surgery. Paravalvular abscess was detected in 12 patients and repaired bovine pericardium. Results Three patients (13.6%) died postoperatively in hospital, among whom two died of multiple systemic organ failure, and the other died of cerebral hemorrhage. Main postoperative complications included low cardiac output syndrome in 5 patients (22.7%), renal dysfunction in 6 (27.3%), respiratory failure in 5 (22.7%) and pulmonary infection in 4 (18.2%). During the follow-up of 6-120 (53.6±20.8) months, 2 deaths were observed in the middle term, including one sudden death and the other of cerebral infarction. No recurrent infection or valve-related surgery was observed during the follow-up. The survival rate was 86.4% in 1 year and 70.4% in 5 years. Conclusion PVE is a very severe disease with high mortality. Early surgical treatment and complete removal of infectious tissues have preferable early- and mid-term results.

      Release date:2017-09-04 11:20 Export PDF Favorites Scan
    • Discussion on quality control in clinical trials of interventional valvular medical devices

      With the rapid development of the field of interventional therapy of cardiac valve, the innovative researches of interventional therapy of cardiac valve products have become the focus of global research. At present, there is a serious shortage of interventional valvular medical devices on the market in China, and large-scale interventional valve products are undergoing early human trials or confirmatory clinical trials. The effective quality control of clinical trials is of great significance to ensure that clinical trial data can be used to support the marketing of device products. By analyzing the problems in clinical trials quality control of interventional valvular medical devices in our hospital, and combining the characteristics of device products and diseases, we explore the key points of quality control and provide reference for the implementation and completion of high-quality clinical trials.

      Release date:2023-08-31 05:57 Export PDF Favorites Scan
    • Nursing Experience of Glycemic Control for Patients with Rheumatic Heart Disease Combined with Diabetes after Valve Replacement

      ObjectiveTo summarize the monitoring experiences of blood glucose for patients with rheumatic heart disease combined with diabetes, in order to prevent postoperative complications caused by abnormal blood sugar, relieve pain and promote rehabilitation. MethodsWe reviewed the medical records of the patients with diabetes after heart valve replacement who were admitted to our department from April 2011 to March 2012. Eighty patients were randomly divided into observation group and control group with 40 in each group. Patients in the control group received conventional treatment with subcutaneous insulin injection, while the observation group patients were treated with intravenous insulin pump, and the dose of insulin was adjusted depending on blood glucose levels. Then we compared the postoperative changes in blood glucose level and complications between the two groups. ResultsThe insulin dose, the time of reaching target blood glucose levels, hospital stays and postoperative complication rates were significantly lower in the observation group than the control group (P<0.05). During the one-year follow-up after operations, 2 and 4 patients died respectively in the observation group and the control group, and the difference was not significant (χ2=0.180, P=0.670). ConclusionFor patients with diabetes after heart valve replacements, intravenous insulin pump is better than subcutaneous insulin injection. It can prevent complications, shorten hospital stays, reduce financial burden, and promote prognosis and harmonious doctor-patient relationship.

      Release date: Export PDF Favorites Scan
    • Cryomaze ablation procedure for atrial fibrillation concomitant with valve surgery

      Objective To summarize safety and effectiveness of cryomaze ablation procedure concomitant with valve surgery. Methods We retrospectively investigated the clinical data of 62 patients (24 males and 38 females) with mean age of 49.4±14.2 years who underwent cryomaze ablation procedure concomitant with valve surgery in our hospital from August 2013 through July 2015. The heart rhythm of the patients after surgery was supervised by 12-leads electrical cardiogram respectively. Results The rate of sinus rhythm restored right after surgery was 98.4%. The rate of sinus rhythm restored at the time of discharge was 93.4%. The rate of sinus rhythm restored 3 months, 6 months, 12 months, 18 months after surgery was 90.2%, 87.3%, 85.0%, 83.3% respectively. The one-year post-operation rate of sinus rhythm restored for the group of right minimal invasive thoracoscopic assisted mitral valve surgery was 90.5%. Longer duration for atrial fibrillation (>7 years) was a risk factor for the reoccurrence of atrial fibrillation 1 year after surgery (P<0.05). Conclusion Cryomaze ablation procedure concomitant with valve surgery is quite effective in treatment of rheumatic valve disease and atrial fibrillation. This approach is associated with fewer complications, comparable atrial fibrillation reoccurrence for short-term follow-up.

      Release date:2017-04-24 03:51 Export PDF Favorites Scan
    5 pages Previous 1 2 3 4 5 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南