• <table id="gigg0"></table>
  • west china medical publishers
    Author
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Author "DONG Zhihui" 3 results
    • Multi slice CT spiral and MRI Performance of Spinal Giant Cell Tumor (6 Cases’ Reports)

      目的:明確脊柱骨巨細胞瘤的多層螺旋CT、MRI表現。方法:回顧性分析經病理證實的脊柱骨巨細胞瘤6例(男5例,女1例,年齡21~40歲,平均32歲)。6例CT檢查,3例有MRI檢查。結果:發生于胸椎3例,腰椎1例,骶椎2例。CT主要表現為膨脹性溶骨性破壞和較大軟組織腫塊;MRI表現T1加權成像為低等信號,T2加權成像為高低混雜信號特點,可顯示瘤內壞死、囊變、出血等。結論:脊柱骨巨細胞瘤具有侵襲性強、生長活躍、易復發等特點,結合CT、MRI檢查可對該病做出及時診斷,且對臨床分期、手術方案制訂及術后定期隨訪有重要價值。

      Release date:2016-09-08 10:01 Export PDF Favorites Scan
    • Finite element simulation of stent implantation and its applications in the interventional planning for hemorrhagic cardio-cerebrovascular diseases

      Numerical simulation of stent deployment is very important to the surgical planning and risk assess of the interventional treatment for the cardio-cerebrovascular diseases. Our group developed a framework to deploy the braided stent and the stent graft virtually by finite element simulation. By using the framework, the whole process of the deployment of the flow diverter to treat a cerebral aneurysm was simulated, and the deformation of the parent artery and the distributions of the stress in the parent artery wall were investigated. The results provided some information to improve the intervention of cerebral aneurysm and optimize the design of the flow diverter. Furthermore, the whole process of the deployment of the stent graft to treat an aortic dissection was simulated, and the distributions of the stress in the aortic wall were investigated when the different oversize ratio of the stent graft was selected. The simulation results proved that the maximum stress located at the position where the bare metal ring touched the artery wall. The results also can be applied to improve the intervention of the aortic dissection and the design of the stent graft.

      Release date:2021-02-08 06:54 Export PDF Favorites Scan
    • Stent Graft Induced New Entry after Thoracic Endovascular Aortic Repair——Insight from Biomechanical Injury by Stent Graft

      ObjectiveTo analyze the causes and preventions of stent graft induced new entry (SINE) after thoracic endovascular aortic repair (TEVAR) for Stanford type B dissection, particularly from the standpoint of biomechanical behavior of stent graft. MethodsSINE was defined as the new tear caused by the stent graft itself, excluding those arising from natural disease progression or any iatrogenic injury from the endovascular manipulation. Twentytwo patients with SINE were retrospectively collected and analyzed out of 650 cases undergoing TEVAR for type B dissection from August 2000 to June 2008 in our center. An additional case included was referred to our center in 14 months after TEVAR performed in another hospital. ResultsTotally, there were 24 SINEs found in 23 cases, including SINE at the proximal end in 15 cases, at the distal end in 7, and at both in 1, and 6 patients died. The incidence was 3.4% ( 22/650) in our hospital, and the mortality was 26.1% (6/23). All 16 proximal SINEs was located at the greater curve of the arch and caused retrograde type A dissection. All 8 distal SINEs occurred at the dissected flap, and 5 of them caused enlarging aneurysm while 3 remained stable. All 23 cases had the endograft placed across the distal aortic arch during the primary TEVAR. ConclusionsSINE is not rare following TEVAR for type B dissection, and associates with a high substantial mortality. The stress yielded by the endograft seems to play a predominant role in its occurrence. It is of significance to take the stressinduced injury into account during both design and placement of the endograft.

      Release date:2016-09-08 10:45 Export PDF Favorites Scan
    1 pages Previous 1 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南