    • Application of a new point contact pedicle navigation template as an auxiliary screw implant in scoliosis correction surgery

      ObjectiveTo explore the effectiveness of a new point contact pedicle navigation template (referred to as “new navigation template” for simplicity) in assisting screw implantation in scoliosis correction surgery. MethodsTwenty-five patients with scoliosis, who met the selection criteria between February 2020 and February 2023, were selected as the trial group. During the scoliosis correction surgery, the three-dimensional printed new navigation template was used to assist in screw implantation. Fifty patients who had undergone screw implantation with traditional free-hand implantation technique between February 2019 and February 2023 were matched according to the inclusion and exclusion criteria as the control group. There was no significant difference between the two groups (P>0.05) in terms of gender, age, disease duration, Cobb angle on the coronal plane of the main curve, Cobb angle at the Bending position of the main curve, the position of the apical vertebrae of the main curve, and the number of vertebrae with the pedicle diameter lower than 50%/75% of the national average, and the number of patients whose apical vertebrae rotation exceeded 40°. The number of fused vertebrae, the number of pedicle screws, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were compared between the two groups. The occurrence of implant complications was observed. Based on the X-ray films at 2 weeks after operation, the pedicle screw grading was recorded, the accuracy of the implant and the main curvature correction rate were calculated. ResultsBoth groups successfully completed the surgeries. Among them, the trial group implanted 267 screws and fused 177 vertebrae; the control group implanted 523 screws and fused 358 vertebrae. There was no significant difference between the two groups (P>0.05) in terms of the number of fused vertebrae, the number of pedicle screws, the pedicle screw grading and accuracy, and the main curvature correction rate. However, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were significantly lower in trial group than in control group (P<0.05). There was no complications related to screws implantation during or after operation in the two groups. ConclusionThe new navigation template is suitable for all kinds of deformed vertebral lamina and articular process, which not only improves the accuracy of screw implantation, but also reduces the difficulty of operation, shortens the operation time, and reduces intraoperative bleeding.

      Release date:2023-06-07 11:13 Export PDF Favorites Scan
    • Effectiveness of guide plate with mortise-tenon joint structure combined with off-axis fixation in treatment of Pauwels type Ⅲ femoral neck fractures

      Objective To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures. Methods A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups (P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation. Results Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant (P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group (P<0.05), the incision was significantly longer (P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups (P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups (P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups (P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups (P<0.05). There was no significant difference between the two plate groups (P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups (P>0.05). Conclusion For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.

      Release date:2025-03-14 09:43 Export PDF Favorites Scan
    • Effectiveness of endovascular repair with fenestration stent and branch stent assisted by 3D printing in treating thoracoabdominal aortic aneurysm involving visceral artery area

      ObjectiveTo evaluate the clinical value of in vitro fenestration and branch stent repair in the treatment of thoracoabdominal aortic aneurysm in visceral artery area assisted by 3D printing.MethodsThe clinical data of 7 patients with thoracoabdominal aortic aneurysm involving visceral artery at the Department of Vascular Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University from March 2016 to May 2019 were analyzed retrospectively. There were 5 males and 2 females with an average age of 70.2±3.9 years. Among them 4 patients had near-renal abdominal aortic aneurysm, 3 had thoracic aortic aneurysm, 4 had asymptomatic aneurysm, 2 had acute symptomatic aneurysm and 1 had threatened rupture of aneurysm. According to the preoperative CT measurement and 3D printing model, fenestration technique was used with Cook Zenith thoracic aortic stents, and branch stents were sewed on the main stents in vitro, and then the stents were modified by beam diameter technique for intracavitary treatment.ResultsAll the 7 patients completed the operation successfully, and a total of 18 branch arteries were reconstructed. The success rate of surgical instrument release was 100.0%. The average operation time was 267.0±38.5 min, the average intraoperative blood loss was 361.0±87.4 mL and the average hospital stay was 16.0±4.2 d. Immediate intraoperative angiography showed that the aneurysms were isolated, and the visceral arteries were unobstructed. Till May 2019, there was no death, stent displacement, stent occlusion, ruptured aneurysm or loss of visceral artery branches. Conclusion3D printing technology can completely copy the shape of human artery, intuitively present the anatomical structure and position of each branch of the artery, so that the fenestration technique is more accurate and the treatment scheme is more optimized.

      Release date:2022-01-21 01:31 Export PDF Favorites Scan
    • Evaluation specification of CT images for transapical transcatheter aortic valve replacement

      According to the needs of CT image evaluation for transapical transcatheter aortic valve replacement (TAVR), 20 clinical questions were proposed by the Delphi method, 15 questions were initially determined, and 12 clinical questions were summarized and determined by domestic experts. PubMed, Web of Science, Wanfang, and CNKI databases were searched by computer to collect the relevant literature from inception to November 2022, and finally 53 studies were included. Based on evidence-based study and evaluation experience, 3 meetings were held to give recommendations for preoperative CT data acquisition method, preoperative imaging evaluation of aortic root, imaging evaluation of transapical approach, preoperative auxiliary guidance of TAVR by CT images combined with 3D printing, and postoperative imaging evaluation of transapical TAVR, hoping to promote the standardized and successful development of transapical TAVR in China.

      Release date:2023-05-09 03:11 Export PDF Favorites Scan
    • COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS

      ObjectiveTo study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. MethodsOne adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. ResultsAccording to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. ConclusionCustomized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.

      Release date: Export PDF Favorites Scan
    • RESEARCH PROGRESS OF ADIPOSE-DERIVED STEM CELLS COMPOUND WITH THREE DIMENSIONAL PRINTING SCAFFOLD FOR ENGINEERED TISSUE

      ObjectiveTo review the research progress of adipose-derived stem cells (ADSCs) compound with three dimensional (3D) printing scaffold in tissue engineering of fat, bone, cartilage, blood vessel, hepatocyte, and so on. MethodsThe recently published literature about ADSCs compound with 3D printing scaffold in tissue engineering at home and abroad was reviewed, analyzed, and summarized. ResultsA large number of basic researches showed that ADSCs could differentiate into a variety of tissues on 3D printing scaffold and involve in tissue repair and regeneration. But there is still a long way between the basic theory and the clinical practice at the early stages of development. ConclusionIt can effectively improve and restore the structure and function of the damaged tissue and organ to use ADSCs and 3D printing scaffold.

      Release date: Export PDF Favorites Scan
    • 3D打印技術輔助復雜主動脈夾層腔內治療

      目的探討3D打印技術對復雜主動脈夾層(Stanford B型)腔內治療的術前評估的可行性和有效性。 方法獲取Stanford B型主動脈夾層CT數據,3D打印主動脈夾層關注部分;3D打印模型術前評估。 結果3D打印模型不僅能夠準確輔助選擇主動脈支架,而且能夠評估支架不同位置導致的主動脈弓形變情況,從而輔助手術方案選擇。 結論3D打印技術輔助復雜解剖條件的主動脈夾層腔內治療方案選擇是可行有效的方式。

      Release date: Export PDF Favorites Scan
    • Effectiveness evaluation of three-dimensional printed customized hemi-pelvic prosthesis for pelvic reconstruction after resection of massive pelvic tumor

      Objective To investigate the effectiveness of three-dimensional (3D) printed customized hemi-pelvic prosthesis for pelvic reconstruction after resection of massive pelvic tumors. Methods A retrospective analysis was conducted on 26 patients with massive pelvic tumors who met the selection criteria and were treated between November 2021 and May 2025. The cohort included 11 males and 15 females, with a mean age of 52.65 years (range, 17-73 years). Histopathological diagnoses were as follows: 9 cases of chondrosarcoma, 2 of undifferentiated pleomorphic sarcoma, 4 of spindle cell sarcoma, 2 of osteosarcoma, 1 of solitary fibrous tumor, 1 of myxoid chondroma, 1 of malignant peripheral nerve sheath tumor, 1 of chondromyxoid epithelioma, and 5 of metastatic malignant tumors. According to the Enneking classification, tumor involvement was distributed as 4 cases in zones Ⅰ+Ⅱ, 9 in zones Ⅱ+Ⅲ, 3 in zones Ⅰ+Ⅳ, 8 in zones Ⅰ+Ⅱ+Ⅲ, and 2 in zones Ⅰ+Ⅱ+Ⅳ. The disease duration ranged from 3 to 40 months, with a mean of 9.85 months. All patients underwent reconstruction with customized 3D-printed hemi-pelvic prostheses. The effectiveness was evaluated by Musculoskeletal Tumor Society (MSTS) score and Harris hip score before operation and at last follow-up, and pain levels were evaluated by visual analogue scale (VAS) score before operation, at 3 months after operation, and at last follow-up. ResultsThe operation time ranged from 186 to 528 minutes, with a mean of 334.58 minutes. The intraoperative blood loss ranged from 1 400 to 4 000 mL, with a mean of 2173.08 mL, and the transfusion volume ranged from 750 to 3 500 mL, with a mean of 1 659.62 mL. All 26 patients were followed up 10-42 months (mean, 18.5 months). Postoperative complications included prosthetic dislocation in 2 cases, which were attributed to improper positioning during home care and an accidental fall, respectively. One patient developed a vesicocutaneous fistula and poor wound healing due to pre-existing tumor invasion into the bladder. One patient experienced failure and loosening of the internal fixation at 8 months after operation caused by local tumor recurrence, and subsequently died at 14 months postoperatively due to progression of brain metastases. Postoperative complications such as poor healing of incisions, prosthetic dislocation, or failure of internal fixation were not observed in the remaining patients. At last follow-up, the walking ability of most patients recovered to varying degrees. The VAS scores at 3 months and at last follow-up significantly improved when compared with those before operation, and the scores at last follow-up further improved when compared with 3 months after operation, all showing significant differences (P<0.05). The MSTS scores and Harris scores at last follow-up were significantly higher than those before operation (P<0.05). Conclusion 3D printed customized hemi-pelvic prosthesis is effective for reconstruction of massive pelvic tumors after resection, but there are still some limitations, and soft tissue reconstruction should be paid attention to.

      Release date: Export PDF Favorites Scan
    • Effectiveness comparison of anterior cervical discectomy and fusion with zero-profile three-dimensional-printed interbody fusion Cage and titanium plate fusion Cage

      Objective To compare the effectiveness of a zero-profile three-dimensiaonal (3D)-printed microporous titanium alloy Cage and a conventional titanium plate combined with a polyether-ether-ketone (PEEK)-Cage in the treatment of single-segment cervical spondylotic myelopathy (CSM) by anterior cervical discectomy and fusion (ACDF). Methods The clinical data of 83 patients with single-segment CSM treated with ACDF between January 2022 and January 2023 were retrospectively analyzed, and they were divided into 3D-ZP group (35 cases, using zero-profile 3D-printed microporous titanium alloy Cage) and CP group (48 cases, using titanium plate in combination with PEEK-Cage). There was no significant difference in gender, age, disease duration, surgical intervertebral space, and preoperative Japanese Orthopaedic Association (JOA) score, visual analogue scale (VAS) score, neck disability index (NDI), vertebral height at the fusion segment, Cobb angle, and other baseline data between the two groups (P>0.05). The operation time, intraoperative blood loss, hospital stay, complications, interbody fusion, and prosthesis subsidence were recorded and compared between the two groups. VAS score, NDI, and JOA score were used to evaluate the improvement of pain and function before operation, at 3 months after operation, and at last follow-up, and the vertebral height at the fusion segment and Cobb angle were measured by imaging. The degree of dysphagia was assessed by the Bazaz dysphagia scale at 1 week and at last follow-up. Results The operation was successfully completed in all the 83 patients. There was no significant difference in intraoperative blood loss and hospital stay between the two groups (P>0.05), but the operation time in the 3D-ZP group was significantly shorter than that in the CP group (P<0.05). Patients in both groups were followed up 24-35 months, with an average of 25.3 months, and there was no significant difference in the follow-up time between the two groups (P>0.05). The incidence and grade of dysphagia in CP group were significantly higher than those in 3D-ZP group at 1 week after operation and at last follow-up (P<0.05). There was no dysphagia in 3D-ZP group at last follow-up. There was no complication such as implant breakage or displacement in both groups. The intervertebral fusion rates of 3D-ZP group and CP group were 65.71% (23/35) and 60.42% (29/48) respectively at 3 months after operation, and there was no significant difference between the two groups [OR (95%CI)=1.256 (0.507, 3.109), P=0.622]. The JOA score, VAS score, and NDI significantly improved in the 3D-ZP group at 3 months and at last follow-up when compared with preoperative ones (P<0.05), but there was no significant difference between the two groups (P>0.05). There was no significant difference in the improvement rate of JOA between the two groups at last follow-up (P>0.05). At 3 months after operation and at last follow-up, the vertebral height at the fusion segment and Cobb angle significantly improved in both groups, and the two indexes in 3D-ZP group were significantly better than those in CP group (P<0.05). At last follow-up, the incidence of prosthesis subsidence in 3D-ZP group (8.57%) was significantly lower than that in CP group (29.16%) (P<0.05). ConclusionThe application of zero-profile 3D-printed Cage and titanium plate combined with PEEK-Cage in single-segment ACDF can both reconstruct the stability of cervical spine and achieve good effectiveness. Compared with the latter, the application of the former in ACDF can shorten the operation time, reduce the incidence of prosthesis subsidence, and reduce the incidence of dysphagia.

      Release date:2025-09-01 10:12 Export PDF Favorites Scan
    • 胸壁外科的精準與微創醫療

      Release date:2023-08-31 05:57 Export PDF Favorites Scan