• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "Cornea" 20 results
    • Changes of corneal nerve fiber and the correlation analysis with visual acuity in demyelinating optical neuritis patients

      ObjectiveTo investigate the changes in the nerve fiber layer of the cornea in patients with demyelinating optic neuritis (DON) and its correlation with visual acuity. MethodsA cross-sectional study. From March 2021 to July 2022, 27 cases (39 eyes) of DON patients diagnosed in the Department of Neurology and Ophthalmology of Beijing Tongren Hospital Affiliated to Capital Medical University were enrolled in this study. According to the serological test results, the patients were divided into aquaporin 4 antibody associated optic neuritis (AQP4-ON group) and myelin oligodendrocyte glycoprotein antibody associated optic neuritis (MOG-ON group), with 15 cases (19 eyes) and 12 cases (20 eyes) respectively. According to previous history of glucocorticoid treatment, the patients were divided into glucocorticoid treated group and non-glucocorticoid treated group, with 17 cases (27 eyes) and 10 cases (12 eyes) respectively. Twenty healthy volunteers (20 eyes) with age- and gender-matched were selected as the control group. All eyes underwent best corrected visual acuity (BCVA) and in vivo confocal microscopy (IVCM) examinations. BCVA was performed using Snellen's standard logarithmic visual acuity chart, which was converted into logarithmic minimum angle resolution (logMAR) visual acuity during statistics. The corneal nerve fiber length (CNFL), corneal nerve fiber density (CNFD), corneal nerve fiber branch length (CNBL), corneal nerve fiber branch density (CNBD) and the density of corneal dendritic cells (DC) were detected by IVCM examination. Parameter comparison between groups by t-test and Kruskal-Wallis rank sum test. The correlation between logMAR BCVA and pamameters of corneal nerve fibers were analyzed using Spearman analysis. ResultsThe CNFL, CNFD, and CNBL of the DON group and the control group were (10.67±2.55) mm/mm2, (57.78±12.35) root/mm2, (3.27±1.34) mm/mm2, and (13.74±3.05) mm/mm2, (70.95±13.14) root/mm2, and (4.22±1.03) mm/mm2, respectively; the difference in CNFL, CNFD, and CNBL between the two groups were statistically significant (t=4.089, 3.795, 2.773; P<0.05). The CNFL, CNBL, and CNBD of the affected eyes in the MOG-ON group and AQP4-ON group were (12.02±2.13) mm/mm2, (3.80±1.19) mm/mm2, (47.97±8.86) fibers/mm2, and (9.25±2.19) mm/mm2, (2.72±1.19) mm/mm2, (39.43±13.86) fibers/mm2, respectively; the differences in CNFL, CNBL, and CNBD between the two groups were statistically significant (t=-4.002, -2.706, -2.306; P<0.05). The corneal DC density of the patients in the hormone treated group and the non-hormone treated group was (24.43±8.32) and (41.22±9.86) cells/mm2, respectively. The difference in corneal DC density between the two subgroups was statistically significant (P<0.001). Correlation analysis showed that there was a significant negative correlation between logMAR BCVA and CNBL and CNFL in patients with DON (r=-0.422, -0.456; P<0.05). ConclusionsThere are different degrees of corneal nerve fiber damage in patients with different types of DON. There was a negative correlation between BCVA and the length of corneal nerve fibers.

      Release date:2023-05-18 10:05 Export PDF Favorites Scan
    • The effects on rabbit corneas and retinas after single intravitreal injection of voriconazole at different doses

      Objective To observe the effects on rabbit corneas and retinas after single intravitreal injection of voriconazole at different doses. Methods According to the randomization table, 25 healthy rabbits were randomly divided into control group, and voriconazole 50, 100, 200, and 400 μg groups. Therefore, there were 5 rabbits in each group. The eyes of control group received intravitreal injection of 0.1 ml balanced saline solution, and those treatment groups received 0.1 ml voriconazole injection of corresponding dose. Before the injection and 1, 7, and 14 days after the injection, endothelial cell counts and corneal thicknesses were measured; full-field electroretinogram were performed and b-wave amplitudes in maximal combined reaction (Max-R) were recorded. On 14 days after the injection, histologic structures were observed by light microscope and transmission electron microscope. Results There was no significant difference in endothelial cell counts (F=0.320, 0.291, 0.467, 0.649) and corneal thicknesses (F=0.214, 0.284, 0.360, 0.225) with those of control group at any time points (P > 0.05). Before and 1 day after the injection, b-wave amplitudes of each voriconazole group had no significant difference compared with those of control group (F=0.220, 0.106; P > 0.05). On 7 days after the injection, b-wave amplitudes decreased significantly at doses of 200 μg and 400 μg (P < 0.05). On 14 days after the injection, there was no significant difference between the the amplitude of 200 μg group and that of control group (P > 0.05). However, the amplitude of the 400 μg group decreased continuously and there was still significant difference (P < 0.05). Light microscopy did not reveal any corneal abnormality in both control group and voriconazole groups. The retinas were normal except that of the 400 μg group, which hadathinner and degenerated inner nuclear layer and disordered photoreceptor layer. Under transmission electron microscope, there were no ultrastructure damages of corneas in both control group and voriconazole groups, either. The rabbit retinas of the 50 μg and 200 μg group have normal inner nuclear layer and photoreceptor layer, but degrees of changes in both layers were observed in the eyes of 200 μg and 400 μg group. Conclusions There is no obvious effects on rabbit corneas and retinas after single intravitreal injection of voriconazole at he dose less than or equal 100 μg. There are no obvious effects on rabbit corneas at the dose of 200 μg and 400 μg, while there are damages to the retinas in both functions and histological structures.

      Release date: Export PDF Favorites Scan
    • RESEARCH ADVANCE OF CORNEAL TISSUE ENGINEERING

      Objective To review research progress of corneal tissueengineering.Methods The recent articles on corneal tissue engineering focus on source and selection of corneal cells, the effects of growth factors on culture of corneal cells in vitro. The preparation and selection of three-dimensional biomaterial scaffolds and their b and weak points were discussed. Results The corneal tissue engineering cells come from normal human corneal cells. The embryo corneal cell was excellent. Several kinds of growth factors play important roles in culture, growth and proliferation of corneal cell, and incroporated into matrix.Growth factors including basic fibroblast growth factor, keratinocyte growth factor, transforming growth factor β1 and epidermal growth factor was favor to corneal cell. Collagen, chitosan and glycosaninoglycans were chosen as biomaterial scaffolds. Conclusion Human tissue engineering cornea can be reconstructed and transplanted. It has good tissue compatibility and can be used as human corneal equivalents.

      Release date: Export PDF Favorites Scan
    • Glaucoma and anterior chamber angle changes after intravitreal silicone oil injection for complicated retinal detachment

      Objective To evaluate glaucoma and anterior chamber angle changes after intravitreal silicone oil injection(SOI). Methods The intraocular pressure(IOP) and anterior chamber angles of 34 e yes(33 patients)undergone pars plana vitrectomy and SOI were observed. Results Glaucoma occurred in 9 eyes(26%),in which silicone oil glaucoma(SOG) accounted for 77%(7/9).The changes of the superior part of anterior chamber angle were peripheral anterior synechiae in 11 eye(32%) and SO emulsification droplets in 22 eyes(64%) in 1~4.5 months after surgeries.Glaucoma occurred in 6 eyes of 7 eyes undergone peripheral iridectomy at the inferio r part of the iris after the closure of iridectomy holes (plt;0.05). Conclusion High incidence of glaucoma was found in this series of patients after intravitreal silicone oil injection,and the main causes of SOG were closure of the inferior iridecomy hole and silicone emulsification. (Chin J Ocul Fundus Dis, 2001,17:105-107)

      Release date:2016-09-02 06:03 Export PDF Favorites Scan
    • Characterization of rabbit corneal biomechanical properties after corneal refractive surgery based on rapid loading-unloading uniaxial tensile test

      In order to understand how the biomechanical properties of rabbit cornea change over time after corneal ablation, 21 healthy adult rabbits were used in this study, with the left eye as experimental side and the right eye as the control side. Firstly, a lamellar knife was used to remove a portion of the anterior corneal surface tissue (30%~50% of the original corneal thickness) from the left eye of each rabbit, as an animal model simulating corneal refractive surgery. Secondly, postoperative experimental rabbits were kept for one, three, or six months until being euthanized. Strip specimens were produced using their corneas in vitro to perform a uniaxial tensile test with an average loading-unloading rate of approximately 0.16 mm/s. Finally, the visco-hyperelastic material constitutive model was used to fit the data. The results showed that there was a significant difference in the viscoelastic parameters of the corneas between the experimental and the control eyes at the first and third postoperative months. There was a difference in tangential modulus between the experimental and the control eyes at strain levels of 0.02 and 0.05 at the third postoperative month. There was no significant difference in biomechanical parameters between the experimental and the control eyes at the sixth postoperative month. These results indicate that compared with the control eyes, the biomechanical properties of the experimental eyes vary over postoperative time. At the third postoperative month, the ratio of corneal tangential modulus between the experimental and the control eyes significantly increased, and then decreased. This work lays a preliminary foundation for understanding the biomechanical properties of the cornea after corneal refractive surgery based on rapid testing data obtained clinically.

      Release date:2024-04-24 09:40 Export PDF Favorites Scan
    • DIFFERENTIATION OF ADIPOSE-DERIVED MESENCHYMAL STEM CELLS AFTER TRANSFECTION WITH Pax6 GENE

      ObjectiveTo investigate the feasibility of adipose-derived mesenchymal stem cells (ADMSCs) differentiating into corneal epithelium-like cells after transfection with Pax6 gene. MethodsThe adipose tissue from bilateral inguinal of healthy C57BL/6 mice (5-6 weeks old) was used to isolate and culture ADMSCs.The 3rd passage ADMSCs were subjected to treatments of non-transfection (group A),pcDNA3.1 empty vector transfection (group B),and recombinant plasmid of pcDNA3.1-Pax6 transfection (group C),respectively.At 48 hours after transfection,the cells in groups B and C were selected with G418.The cell morphology changes were observed under the inverted microscope.Pax6 protein and level of corneal epithelial cells specific molecular-cytokeratin 12 (CK-12) were measured by Western blot.Real-time fluorescence quantitative PCR was applied to measure the mRNA expression of CK-12. ResultsNo morphology change was observed in groups A and B.Two different cell clones were found in group C.No.1 selected clone showed a flagstone-like appearance that was similar to that of corneal epithelial cells;No.2 selected clone showed a net-like appearance,with 3-7 cell processes.The Western blot results showed the Pax6 protein expression in 2 clones of group C,but no expression in groups A and B; and CK-12 protein expression was only observed in No.1 selected clone of group C,and no expression in the others.The real-time fluorescence quantitative PCR results showed that the CK-12 mRNA expression level of No.1 selected clone of group C was 8.64±0.73,which was significantly higher than that of No.2 selected clone of group C (0.55±0.42),group B (1.36±0.40),and group A (1.00±0.00) (P<0.05),and there was no significant difference among groups A,B and No.2 selected clone of group C (P>0.05). ConclusionPax6 gene transfection could induce differentiation of ADMSCs into corneal epithelium-like cells which express CK-12 at both the mRNA and protein levels.This result provides a promising strategy of generating corneal epithelilcm-like cells for construction of tissue engineered cornea.

      Release date: Export PDF Favorites Scan
    • Clinical observation of photodynamic therapy for vitelliform macular dystrophy with choroidal neovascularization

      Objective To observe the efficacy of photodynamic therapy for vitelliform macular dystrophy(VMD) with choroidal neovascularization(CNV). Methods The clinical data of 7 patients (7 eyes) of VMD with CNV who had undergone photodynamic therapy (PDT) were retrospectively analyzed. The patients were 4 males and 3 females, aged from 20 to 54 years. The patients received the examinations of best corrected visual acuity (BCVA), slitlamp microscopy, fundus photography, fluorescein angiography (FFA), indocyanine green angiography (ICGA), spectral domain OCT(SD-OCT), electrooculogram(EOG)and electroretinogram (ERG)before and after PDT. The BCVA ranged from finger counting to 0.6. Retinal edema and the subretinal fluid were observed. The mean thickness of central retina was (506.00plusmn;30.71) mu;m. PDT was performed according to the standard treatment. The follow-up period ranged from 2 to 11 months with the mean of 6.3 months. The changes of BCVA, CNV and side effects were observed after treatment. Results BCVA improved in all patients ranging from 0.12 to 1.0. The regression of the CNV and resolution of the subretinal fluid were observed by FFA, ICGA and SD-OCT after PDT. The mean thickness of central retina was reduced to (401.00plusmn;52.22) mu;m. There was no PDTassociated ocular or systemic side effect. Conclusions PDT is an effective and safe treatment for VMD with CNV. It may improve or stabilize the visual acuity. 

      Release date:2016-09-02 05:37 Export PDF Favorites Scan
    • PHOTOCHEMICAL TISSUE BONDING TECHNIQUE FOR REPAIRING LIMBAL STEM CELL DEFICIENCY

      Objective?To investigate the feasibility of photochemical tissue bonding (PTB) technique in repairing limbal stem cell (LSC) deficiency and the effect on cornea wound healing.?Methods?LSCs were isolated from limbus of New Zealand rabbits by tissue block culture method, and then the LSCs of 2nd passage were cultured on de-epithelialized human amniotic membrane (HAM) for 3 weeks to prepare the HAM/LSC grafts. The LSC deficiency models of the left eyes were established by 0.5 mol/L NaOH in 24 New Zealand female rabbits, aged 3-4 months and weighing 1.5-2.0 kg. HAM/LSC grafts were used to repair the cornea wounds by sutures (suture group, n=12) or by PTB technique (PTB group, n=12). The gross was observed including the corneal transparency, erythema, and new blood vessel formation after surgery. At 3 and 28 days, the inflammatory cytokine of interleukin 1β (IL-1β), IL-6, and tumor necrosis factor α (TNF-α) were assayed by ELISA method; and the amount of new blood vessels were quantified by immunohistochemistry staining at 28 days.?Results?All animals survived to the end of the experiment. At 3 days, there was no obvious difference in the corneal transparency between 2 groups; at 28 days, the corneal transparency of PTB group was higher than that of suture group, and new blood vessels decreased. HE staining showed that mass inflammatory cells infiltrated between graft and cornea basal layer at 3 days, and no new blood vessel formed. inflammatory cells infiltration significantly decreased at 28 days in PTB group; the amount of new blood vessels was (2.0 ± 0.8)/ HP in PTB group and was (6.3 ± 1.3)/HP in suture group, showing significant difference (t=7.966, P=0.002). At 28 days, the concentrations of inflammatory cytokine of IL-1β, IL-6, and TNF-α in suture group were significantly higher than those in PTB group (P lt; 0.05); however, no significant differences were observed between 2 groups at 3 days (P gt; 0.05).?Conclusion?PTB technique can be used to fix HAM/LSC grafts, which can decrease inflammatory cell infiltration and new vessel formation, and improve the outcomes when compared with suture technique.

      Release date:2016-08-31 05:45 Export PDF Favorites Scan
    • Effects of long-term orthokeratology on astigmatism and corneal topography

      ObjectiveTo investigate whether the corneal shape recovered after discontinuation of long-term orthokeratology and whether orthokeratology increased the corneal astigmatism and ocular astigmatism.MethodsFrom December 2016 to April 2018, a retrospective study was conducted on 33 myopic patients who had undergone two times standard orthokeratology in the outpatient department of West China Hospital of Sichuan University, and had stopped wearing the first orthokeratology lens for one month before fitting the second orthokeratology lens. A total of 32 myopia frame glasses wearers were selected by simple random sampling as control. The changes of corneal flat meridian curvature (flat K), corneal steep meridian curvature (steep K), corneal astigmatism and ocular astigmatism before and after discontinuation of orthokeratology were analyzed.ResultsAmong the patients with baseline myopia diopter of ?0.25~?2.75 D, the average annual change of corneal flat K was (?0.03±0.21) D in the frame glasses group and (?0.24±0.14) D in the orthokeratology group, the difference was statistically significant (t=5.555, P<0.001). Among the patients with baseline myopia diopter of ?0.25~?2.75 D, the average annual change of corneal steep K was (0.20±0.42) D in the frame glasses group and (0.15±0.20) D in the orthokeratology group, the difference was not statistically significant (t=0.785, P=0.435). Among the patients with baseline myopia diopter of ?3.00~?5.75 D, the average annual change of corneal steep K was (0.29±0.39) D in the frame glasses group and (?0.01±0.20) D in the orthokeratology group, the difference was statistically significant (t=2.758, P=0.014). The average changes of corneal astigmatism were analyzed according to the difference of eyes, gender, age and baseline corneal astigmatism, the difference was not statistically significant (P>0.05), respectively. For patients with baseline astigmatism absolute value less than or equal to 0.50 D, the astigmatism annual change of the frame glasses group was 0.00 (0.50) D, and that of orthokeratology group was ?0.33 (0.48) D, the difference was statistically significant (Z=?2.301, P=0.021).ConclusionsThe flat K of the cornea becomes flatter and the steep K does not change after one month’s discontinuation of long-term orthokeratology. There was no difference in the increase of corneal astigmatism compared with those wearing frame glasses. When the baseline ocular astigmatism is less than or equal to 0.50 D, the increase of astigmatism may occur after discontinuation of orthokeratology.

      Release date:2020-08-25 09:57 Export PDF Favorites Scan
    • Effects of SMILE with different residual stromal thicknesses on corneal biomechanical properties of rabbits in vivo

      Femtosecond laser small incision lenticule extraction (SMILE) with different residual stromal thicknesses (RST) is set to investigate its effect on corneal biomechanical properties of rabbits in vivo. In this study, 24 healthy adult Japanese rabbits were randomly divided into group A and B. The RST of group A was set 30% of the corneal central thickness (CCT), and the RST of group B was 50% of the CCT. The thickness of the corneal cap in both groups was set one third of CCT. Corneal visualization Scheimpflug technology (Corvis ST) and Pentacam three-dimensional anterior segment analyzer were used to determine corneal biomechanical and morphological parameters before surgery, and 1 week, 1 month and 3 months after surgery. Pearson correlation analysis was used to analyze factors affecting corneal biomechanical parameters after SMILE. The results showed that the corneal stiffness of group A was significantly higher than that of group B at 1 week and 1 month after surgery, and most biomechanical parameters returned to preoperative levels at 3 months postoperatively. The results of correlation analysis showed that postoperative CCT and RST were the main factors affecting corneal biomechanical parameters after SMILE. There was no significant difference in corneal posterior surface height (PE) between 3 months after surgery and before surgery in both two groups. It indicates that although the ability to resist deformation of cornea decreases in SMILE with thicker corneal cap and less RST, there is no tendency to keratoconus, which may be related to the preservation of more anterior stromal layer.

      Release date:2022-10-25 01:09 Export PDF Favorites Scan
    2 pages Previous 1 2 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南