• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "CT angiography" 18 results
    • Effectiveness of pulmonary artery CT angiography and pulmonary embolism findings based on artificial intelligence

      Objective To explore the application value of artificial intelligence (AI) pulmonary artery assisted diagnosis software for suspected pulmonary embolism patients. Methods The data of 199 patients who were clinically suspected of pulmonary embolism and underwent pulmonary artery CT angiography (CTA) from June 2016 to December 2021 were retrospectively analyzed. Images of pulmonary artery CTA diagnosed by radiologists with different experiences and judged by senior radiologists were compared with the analysis results of AI assisted diagnostic software for pulmonary artery CTA, to evaluate the diagnostic efficacy of this software and low, medium, and senior radiologists for pulmonary embolism. The agreement of pulmonary embolism based on pulmonary artery CTA between the AI software and radiologists with different experiences was evaluated using Kappa test. Results The agreement of the AI software and the evaluation of pulmonary embolism lesions by senior radiologists based on pulmonary artery CTA was high (Kappa=0.913, P<0.001), while the diagnostic results of pulmonary artery CTA AI software was good after judged by senior radiologists based on pulmonary artery CTA (Kappa=0.755, P<0.001). Conclusions The AI software based on pulmonary artery CTA diagnosis of pulmonary embolism has good consistency with diagnostic images of radilogists, and can save a lot of reconstruction and diagnostic time. It has the value of daily diagnosis work and worthy of clinical promotion.

      Release date:2024-02-22 03:22 Export PDF Favorites Scan
    • Clinical Application of Multi-Slice Spiral CT in Portal Vein Imaging

      Objective To study the clinical significance of multi-slice spiral CT in portal vein imaging. Methods One hundred and thirty seven cases underwent enhanced scan with GE Light SpeedQX/i4 CT scanner were collected, including 41 cases of liver cancer, 20 cases of hepatic cirrhosis, 21 cases of cavernous hemangioma of liver, 9 cases of hepatic abscess, 6 cases of carcinoma of gallbladder, 14 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 5 cases in normal. The results of portal vein images were reconstructed with three-dimensional software and analyzed. Results In 109 cases, portal vein, cranial mesenteric vein, and splenic vein were demonstrated successfully in the stage of portal vein: volume rendering images were clear in 84 cases, and maximum intensity projection images and multiplanar reconstruction images were clear in 109 cases. Forty-five cases of portal hypertension, 18 cases of opened collateral circulation, 15 cases of portal vein tumor thrombus, 1 case of splenic vein tumor thrombus, and 6 cases of large cavernous hemangioma were demonstrated successfully. Conclusion The portal vein imaging with multi-slice spiral CT can show the dissection and lesions of portal vein and its branches clearly, and can provide the clinical evidence for clinicians to formulate a treatment plan correctly.

      Release date:2016-09-08 10:49 Export PDF Favorites Scan
    • LENGTHENED PEDICLE OF RECTUS ABDOMINIS FLAP TO REPAIR DEFECT ON NECK AND CHEST

      ObjectiveTo explore the feasibil ity to repair defect on the neck and chest with the rectus abdominis flap which pedicle is lengthened by measuring the width, thickness, and the intercostal space of the inferior costicartilage using CT angiography (CTA). MethodsThirty cases receiving CTA and three-dimensional reconstruction between July and December 2013 were included in the study. Of 30 cases, 17 were male and 13 were female, aged 44-70 years (mean, 56 years). The width and thickness of the 3rd to 7th costicartilages and the distance of the 3rd to 6th intercostal spaces were measured, and the lengthened pedicle was calculated after the 4th to 7th costicartilage was cut off. Between July 2012 and November 2013, the lengthened pedicle of the rectus abdominis flap was cl inically used to repair the defect on the neck and chest in 4 cases. ResultsThe pedicle of the rectus abdominis flap was about 6 cm in length. When the left 7th, 6th, 5th, and 4th costicartilages were cut off, the average pedicle was lengthened by 4.07, 7.99, 12.50, and 17.48 cm respectively; when the right 7th, 6th, 5th, and 4th costicartilages were cut off, the average pedicle was lengthened by 4.63, 10.82, 16.64, and 22.05 cm respectively. In 4 flaps which were cl inically used to repair defects, 3 flap completely survived, 1 flap had partial necrosis. Three patients were followed up 6 months, and the appearance and texture of the flap were satisfactory; 1 patient failed to be followed up. ConclusionResecting the inferior costicartilage can prolong the pedicle of the rectus abdominis flap, therefore it can be used to repair defect on the upper chest and the neck.

      Release date: Export PDF Favorites Scan
    • Control Study on the Value of Head Boneless CT Angiography for Surface Shaded Display and Volume Computed Tomographic Digital Subtraction Angiography in Diagnosing Intracranial Aneurysms

      ObjectiveTo investigate the value of head boneless CT angiography (CTA) for surface shaded display (SSD) (hereinafter referred to as the SSD-CTA technology) and volume computed tomographic digital subtraction angiography (VCTDSA) in diagnosing intracranial aneurysms. MethodsWe collected the clinical data of 35 patients diagnosed to have intracranial aneurysm by VCTDSA between April 2013 and November 2014 from the First Affiliated Hospital of Chongqing Medical University. The original data were imported into the CT workstation of the First People's Hospital of Chengdu. Then, SSD-CTA technology was performed for bone reconstruction. We compared the results of these two technologies. In addition, we selected another 27 patients diagnosed with intracranial aneurysm by SSDCTA and DSA examination at the same time between June 2012 and November 2014 in the First People's Hospital of Chengdu for comparison. ResultsThe quality score of SSD-CTA reconstructed image was lower than that of VCTDSA, but the diagnosis of the two technologies for intracranial aneurysm was not statistically different (P>0.05). Compared with DSA, the sensitivity and specificity of the diagnosis for intracranial aneurysms by SSD-CTA were both 100%. ConclusionSSD-CTA is valuable in diagnosing intracranial aneurysms.

      Release date: Export PDF Favorites Scan
    • A comparative study of color Doppler ultrasound and CT angiography for preoperative evaluation of perforator vessels in free posterior interosseous artery flap

      Objective To investigate the accuracy of color Doppler ultrasound (CDU) and CT angiography (CTA) in the preoperative evaluation of perforator vessels in free posterior interosseous artery perforator (PIAP) flaps. Methods Between January 2020 and December 2023, 19 patients with hand skin and soft tissue defects caused by trauma were admitted. There were 11 males and 8 females, with a median age of 45 years (range, 26-54 years). The interval between injury and admission was 5-11 days (mean, 7.2 days). The skin and soft tissue defects were located on the dorsum of the hand in 8 cases and on the fingers in 11 cases. The size of defect ranged from 4.0 cm×2.5 cm to 7.5 cm×3.5 cm. After locating the perforator vessels through CDU and CTA before operation, the free PIAP flaps were designed to repair hand defects, with the size of 4.5 cm×3.0 cm-7.5 cm×4.0 cm. The defects of donor sites were directly sutured. The number and diameter of perforator vessels in the posterior interosseous artery detected by CDU and CTA were compared. The differences in localization of perforator vessels using CDU and CTA and their clinical effects were also compared to calculate the accuracy and recognition rate. During follow-up, the survival of the skin flap was observed, and the Vancouver scar scale (VSS) score was used to evaluate the healing of the donor site, while the visual analogue scale (VAS) score was used to evaluate the patient’s satisfaction with the appearance of the skin flap. Results The number and the diameter of PIAP vessels was 5.8±1.2 and (0.62±0.08) mm assessed by CDU and 5.2±1.0 and (0.60±0.07) mm by CTA, showing no significant difference between the two methods (P>0.05). The number, course, and distribution of perforator vessels of the PIAP vessels observed during operation were basically consistent with those detected by preoperative CDU and CTA. Compared with intraoperative observation results, the recognition rates of dominant perforating vessels by CDU and CTA were 95.0% (18/19) and 89.5% (17/19), respectively, and the accuracy rates were 100% (19/19) and 84.2% (16/19), with no significant difference between the two methods (P>0.05). All flaps survived after operation, and all wounds and incisions at donor sites healed by first intention. All patients were followed up 6-13 months (mean, 8.2 months). At last follow-up, the skin flaps had elasticity and soft texture, with the patient satisfaction VAS score of 9.2±0.8. The donor sites had no obvious scar hyperplasia with the VSS score of 11.7±0.9. Conclusion CDU and CTA accurately identify the dominant perforator vessels and provide reliable information for vessel localization, facilitating precise flap harvesting and minimizing donor site injury. However, CDU offers superior visualization of distal end of perforator vessels in the forearm compared to CTA.

      Release date: Export PDF Favorites Scan
    • THREE-DIMENSIONAL VISUALIZATION RECONSTRUCTION OF MEDIAL SURAL ARTERY PERFORATOR FLAP based on Digital technology

      ObjectiveTo explore the feasibility of three-dimensional (3-D) visualization reconstruction of the medial sural artery perforator flap based on digital technology. MethodsA series of Dicom images were obtained from three healthy adult volunteers by dual source CT angiography. Then the Mimics software was used to construct the medial sural artery model and measure the indexes, including the starting position of medial sural artery, external diameters of vascular pedicle, the number of perforators, location perforated deep fascia, and the maximum pedicle length of perforators based on medial sural artery perforator flap. ResultsThe 3-D visualization reconstruction models were successfully finished with Mimics software, which can clearly display the distribution, travel, and perforating point. Thirteen perforators were found in 6 legs, which started at the popliteal artery with a mean external diameter of 2.3 mm (range, 1.9-2.7 mm). Each specimen had 1-3 perforators, which located at the site of 6.2-15.0 cm distal to popliteal crease and 2.5-4.2 cm from posterior midline. The maximum pedicle length of medial sural artery perforator flap was 10.2-13.8 cm (mean, 11.8 cm). ConclusionThe 3-D visualization reconstruction models based on digital technology can provide dynamic visualization of the anatomy of the medial sural artery for individualized design of the medial sural artery perforator flap.

      Release date: Export PDF Favorites Scan
    • Ultrasonographic characteristics of renal artery involvement in acute Stanford type A aortic dissection and its relationship with renal function: A retrospective cohort study

      Objective To investigate the ultrasonographic characteristics of acute Stanford type A aortic dissection (ATAAD) involving the renal arteries and their relationship with renal function. Methods Patients with ATAAD admitted to Deyang People's Hospital from February 2013 to May 2023 were selected for the study. Based on whether the renal arteries were involved in the dissection, the patients were divided into two groups: a renal artery involvement group and a renal artery non-involvement group. General data and ultrasound characteristics of the two groups were compared. Logistic regression analysis and model correction were performed to analyze the relationship between ultrasound characteristics and renal function involvement in ATAAD patients. Receiver operating characteristic (ROC) curves were used to evaluate the predictive value of ultrasound characteristics for renal artery involvement in ATAAD patients. Additionally, patients in the renal artery involvement group were divided into normal renal function and abnormal renal function subgroups based on serum blood urea nitrogen (BUN) and serum creatinine (Scr) levels. Clinical data of the two subgroups were compared, and a log-binomial model was used to analyze the risk effects of ultrasound characteristics for abnormal renal function. Pearson correlation analysis was performed to assess the correlation between ultrasound characteristics of renal artery involvement and renal function indicators. Results A total of 163 patients were included, consisting of 106 males and 57 females, with a mean age of (50.06±10.46) years (ranging from 20 to 85 years). Significant differences in gender, Scr, and BUN were observed between the renal artery involvement group and the renal artery non-involvement group (P<0.001). Compared to the renal artery non-involvement group, the renal artery involvement group had an increased ascending aorta diameter, a greater proportion of ascending aortic dilation and poor renal perfusion (P<0.05). Logistic regression analysis indicated that ascending aorta diameter, ascending aortic dilation, and poor renal perfusion were independent factors for renal artery involvement (P<0.05). Ultrasonographic characteristics showed good predictive ability for renal artery involvement in ATAAD patients. Furthermore, the combination of the three characteristics yielded a higher predictive value for renal artery involvement. Compared to the normal renal function group, the abnormal renal function group had higher BUN and Scr levels, increased ascending aortic diameter, a greater proportion of ascending aortic dilation and poor renal perfusion (P<0.05). The log-binomial model analysis revealed that the risk ratios for ascending aortic diameter, ascending aortic dilation, and poor renal perfusion were statistically significant both before and after adjustment (P<0.05). Pearson correlation analysis revealed that ascending aortic diameter, ascending aortic dilation, and poor renal perfusion were strongly correlated with renal function parameters (P<0.05). ConclusionUltrasound characteristics of ATAAD involving the renal arteries are associated with renal function. Ascending aorta diameter, ascending aortic dilation, and poor renal perfusion are independent risk factors for abnormal renal function.

      Release date:2025-04-02 10:54 Export PDF Favorites Scan
    • The effect of axis pedicle and intra-axial vertebral artery on C2 pedicle screw placement

      Objective To investigate the influence of axis pedicle and intra-axial vertebral artery (IAVA) alignment on C2 pedicle screw placement by measuring the data of head and neck CT angiography. MethodsThe axis pedicle diameter (D), isthmus height (H), isthmus thickness (T), and IAVA alignment types were measured in 116 patients (232 sides) who underwent head and neck CT angiography examinations between January 2020 and June 2020. Defined the IAVA offset direction by referencing the vertical line through the center of C3 transverse foramen on the coronal scan, it was divided into lateral (L), neutral (N), and medial (M). Defined the IAVA high-riding degree by referencing the horizontal line through the outlet of the C2 transverse foramen, it was divided into below (B), within (W), and above (A). The rate of pedicle stenosis, high-riding vertebral artery, and different IAVA types were calculated, and their relationships were analysed. Simulative C2 pedicle screws were implanted by Mimics 19.0 software, and the interrelation among the rates of pedicle stenosis, high-riding vertebral artery, IAVA types, and vertebral artery injury were analyzed. ResultsThe rate of C2 pedicle stenosis was 33.6% (78/232), and the rate of high-riding vertebral artery was 35.3% (82/232). According to the offset direction and the degree of riding, IAVA was divided into 9 types, among which the N-W type (29.3%) was the most, followed by the L-W type (19.0%) and the L-B type (12.9%), accounting for 60.9%. The vertebral artery injury rate of simulative implanted C2 pedicle screws was 35.3% (82/232). The vertebral artery injury rate in patients with pedicle stenosis and high-riding vertebral artery was significantly higher than that who were not (P<0.001). The rate of pedicle stenosis, high-riding vertebral artery, and vertebral artery injury were significantly different among IAVA types (P<0.001), and M-A type was the most common. ConclusionVertebral artery injury is more common in pedicle stenosis and/or high-riding vertebral artery and/or IAVA M-A type. Preoperative head and neck CT angiography examination has clinical guiding significance.

      Release date:2022-08-04 04:33 Export PDF Favorites Scan
    • High-riding vertebral artery and its influence on upper cervical spine surgery

      In the variation of vertebral artery in artery groove, high-riding vertebral artery is the most common. High-riding vertebral artery can affect the choice of internal fixation device for upper cervical spine surgery, and may lead to serious complications such as vertebral artery injury and even death. In recent years, great progress has been made in the concept, incidence, diagnostic techniques, classification and impact on upper cervical spine surgery of high-riding vertebral artery. This review summarizes the above contents in order to improve clinicians’ understanding of high-riding vertebral artery, and provide a reference for timely diagnosis of high-riding vertebral artery, make an appropriate plan for upper cervical cervical spine surgical fixation, and reduce surgical complications.

      Release date:2020-11-25 07:18 Export PDF Favorites Scan
    • Application of digital technology in superficial lateral sural artery perforator flap for tiny hand wounds reconstruction

      Objective To investigate the effectiveness of the digital technology in repairing tiny hand wounds with superficial lateral sural artery perforator flap. Methods Between August 2013 and October 2016, 10 cases of tiny hand wounds were treated with the superficial lateral sural artery perforator flap. There were 6 males and 4 females, aged 19 to 47 years (mean, 31.2 years). The causes included crushing injury by machine in 6 cases, traffic accident injury in 3 cases, and electric burning injury in 1 case. The location of the soft tissue defect was the first web in 2 cases, the thumb pulp in 3 cases, the index finger pulp in 1 case, the dorsal palms in 3 cases, and the dorsum of finger in 1 case. The time from injury to hospitalization was 4 hours to 10 days (mean, 3.5 days). The size of wound was from 4 cm×3 cm to 8 cm×7 cm. All defects were associated with exposure of tendon and bone. CT angiography (CTA) from aortaventralis to bilateral anterior and posterior tibial arteries was performed before operation, and the appropriate donor site as well as perforator was selected. Then the CTA data were imported into the Mimics15.0 software to reconstruct the three dimensional structure of the perforator artery, bone, and skin; according to flap size, the flap design and harvesting process were simulated. The flap was obtained on the basis of preoperative design during operation. The size of flaps varied from 5 cm×4 cm to 10 cm×8 cm. The donor site was sutured directly in 9 cases and repaired with skin grafting in 1 case. Results Superficial medial sural artery peforator was cut in 3 patients whose superficial lateral sural artery was too narrow, and the flaps were obtained to repair defects smoothly in the others. Venous crisis occurred in 1 flap, which survived after exploration of the vessel, thrombus extraction, and thrombolysis; the other flaps survived successfully. All wounds and incisions healed by first intention. All cases were followed up 3-18 months (mean, 10 months). The flaps had good shape. At last follow-up, the results were excellent in 6 cases, good in 3 cases, and fair in 1 case according to total active motion (TAM). Conclusion The preoperative individualized design of the superficial lateral artery perforator flap can realize through CTA digital technology and Mimics15.0 software; it can reduce the operation risk and is one of better ways to repair the tiny hand wounds.

      Release date:2017-05-05 03:16 Export PDF Favorites Scan