• <table id="gigg0"></table>
  • west china medical publishers
    Keyword
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Keyword "Artificial" 239 results
    • Diagnostic value of artificial intelligence-assisted diagnostic system for pulmonary cancer based on CT images: A systematic review and meta-analysis of 4 771 patients

      ObjectiveTo evaluate the diagnostic value of artificial intelligence (AI)-assisted diagnostic system for pulmonary cancer based on CT images.MethodsDatabases including PubMed, The Cochrane Library, EMbase, CNKI, WanFang Data and Chinese BioMedical Literature Database (CBM) were electronically searched to collect relevant studies on AI-assisted diagnostic system in the diagnosis of pulmonary cancer from 2010 to 2019. The eligible studies were selected according to inclusion and exclusion criteria, and the quality of included studies was assessed and the special information was identified. Then, meta-analysis was performed using RevMan 5.3, Stata 12.0 and SAS 9.4 softwares. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio were pooled and the summary receiver operating characteristic (SROC) curve was drawn. Meta-regression analysis was used to explore the sources of heterogeneity.ResultsTotally 18 studies were included with 4 771 patients. Random effect model was used for the analysis due to the heterogeneity among studies. The results of meta-analysis showed that the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnosis odds ratio and area under the SROC curve were 0.87 [95%CI (0.84, 0.90)], 0.89 [95%CI (0.84, 0.92)], 7.70 [95%CI (5.32, 11.15)], 0.14 [95%CI (0.11, 0.19)], 53.54 [95%CI (30.68, 93.42)] and 0.94 [95%CI (0.91, 0.95)], respectively.ConclusionAI-assisted diagnostic system based on CT images has high diagnostic value for pulmonary cancer, and thus it is worthy of clinical application. However, due to the limited quality and quantity of included studies, above results should be validated by more studies.

      Release date:2021-10-28 04:13 Export PDF Favorites Scan
    • FABRICATION OF TISSUE ENGINEERED SKIN EQUIVALENT

      OBJECTIVE: To fabricate artificial human skin with the tissue engineering methods. METHODS: The artificial epidermis and dermis were fabricated based on the successful achievements of culturing human keratinocytes(Kc) and fibroblasts (Fb) as well as fabrication of collagen lattice. It included: 1. Culture of epidermal keratinocytes and dermal fibroblasts: Kc isolated from adult foreskin by digestion of trypsin-dispase. Followed by comparison from aspects of proliferation, differentiation of the Kc, overgrowth of Fb and cost-benefits. 2. Fabrication of extracellular matrix sponge: collagen was extracted from skin by limited pepsin digestion, purified with primary and step salt fraction, and identified by SDS-PAGE. The matrix lattice was fabricated by freeze-dryer and cross-linked with glutaraldehyde, in which the collagen appeared white, fibrous, connected and formed pores with average dimension of 180 to 260 microns. 3. Fabrication artificial human skin: The artificial skin was fabricated by plating subcultured Kc and Fb separately into the lattice with certain cell density, cultured for one week or so under culture medium, then changed to air-liquid interface, and cultured for intervals. RESULTS: The artificial skin was composed of dermis and epidermis under light microscope. Epidermis of the skin consisted of Kc at various proliferation and differentiation stages, which proliferated and differentiated into basal cell layer, prickle cell layer, granular layer, and cornified layer. Conifilament not only increased in number, but also gathered into bundles. Keratohyalin granules at different development stages increased and became typical. The kinetic process of biochemistry of the skin was coincide with the changes on morphology. CONCLUSION: Tissue engineered skin equivalent has potential prospects in application of repairing skin defect with advantages of safe, effective and practical alternatives.

      Release date:2016-09-01 10:21 Export PDF Favorites Scan
    • EXPERIMENTAL STUDY ON EFFECT OF PLATELET-RICH PLASMA IN REPAIR OF BONE DEFECT

      OBJECTIVE: To study the effect of platelet-rich plasma in the repair of bone defect. METHODS: Segmental bone defects of 1 cm were created in the mid-upper part of bilateral radius of 24 New Zealand white rabbits. One side was randomly chosen as the experimental side, which was filled with artificial bone with platelet-rich plasma (PRP). The other side filled with artificial bone without PRP as the control. After 2, 4, 8 and 12 weeks of implantation, the gross, radiological, histological observations, and computer graphic analysis were performed to investigate the bone healing of the defect in both sides. RESULTS: Two weeks after operation, new bone and fibrous tissue formation in both the experimental and the control sides were observed only in the areas adjacent to the cut ends of the host bone, but the amount of new tissue in the experimental side was much more than that in the control side. In the 4th and 8th weeks, the surface of the artificial bone was covered with a large amount of new bones, the artificial bone was bridged tightly with the host bone by callus in the experimental side, while new bone was limited mainly in the cut ends and was less mature in the control side. In the 12th weeks, bone defects were entirely healed in the experimental side, which were covered completely with cortical bone, while new bone formation was only observed in the ends of artificial bone and there were not continuous bone callus on the surface in the control side. CONCLUSION: Artificial bone with PRP is effective in the repair of segmental bone defects, and PRP could improve the healing of bone defect.

      Release date:2016-09-01 09:35 Export PDF Favorites Scan
    • Analysis of current hot issues about cardiopulmonary resuscitation

      Cardiopulmonary resuscitation (CPR) is a very important treatment after cardiac arrest. The optimal treatment strategy of CPR is uncertain. With the accumulation of clinical medical evidence, the CPR treatment recommendations have been changed. This article will review the current hot issues and progress, including the pathophysiological mechanisms of CPR, how to achieve high-quality chest compression, how to achieve CPR quality monitoring, how to achieve optimal CPR for different individuals and how to use antiarrhythmic drugs.

      Release date:2019-12-12 04:12 Export PDF Favorites Scan
    • COMPARISON BETWEEN FOUR-STRAND SEMITENDINOSUS TENDON AUTOGRAFT AND LIGAMENTADVANCED REINFORCEMENT SYSTEM FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION BYARTHROSCOPY

      【Abstract】 Objective To compare the therapeutic effect of anterior cruciate l igament (ACL) reconstruction bymeans of four-strand semitendinosus tendon autograft and l igament advanced reinforcement system (LARS) by arthroscopy. Methods From July 2002 to April 2005, 42 patients underwent ACL reconstruction by arthroscopy. Twenty-seven patients were treated by four-strand semitendinosus tendon autograft (semitendinosus tendon autograft group), including 22 males and 5 females, with the age from 20 years to 52 years. Among these patients, there were 12 sports injuries, 8 traffic accidents and 7 other injuries. There were 16 cases of left knees and 11 of right knees. The pre-operation Lysholm score was 50.70 ± 6.68, and the course of the disease was 2 to 12 months. Other 15 patients were treated by LARS artificial l igament (LARS group), including 12 males and 3 females, with the age from 17 years to 40 years. Among these patients, there were 8 sports injuries, 4 traffic accidents and 3 other injuries. There were 6 cases of left knees and 9 of right knees. The pre-operation Lysholm score was 50.20 ± 6.22, and the course of the disease was 3 to 12 months. There was no statistically significant difference between the two groups (P gt; 0.05). The ranges of motion, stabil ity and compl ication of the knee were evaluated during the follow-up. Results All incisions healed at the first stage. The patients in the semitendinosus tendon autograft group were followed up for 22 months to 43 months, while 18 months to 40 months in the LARS group. There were 5 patients (19%) whose tensile gap was more than3 mm when the max tensile force text was done in the semitendinosus tendon autograft group, and 3 patients (20%) in the LARS group. The Lysholm score was 87.80 ± 3.41 in the semitendinosus tendon autograft autograft group, and 88.90 ± 3.30 in the LARS group. There was no statistically significant difference between the two groups (P gt; 0.05). The final evaluation based on the improved Lysholm classification standard showed the choiceness rate was 92.6% (18 excellent cases, 7 good cases and 2 faircases) in the semitendinosus tendon autograft group, and 93.3% (11 excellent cases, 3 good cases, 1 fair case) in the LARS group. There was no statistically significant difference between the two groups (P gt; 0.05). The joint motion capabil ity evaluation, according to the Tegner standard, showed 3 to 6 class (with the average class of 4.93) in the semitendinosus tendon autograft group, and 3 to 7 class (with the average class of 5.03) in the LARS group. There was no statistically significant difference (P gt; 0.05). The knee extension in 2 cases was 5° less than the normal, and in 5 cases 5-10° less than the normal in the semitendinosus tendon autograft group. But in all cases in the LARS group, joint motion recovered to the normal (P lt; 0.05). There was no sign of synovitis in both groups. Conclusion The recent cl inical result of ACL reconstruction with the four-strand semitendinosus tendon autograft or LARS artificial l igament by arthroscopy is satisfactory without significant difference. LARS can shorten the recovery time without compl ications such as synovitis in 2-year follow-up.

      Release date:2016-09-01 09:12 Export PDF Favorites Scan
    • APPLICATION OF ARTIFICIAL HUMERAL HEAD IN THE TREATMENT OF TUMOR OF UPPER END OF HUMERUS

      In order to restore the function of shoulder joint in patient with tumor of upper end of humerus, artificial humeral head replacement was performed. The materials included resinene, nylon-6 and large molecular polyethylene from 1978 to 1993, 14 patients were treated. The tumors involved in this group were giant cell tumor, synviosarcoma, bone cyst, osteochondroma, osteoblastoma, osteofibrosarcoma, osteosarcoma, chondrosarcoma, parosteosarcoma and malignant giant cell tumor. After resection of the tumor, the artificial prosthesis was implanted with bone cement. After 1 to 16 years follow-up, functions of the shoulder joint were reserved in 86% of the patients.

      Release date:2016-09-01 11:08 Export PDF Favorites Scan
    • EXPERIMENTAL STUDY ON TENSILE STRENGTH OF CARBONTENDON IMPLANTEDINTO BONE

      A mechanical study on the bones of 29 rabbits following implantation of carbontendon was carried out. The rabbits were divided into seven groups according to the observation time (2,4,6,8,12,20 and 30 weeks after operation). A bundle of artificial tendon composed of 7,000 carbon fibers was passedthrough a tunnel in the tibia, and both ends of the artificial tendon were ligated to the muscle fibers. The mechanical strength and histological structure of the carbonbone junction and their relationship were studied in each group. Carbon fiberwas split and degradated in six to eight weeks after operation. The tensile strength of carbontendon in the soft tissue was decreased from 82±4.6N in the second week to 27±5.31N and6.3±1.81N in the sixth and eighth week respectively. The tensile strength of carbontendon increased from 3.01±1.2N to 6.1±2.01N at the carbon -tendon-bone junction in the bone. The tensile strength of carbon-tendon was unsatisfactory for implantation into bone. The carbon-tendon was split and degradated and the tensile strength was not b enough to cope with the early functional exercises.

      Release date:2016-09-01 11:10 Export PDF Favorites Scan
    • Observation on Therapeutic Effect of Warfarin on 103 Pregnant Women with Prosthetic Mechanical Heart Valves Throughout Pregnancy

      Abstract: Objective To investigate the anticoagulation effect of warfarin on pregnant women with prosthetic mechanical heart valves during the whole course of pregnancy and their fetuses. Methods Followup survey was carried out on 103 pregnant women with prosthetic mechanical heart valves treated in the Second Xiangya Hospital of Central South University from April 1998 to June 2010. Their age ranged from 19 and 38 years (26.4±3.8 years). All the 103 pregnant women were given oral administration of warfarin during the whole course of pregnancy. The average dose of domestic warfarin was 3.30±0.43 mg/d (87 cases), while the average dose of imported warfarin was 2.90±1.05 mg/d (16 cases). Results None of the patients suffered from serious embolic events. One patient suffered from spontaneous peritoneal hemorrhage. There were 4 cases of intrauterine deaths, and 5 cases of fetal malformation including 1 case of Down’s syndrome and 4 cases of hydrocephalus. Six cases of low birth weight infants and 1 case of ABO hemolytic disease were also found. All the other neonates were healthy with normal weight. No pregnant women suffered from postpartum hemorrhage. Conclusion Oral administration of low dose warfarin (lt;5 mg/d) during the whole course of pregnancy is a relative safe and effective anticoagulation protocol.

      Release date:2016-08-30 05:57 Export PDF Favorites Scan
    • ROLE OF PRE-COATING IN ARTIFICIAL VESSEL ENDOTHELIALIZATION

      Objective To understand the value of pre-coating in artificial vessel endothelialization. Methods Literature concerning precoating in artificial vessel endothelialization was extensively reviewed. Results Pre-coating included chemical coatings(collagen, fibronectin, laminin, poly-l-lysin, gelatin andextracellular matrix), pre-clotting(plasma, blood, serum and fibrin glue), chemical bonding (heparin, RGD and lectins) and surface modification. Most of them could enhance the adhesion of the endothelial cells. Conclusion Pre-coating couldimprove endothelialization, but further research is needed to search for the appropriate concentration and incubation time.

      Release date:2016-09-01 09:29 Export PDF Favorites Scan
    • Screening and diagnostic system construction for optic neuritis and non-arteritic anterior ischemic optic neuropathy based on color fundus images using deep learning

      Objective To construct and evaluate a screening and diagnostic system based on color fundus images and artificial intelligence (AI)-assisted screening for optic neuritis (ON) and non-arteritic anterior ischemic optic neuropathy (NAION). MethodsA diagnostic test study. From 2016 to 2020, 178 cases 267 eyes of NAION patients (NAION group) and 204 cases 346 eyes of ON patients (ON group) were examined and diagnosed in Zhongshan Ophthalmic Center of Sun Yat-sen University; 513 healthy individuals of 1 160 eyes (the normal control group) with normal fundus by visual acuity, intraocular pressure and optical coherence tomography examination were collected from 2018 to 2020. All 2 909 color fundus images were as the data set of the screening and diagnosis system, including 730, 805, and 1 374 images for the NAION group, ON group, and normal control group, respectively. The correctly labeled color fundus images were used as input data, and the EfficientNet-B0 algorithm was selected for model training and validation. Finally, three systems for screening abnormal optic discs, ON, and NAION were constructed. The subject operating characteristic (ROC) curve, area under the ROC (AUC), accuracy, sensitivity, specificity, and heat map were used as indicators of diagnostic efficacy. ResultsIn the test data set, the AUC for diagnosing the presence of an abnormal optic disc, the presence of ON, and the presence of NAION were 0.967 [95% confidence interval (CI) 0.947-0.980], 0.964 (95%CI 0.938-0.979), and 0.979 (95%CI 0.958-0.989), respectively. The activation area of the systems were mainly located in the optic disc area in the decision-making process. ConclusionAbnormal optic disc, ON and NAION, and screening diagnostic systems based on color fundus images have shown accurate and efficient diagnostic performance.

      Release date:2023-02-17 09:35 Export PDF Favorites Scan
    24 pages Previous 1 2 3 ... 24 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南