• <table id="gigg0"></table>
  • west china medical publishers
    Author
    • Title
    • Author
    • Keyword
    • Abstract
    Advance search
    Advance search

    Search

    find Author "陶圣祥" 3 results
    • 封閉式負壓引流聯合前臂皮神經營養血管皮瓣修復手掌皮膚缺損

      總結封閉式負壓引流(vacuum sealing drainage,VSD)聯合前臂皮神經營養血管皮瓣修復手掌皮膚缺損的臨床療效。 方法 2005 年6 月- 2006 年5 月,收治12 例手掌皮膚缺損患者。男7 例,女5 例;年齡17 ~ 45 歲。擠傷3 例,電鋸傷2 例,絞傷4 例,電燒傷1 例,爆炸傷2 例。缺損范圍5 cm × 4 cm ~ 7 cm × 7 cm。采用VSD 待創面肉芽組織新鮮、感染控制后,用前臂內、外側皮神經營養血管皮瓣移位修復手掌皮膚缺損,皮瓣范圍6 cm ×5 cm ~ 8 cm × 8 cm。 結果 術后1 例皮瓣遠端部分壞死,1 例因血腫壓迫出現靜脈危象,經對癥處理后愈合。余患者皮瓣Ⅰ期愈合。供區成活良好。患者獲隨訪4 ~ 15 個月。根據中華醫學會手外科學會功能評定標準:腕關節、掌指關節功能均為優;1 例肌腱功能評分為良,其余為優;感覺評定S1 1 例,S2 2 例,S3 5 例,S3+ 2 例,S4 2 例。 結論 VSD 能減少創面感染機會,為皮瓣修復提供良好組織床。前臂皮神經營養血管皮瓣移位修復手掌部組織缺損,具有耐磨、無攣縮、重建感覺以及色澤與原皮膚相近等優點,是修復手掌部皮膚缺損的良好方法之一。

      Release date:2016-09-01 09:12 Export PDF Favorites Scan
    • Application of composite tissue flaps pedicled with distal perforating branch of posterior tibial artery for repairing distal leg defects

      Objective To investigate the clinical application and effectiveness of the composite tissue flaps pedicled with perforating branch of posterior tibial artery for repairing distal leg defects. Methods Between September 2014 and August 2017, 12 patients with skin and bone defects of distal leg were repaired with the composite tissue flaps pedicled with perforating branch of posterior tibial artery. There were 8 males and 4 females with an average age of 41.3 years (range, 25-66 years). The causes of injury included traffic accident injury in 7 cases, heavy crushing injury in 2 cases, tibial osteomyelitis with soft tissue ulcer and necrosis in 2 cases, and bone and soft tissue defect after resection of bone tumor in 1 case. Eight patients underwent primary repair, and 4 patients underwent second-stage repair. The size ranged from 6 cm×4 cm to 10 cm×7 cm in skin flap, from 4.0 cm×2.5 cm to 8.0 cm×6.0 cm in muscle flap, and from 4 cm×2 cm×2 cm to 5 cm×4 cm×4 cm in tibial bone flap. Tibial defects of the donor region were repaired by autologous iliac bone grafting, and the wounds were sutured directly in 7 cases and repaired by autologous skin grafting in 5 cases. Results All composite tissue flaps survived and both the recipient and the donor wounds healed primarily. All patients were followed up 6-12 months, with an average of 10.8 months. The appearance, color, texture of the composite tissue flaps and ankle function were satisfactory. X-ray films showed that the bone flap at the tibia defect and the ilium graft at the donor site both healed well at 6 months after operation. Conclusion The composite tissue flaps pedicled with perforating branch of posterior tibial artery has abundant blood, and it is a good donor region for repairing the distal leg defects combined with circumscribed bone defect.

      Release date:2019-01-03 04:07 Export PDF Favorites Scan
    • Treatment of severe distal humeral bone defects with three-dimensional printing technology

      ObjectiveTo explore the application of three-dimensional (3D) printing technology in precise and individualized surgical treatment of severe distal humeral bone defect.MethodsFive patients with severe distal humeral bone defects were treated with customized 3D printing prostheses between December 2010 and December 2015. There were 4 males and 1 female, with an age of 23-57 years (mean, 35 years); and the length of the bone defect was 5-12 cm (mean, 8 cm). The cause of injury was mechanical injury in 2 cases and strangulation in 3 cases. All of them were the open fracture of Gustilo type Ⅲ. There were 2 cases of radial fracture, 1 case of cubital nerve injury, and 3 cases of radial nerve injury. The time from injury to one-stage operation was 6-18 hours (mean, 10 hours). The operation time, intraoperative blood loss, and intraoperative fluoroscopy were recorded. During follow-up, the anteroposterior and lateral X-ray films of the elbow joints were performed to identify whether there was prosthesis loosening; Mayo Elbow Performance Score (MEPS) and upper extremity Enneking score were used to evaluate limb function.ResultsThe operation time was 140-190 minutes (mean, 165 minutes). The intraoperative blood loss was 310-490 mL (mean, 415 mL). The intraoperative fluoroscopy was 1-3 times (mean, 1.6 times). Five patients were followed up 14-38 months (mean, 21 months). The wound exudate occurred in 1 case and cured after anti-inflammatory local dressing change; the subcutaneous hematoma occurred in 1 case, and improved after color Doppler ultrasound guided puncture and drainage. The MEPS scores and the Enneking scores were all significantly improved when compared with preoperative ones (P<0.05). Except MEPS score between 6 and 12 months after operation had no significant difference (P>0.05), there were significant differences in MEPS scores and Enneking scores between the other time points (P<0.05). During the follow-up, no prosthetic loosening or joint dislocation occurred.Conclusion3D printing technology can achieve personalized treatment of severe distal humeral bone defects, obtain relatively good elbow joint function, and has less postoperative complications and satisfactory effectiveness.

      Release date:2018-12-04 03:41 Export PDF Favorites Scan
    1 pages Previous 1 Next

    Format

    Content

  • <table id="gigg0"></table>
  • 松坂南