The hydroxyapatite particles were used to repair 23 cases of depressed deformities of face. The patients were follwed up for 3 to 8 months and the short termresults were satisfactory. The operative procedure was briefly introduced. The advantages and attentions relevant to the operation were discussed.
OBJECTIVE: To study the effect of platelet-rich plasma in the repair of bone defect. METHODS: Segmental bone defects of 1 cm were created in the mid-upper part of bilateral radius of 24 New Zealand white rabbits. One side was randomly chosen as the experimental side, which was filled with artificial bone with platelet-rich plasma (PRP). The other side filled with artificial bone without PRP as the control. After 2, 4, 8 and 12 weeks of implantation, the gross, radiological, histological observations, and computer graphic analysis were performed to investigate the bone healing of the defect in both sides. RESULTS: Two weeks after operation, new bone and fibrous tissue formation in both the experimental and the control sides were observed only in the areas adjacent to the cut ends of the host bone, but the amount of new tissue in the experimental side was much more than that in the control side. In the 4th and 8th weeks, the surface of the artificial bone was covered with a large amount of new bones, the artificial bone was bridged tightly with the host bone by callus in the experimental side, while new bone was limited mainly in the cut ends and was less mature in the control side. In the 12th weeks, bone defects were entirely healed in the experimental side, which were covered completely with cortical bone, while new bone formation was only observed in the ends of artificial bone and there were not continuous bone callus on the surface in the control side. CONCLUSION: Artificial bone with PRP is effective in the repair of segmental bone defects, and PRP could improve the healing of bone defect.
Objective To evaluate the biomechanical stability of a newly-designed Y type pedicle screw (YPS) in osteoporotic synthetic bone. Methods The osteoporotic synthetic bone were randomly divided into 3 groups (n=20). A pilot hole, 3.0 mm in diameter and 30.0 mm in deep, was prepared in these bones with the same method. The YPS, expansive pedicle screw (EPS), and bone cement-injectable cannulated pedicle screw (CICPS) were inserted into these synthetic bone through the pilot hole prepared. X-ray film examination was performed after 12 hours; the biomechanical stability of YPS, EPS, and CICPS groups was tested by the universal testing machine (E10000). The test items included the maximum axial pullout force, the maximum running torque, and the maximum periodical anti-bending. Results X-ray examination showed that in YPS group, the main screw and the core pin were wrapped around the polyurethane material, the core pin was formed from the lower 1/3 of the main screw and formed an angle of 15° with the main screw, and the lowest point of the inserted middle core pin was positioned at the same level with the main screw; in EPS group, the tip of EPS expanded markedly and formed a claw-like structure; in CICPS group, the bone cement was mainly distributed in the front of the screw and was dispersed in the trabecular bone to form a stable screw-bone cement-trabecular complex. The maximum axial pullout force of YPS, EPS, and CICPS groups was (98.43±8.26), (77.41±11.41), and (186.43±23.23) N, respectively; the maximum running torque was (1.42±0.33), (0.96±0.37), and (2.27±0.39) N/m, respectively; and the maximum periodical anti-bending was (67.49±3.02), (66.03±2.88), and (143.48±4.73) N, respectively. The above indexes in CICPS group were significantly higher than those in YPS group and EPS group (P<0.05); the maximum axial pullout force and the maximum running torque in YPS group were significantly higher than those in EPS group (P<0.05), but there was no significant difference in the maximum periodical anti-bending between YPS group and EPS group (P>0.05). Conclusion Compared with EPS, YPS can effectively enhance the maximum axial pullout force and maximum rotation force in the module, which provides a new idea for the design of screws and the choice of different fixation methods under the condition of osteoporosis.
Abstract To investigate the ectopic new bone formation following implantation of bovine hydroxyapatite Bio-oss together with free periosteum, 12 chabb: ch rabbits were selected. In 10 rabbits, Bio-oss block together with free periosteum was implanted in the gastrocnemius muscle of one leg randomly, and Bio-oss block alone was implanted in the same muscle of the other leg. In the other 2 rabbits, the periosteum was implanted into the gastrocnemius musle of both legs. Histologic examination and quantitative analysis of newbone formation were performed at 3 and 6 weeks postoperatively. The results showed that in the legs implanted bovine hydroxyapatite Bio-oss together with freeperiosteum, new bone formation began at 5th day after implantation. The area ofnew bone composed of 19.0% of the specimens at 3 weeks postoperatively. No boneformation through out the experimental period in Bio-oss block alone implantedlegs and also periosteum implanted legs. We concluded that bovine hydroxyapatite Bio-oss has a good capacity of osteoconduction. New bone can be formed after the implantation of hydroxyapatite combined with free periosteum.
OBJECTIVE: To study the effect of self-setting calcium phosphate cement (CPC) on the repair of local bone defects after resection of cyst in children. METHODS: From December 1998 to May 2002, 22 patients with bone defects were repaired with CPC. Their ages ranged from 4 to 10 years with an average of 8.3 years. There were 11 cases of non-ossifying fibroma, 7 cases of osteoid osteoma, 2 cases of bone cyst and 2 cases of fibrous dysplasia. The bone defects are located as the following: femur in 14 cases, tibia in 6 cases and humerus in 2 cases. CPC spongiosa granules were filled in 11 cases, injectable CPC were filled in 2 bone cyst cases. The patients were followed up for 5-48 months, averaged 23.5 months. RESULTS: Bone matrix grew well and no recurrence was found. CONCLUSION: The method with simple CPC in repairing bone defects is safe, non-toxic, economic and convenient in children.
Objective To study the effect and complication of repairing depressed fracture of frontal part with hydroxylapatite particulate artificial bone. Methods From January 1994 to December 2002, 13 patients were all diagnosed as having depressed fracture of frontal part with clinical and X-ray examinations. Thesmall incision before the hair-edge or local small incision was made. After opening the incision, we performed creeping decollement. Then the hydroxylapatite particulate artificial bone was implanted into the sites of the depressed fracture. The effect and complication were observed with clinical and X-rayexaminations in all patients 1 week, 1 month, 3 months after operation.Results The quantity of hydroxylapatite implanted was 10-30g. Primary healing was obtained in all cases without any complication. All cases were followed up for 3 months. The contours of the frontal part were restored well. Conclusion It is a good method to repair depressed fracture of frontal part with hydroxylapatite particulate artificial bone.
To investigate the cl inical results and the mechanism of bone heal ing for the repair of bone defects following tumor resection with novel interporous TCP bone graft, and to test the hypothesis of “structural transplantation”. Methods From January 2003 to December 2005, 61 cases of various bone defects following the curettage of the benign bone tumors were treated with interporous TCP, with 33 males and 28 females, including bone fibrous dysplasiain 8 cases, bone cyst in 23 cases, eosinophil ic granuloma in 12 cases, enchondroma in 13 cases, non-ossifying fibroma in 2 cases, and osteoblastoma in 3 cases. Tumor sizes varied from 1.5 cm × 1.0 cm to 7.0 cm × 5.0 cm. The plain X-ray, single photon emission computed tomography (SPECT) and histology examination were obtained at various time points after operation. The in vivo biodegradation rate of the implanted TCP was evaluated based on a semi-quantitive radiographic analyzing method. Histopathology examination was performed in 1 revision case. Results All the patients were followed up for 5 to 24 months after operation. They all had good wound heal ing and bone regeneration. There was neither significant reverse reaction to the transplanted material nor locally inflammatory reaction in all of the cases. The bone defects were repaired gradually from 1 to 6 months after operation (bone heal ing at average 2.6 months after surgery) with a bone heal ing rate up to 96.7%. There was only 1 recurrence case (eosinophil ic granuloma in ischium) 3 months after operation. Given revision operation, this case gained bone heal ing. Radiographically, the interface between the implanted bone and host bone became fuzzy 1 month after implantation, indicating the beginning of new bone formation. Three months later, the absorption of the interporous TCP was noticed from peripheral to the center of the implanted bone evidenced by the vague or fuzzy realm. New bone formation could be seen both in peri pheral and central areas. Six months later, implanted bone and host bone merged together and the bone defect was totally repaired, with 78.9% degradation rate of the implanted TCP. Twelve months later, the majority of the implanted bone was absorbed and bone remodel ing was establ ished. In the cases that were followed up for 24 months, the function of affectedextremity was excellent with good bone remodel ing without recurrence. In 2 cases, SPECT showed that nucl ide uptake could be observed in implanted site and the metabol ic activity was high both in the central as well as the peripheral areas of the graft 1 month after implantation, which was an evidence of osteogenesis. Pathologically, the interporous TCP closely contacted the host bone inside the humerus 1 month after grafting. The interface between the implanted bone and host bone became fuzzy, and vascularized tissue began growing inside the implanted graft as a “l ining” structure. Conclusion The interporous TCP proves to be effective for cl inical reparation of bone defects following tumor resection. The inside three-dimensional porous structure simulates the natural bionic bone structure which is suitable for recruitment related cells in-growth into the scaffold, colonizing and prol iferation companied with the process of vascularize, finally with the new bone formation. The novel interporous TCP may boast both bone conductive and bone inductive activities, as an appeal ing “structural transplantation” bone graft.
The primary results of five patients in whomthe block hydroxyapatite artificial bone (BHAB)used in maxillofacial plastic repair were reported. All incisions healed up with no evidence ofinfection. None of the implants was rejected norhad resorption changes. Satisfactory estheticaleffects were maintained. The results demonst-rated BHAB had a good biocampatibility andcould be used as a bone graft substitute inmaxillofacial plastic repair. This kind of material could be carved and contoured ...
ObjectiveTo study the preparation and properties of the hyaluronic acid (HA)/α-calcium sulfate hemihydrate (α-CSH)/β-tricalcium phosphate (β-TCP) material (hereinafter referred to as composite material). Methods Firstly, the α-CSH was prepared from calcium sulfate dihydrate by hydrothermal method, and the β-TCP was prepared by wet reaction of soluble calcium salt and phosphate. Secondly, the α-CSH and β-TCP were mixed in different proportions (10∶0, 9∶1, 8∶2, 7∶3, 5∶5, and 3∶7), and then mixed with HA solutions with concentrations of 0.1%, 0.25%, 0.5%, 1.0%, and 2.0%, respectively, at a liquid-solid ratio of 0.30 and 0.35 respectively to prepare HA/α-CSH/ β-TCP composite material. The α-CSH/β-TCP composite material prepared with α-CSH, β-TCP, and deionized water was used as the control. The composite material was analyzed by scanning electron microscope, X-ray diffraction analysis, initial/final setting time, degradation, compressive strength, dispersion, injectability, and cytotoxicity. ResultsThe HA/α-CSH/β-TCP composite material was prepared successfully. The composite material has rough surface, densely packed irregular block particles and strip particles, and microporous structures, with the pore size mainly between 5 and 15 μm. When the content of β-TCP increased, the initial/final setting time of composite material increased, the degradation rate decreased, and the compressive strength showed a trend of first increasing and then weakening; there were significant differences between the composite materials with different α-CSH/β-TCP proportion (P<0.05). Adding HA improved the injectable property of the composite material, and it showed an increasing trend with the increase of concentration (P<0.05), but it has no obvious effect on the setting time of composite material (P>0.05). The cytotoxicity level of HA/α-CSH/β-TCP composite material ranged from 0 to 1, without cytotoxicity. Conclusion The HA/α-CSH/β-TCP composite materials have good biocompatibility. Theoretically, it can meet the clinical needs of bone defect repairing, and may be a new artificial bone material with potential clinical application prospect.