| 1. | ?Obora Y, Tamaki N, Matsumoto S. Nonsuture microvascular anastomosis using magnet rings: preliminary report. Surg Neurol, 1978, 9(2): 117-120. | 
				                                                        
				                                                            
				                                                                | 2. | Cope C. Creation of compression gastroenterostomy by means of the oral, percutaneous, or surgical introduction of magnets: feasibil ity study in swine. J Vasc Interv Radiol, 1995, 6(4): 539-545. | 
				                                                        
				                                                            
				                                                                | 3. | Cope C, Ginsberg G. Long-term patency of experimental magnetic compression gastroenteric anastomoses achieved with covered stents. Gastrointest Endosc, 2001, 53(7): 780-784. | 
				                                                        
				                                                            
				                                                                | 4. | Jamshidi R, Stephenson JT, Clay JG, et al. Magnamosis: magnetic compression anastomosis with comparison to suture and staple techniques. J Pediatr Surg, 2009, 44(1): 222-228. | 
				                                                        
				                                                            
				                                                                | 5. | Pichakron KO, Jelin EB, Hirose S, et al. Magnamosis Ⅱ: magnetic compression anastomosis for minimally invasive gastrojejunostomy and jejunojejunostomy. J Am Coll Surg, 2011, 212(1): 42-49. | 
				                                                        
				                                                            
				                                                                | 6. | Gonzales KD, Douglas G, Pichakron KO, et al. Magnamosis Ⅲ: del ivery of a magnetic compression anastomosis device using minimally invasive endoscopic techniques. J Pediatr Surg, 2012, 47(6): 1291-1295. | 
				                                                        
				                                                            
				                                                                | 7. | 侯鄭生, 劉京山, 趙期康, 等. 磁鐵壓迫吻合術治療腸梗阻動物實驗研究. 中國現代普通外科進展, 2009, 12(8): 649-652. | 
				                                                        
				                                                            
				                                                                | 8. | Ryou M, Cantillon-Murphy P, Azagury D, et al. Smart Self-Assembling MagnetS for ENdoscopy (SAMSEN) for transoral endoscopic creation of immediate gastrojejunostomy (with video). Gastrointest Endosc, 2011, 73(2): 353-359. | 
				                                                        
				                                                            
				                                                                | 9. | 西安交通大學. 一種組合式磁性吻合器: 中國, 201310574578.1[P]. 2014-03-05. | 
				                                                        
				                                                            
				                                                                | 10. | 西安交通大學. 一種載藥性的可降解的磁吻合器: 中國, 201310574009.1[P]. 2014-03-05. | 
				                                                        
				                                                            
				                                                                | 11. | Diana M, Mutter D, Lindner V, et al. A modular magnetic anastomotic device for minimally invasive digestive anastomosis: proof of concept and prel iminary data in the pig model. Surg Endosc, 2014, 28(5): 1613-1623. | 
				                                                        
				                                                            
				                                                                | 12. | Saveliev VS, Avaliani MV, Bashirov AD. Endoscopic magnetic cholecystodigestive anastomoses: personal technique for pall iative treatment of distal bile duct obstruction. J Laparoendosc Surg, 1993, 3(2): 99-112. | 
				                                                        
				                                                            
				                                                                | 13. | 山內榮五郎. 消化道介入放射學療法新進展--磁鐵壓迫吻合術(三內法). 日本醫學介紹, 2001, 22(2): 76-79. | 
				                                                        
				                                                            
				                                                                | 14. | Yamanouchi E, Kumano R, Kobayashi K, et al. Treatment for bowel or bil iary obstruction by magnetic compression anastomosis development of Yamanouchi's method and its cl inical evaluation. J Nippon Med Sc, 2002, 69(5): 471-475. | 
				                                                        
				                                                            
				                                                                | 15. | Mimuro A, Tsuchida A, Yamanouchi E, et al. A novel technique of magnetic compression anastomosis for severe bil iary stenosis. Gastrointest Endosc, 2003, 58(2): 283-287. | 
				                                                        
				                                                            
				                                                                | 16. | Itoi T, Yamanouchi E, Ikeda T, et al. Magnetic compression anasto mosis: a novel technique for canalization of severe hilar bile duct strictures. Endoscopy, 2005, 37(12): 1248-1251. | 
				                                                        
				                                                            
				                                                                | 17. | Akita H, Hikita H, Yamanouchi E, et al. Use of a metallic-wall stent in the magnet compression anastomosis technique for bile duct obstruction after liver transplantation. Liver Transpl, 2008, 14(1): 118-120. | 
				                                                        
				                                                            
				                                                                | 18. | Itoi T, Yamanouchi E, Ikeuchi N, et al. Magnetic compression duct-toduct anastomosis for bil iary obstruction in a patient with living donor liver transplantation. Gut Liver, 2010, 4 Suppl 1: S96-S98. | 
				                                                        
				                                                            
				                                                                | 19. | Li J, Lü Y, Qu B, et al. Application of a new type of sutureless magnetic bil iary-enteric anastomosis stent for one-stage reconstruction of the bil iary-enteric continuity after acute bile duct injury: an experimental study. J Surg Res, 2008, 148(2): 136-142. | 
				                                                        
				                                                            
				                                                                | 20. | Fan C, Yan XP, Liu SQ, et al. Roux-en-Y choledochojejunostomy using novel magnetic compressive anastomats in canine model of obstructive jaundice. Hepatobiliary Pancreat Dis Int, 2012, 11(1): 81-88. | 
				                                                        
				                                                            
				                                                                | 21. | Avaliani M, Chigogidze N, Nechi pai A, et al. Magnetic compression bil iary-enteric anastomosis for pall iation of obstructive jaundice: initial cl inical results. J Vasc Interv Radiol, 2009, 20(5): 614-623. | 
				                                                        
				                                                            
				                                                                | 22. | Jamidar P, Cadeddu M, Mosse A, et al. A hinged metalloplastic anastomotic device: a novel method for choledochoduodenostomy. Gastrointest Endosc, 2009, 69(7): 1333-1338. | 
				                                                        
				                                                            
				                                                                | 23. | Jang SI, Kim JH, Won JY, et al. Magnetic compression anastomosis is useful in bil iary anastomotic strictures after living donor liver transplantation. Gastroint Endosc, 2011, 74(5): 1040-1048. | 
				                                                        
				                                                            
				                                                                | 24. | Lambe T, Ríordáin MG, Cahill RA, et al. Magnetic compression in gastrointestinal and bil ioenteric anastomosis: how much force? Surg Innov, 2014, 21(1): 65-73. | 
				                                                        
				                                                            
				                                                                | 25. | MAGDA: Magnetic force Determination Algorithm[EB/OL] (2012-01-01)[2014-04-12]. http://magda.ucc.ie. | 
				                                                        
				                                                            
				                                                                | 26. | Erdmann D, Sweis R, Heitmann C, et al. Side-to-side sutureless vascular anastomosis with magnets. J Vasc Surg, 2004, 40(3): 505-511. | 
				                                                        
				                                                            
				                                                                | 27. | Klima U, MacVaugh H, Bagaev E, et al. Magnetic vascular port in minimally invasive direct coronary artery bypass grafting. Circulation, 2004, 110(11 suppl 1): Ⅱ55-Ⅱ60. | 
				                                                        
				                                                            
				                                                                | 28. | Vicol C, Eifert S, Oberhoffer M, et al. Early cl inical results with a magnetic connector for distal coronary artery anastomoses. Ann Thorac Surg, 2005, 79(5): 1738-1742. | 
				                                                        
				                                                            
				                                                                | 29. | Shi Y, Lv Y, Wang B, et al. Novel magnetic rings for rapid vascular reconstruction in canine liver transplantation model. Transplant Proc, 2006, 38(9): 3070-3074. | 
				                                                        
				                                                            
				                                                                | 30. | Zaritzky M, Ben R, Zylberg GI, et al. Magnetic compression anastomosis as a nonsurgical treatment for esophageal atresia. Pediat Radiol, 2009, 39(9): 945-949. | 
				                                                        
				                                                            
				                                                                | 31. | Ryou M, Cantillon-Murphy P, Shaikh SN, et al. Magnetic pancreaticobil iary stents and retrieval system: obviating the need for repeat endoscopy (with video). Gastrointest Endosc, 2012, 75(4): 888-892. e1. | 
				                                                        
				                                                            
				                                                                | 32. | Ganz RA, Peters JH, Horgan S, et al. Esophageal sphincter device for gastroesophageal reflux disease. N Engl J Med, 2013, 368(8): 719-727. | 
				                                                        
				                                                            
				                                                                | 33. | Chung H, Dhumane P, Liu KH, et al. Endoscopic submucosal dissection with a novel traction method using a steerable grasper: a feasibility study in a porcine model. Surg Innov, 2013, 21(1): 5-10. |